User Guide Integrated Lights-Out
Be sure that the Lights-Out Configuration Utility is in a directory referenced by
the PATH environment variable. Any log files generated are placed in the same
directory as the Lights-Out Configuration Utility executable
The switches -L and -V might or might not be set depending on the
IT administrator's preferences.
Refer to the "Remote Insight Command Language (on page 269)" section for
information on the syntax of the XML data files. Sample XML scripts are
available on the HP website (http://www.hp.com/servers/lights-out) in the Best
Practices section.
-F is the switch that gives the full path location and name of the RIBCL file
that contains the actions to be performed on the board.
-U and -P specify the user login name and password.
-L is the switch that defines where the log file will be generated and what the
file name will be. If this switch is omitted, a default log file with the DNS
name or the IP address is created in the same directory used to launch
CPQLOCFG.
Do not use this switch if launching from Insight Manager 7 or Systems
Insight Manager.
NOTE: The -L parameter cannot designate an output log file. A default
log file named with the DNS name or the IP address is created in the
same directory where CPQLOCFG is launched.
-V is the optional switch that turns on the verbose message return. The
resulting log file contains all commands sent to the Remote Insight board, all
responses from the Remote Insight board, and any errors. By default, only
errors and responses from GET commands are logged without this switch.