Remote Insight Command Language
277
PASSWORD is the password associated with the user. This parameter is case
sensitive and can be a combination of any printable characters. The length is user
defined and can be a minimum of zero characters and a maximum of 39
characters. The minimum length is defined in the iLO Global Settings and has a
default value of eight characters.
ADMIN_PRIV is a Boolean parameter that allows the user to administer user
accounts. The user can modify their account settings, modify other user account
settings, add users, and delete users. Omitting this parameter prevents the user
from adding, deleting, or configuring user accounts.
REMOTE_CONS_PRIV is a Boolean parameter that gives permission for the
user to access the Remote Console functionality. This parameter is optional, and
the Boolean string must be set to "Yes" if the user should have this privilege. If
this parameter is used, the Boolean string value must never be left blank.
Omitting this parameter denies the user access to Remote Console functionality.
RESET_SERVER_PRIV is a Boolean parameter that gives the user permission
to remotely manipulate the server power setting. This parameter is optional, and
the Boolean string must be set to "Yes" if the user should have this privilege. If
this parameter is used, the Boolean string value must never be left blank.
Omitting this parameter prevents the user from manipulating the server power
settings.
VIRTUAL_MEDIA_PRIV is a Boolean parameter that gives the user permission
to access the virtual media functionality. This parameter is optional, and the
Boolean string must be set to "Yes" if the user should have this privilege. If this
parameter is used, the Boolean string value must never be left blank. Omitting
this parameter denies the user virtual media privileges.
CONFIG_ILO_PRIV is a Boolean parameter that allows the user to configure
iLO settings. This privilege includes network settings, global settings, Insight
Manager settings, and SNMP settings. This parameter is optional, and the
Boolean string must be set to "Yes" if the user should have this privilege. If this
parameter is used, the Boolean string value must never be blank. Omitting this
parameter prevents the user from manipulating the current iLO configuration.
The following parameters are not applicable to a user's privileges in the iLO
firmware versions 1.40 and higher. The parameters will parse correctly, but user
privileges will not be affected.