HP ProLiant BL280c - G6 Server Datasheet
HP ProLiant BL280c - G6 Server Datasheet

HP ProLiant BL280c - G6 Server Datasheet

Hp insight management wbem providers for hp integrated vmware esxi data sheet
Hide thumbs Also See for ProLiant BL280c - G6 Server:
Table of Contents

Advertisement

HP Insight Management WBEM Providers for
HP integrated VMware ESXi
Data Sheet
Part number 574748-003
Third Edition March 2010

Advertisement

Table of Contents
loading

Summary of Contents for HP ProLiant BL280c - G6 Server

  • Page 1 HP Insight Management WBEM Providers for HP integrated VMware ESXi Data Sheet Part number 574748-003 Third Edition March 2010...
  • Page 2 © Copyright 2009, 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty.
  • Page 3: Table Of Contents

    Contents Overview ..........................13 Ethernet port ..........................14 Overview ............................14 Namespaces ..........................14 Class implementations ........................14 2-3-1 SMX_EthernetPort ......................... 15 2-3-2 SMX_EthernetDevice ......................17 2-3-3 SMX_EthernetLANEndpoint ....................18 2-3-4 SMX_EthernetLANHostedAccessPoint ..................19 2-3-5 SMX_EthernetPortToLANEndpoint ................... 19 2-3-6 SMX_EthernetPortController ....................20 2-3-7 SMX_EthernetPortControllerEthernetPort ...................
  • Page 4 Smart Array ..........................46 Overview ............................46 Use cases ............................46 Class implementations ........................46 4-3-1 SMX_SAArraySystem ......................46 4-3-2 SMX_SAArrayController ......................48 4-3-3 SMX_SAStorageVolume ......................49 4-3-4 SMX_SADiskDrive ......................... 51 4-3-5 SMX_SAStorageExtent ......................52 4-3-6 SMX_SADiskDriveFirmware ....................53 4-3-7 SMX_SAPhysicalPackage ......................
  • Page 5 4-3-51 SMX_SAArraySystemPortController (Association) ..............81 4-3-52 SMX_SAArraySystemDiskDrive (Association) ................81 4-3-53 SMX_SAArraySystemStorageVolume (Association) ..............82 4-3-54 SMX_SAArraySystemStorageExtent (Association) ..............82 4-3-55 SMX_SAArraySystemDAPort (Association) ................82 4-3-56 SMX_SAArraySystemPrimordialPool (Association) ..............82 4-3-57 SMX_SAArraySystemStoragePool (Association) ................ 82 4-3-58 SMX_SAComputerSystemArraySystem (Association) ..............83 4-3-59 SMX_SAArraySystemArrayController (Association) ..............
  • Page 6 4-4-11 HP_DeviceIndication: Controller Redundancy has been lost ............. 115 4-4-12 HP_DeviceIndication: Controller Redundancy has been restored ..........117 4-4-13 HP_DeviceIndication: Controller Battery Status Change - OK ........... 119 4-4-14 HP_DeviceIndication: Controller Battery status changed to not fully charged ......122 4-4-15 HP_DeviceIndication: Controller Battery status changed to Failed ..........
  • Page 7 6-1-27 SMX_SASStorageEnclosureProcessor ..................178 6-1-28 SMX_SASStorageEnclosureLocation ..................179 6-1-29 SMX_SASDriveCageDiskDrive (Association) ................180 6-1-30 SMX_SASStorageEnclosureDriveCage (Association) ............... 180 6-1-31 SMX_SASStorageEnclosureEnclosureLocation (Association) ............. 180 6-1-32 SMX_SASArraySystemStorageEnclosureProcessor (Association) ..........180 6-1-33 SMX_SASStorageEnclosureProcessorEnclosureFirmware (Association) ........181 6-1-34 SMX_SASStorageEnclosureStorageEnclosureProcessor (Association) ........181 6-1-35 SMX_SASStorageVolumeStorageSetting (Association) ............181 6-1-36 SMX_SASPrimordialPoolStorageCapabilities (Association) ............
  • Page 8 6-2-10 Enclosure Power Supply status changed to Non Redundant ............. 208 6-2-11 Enclosure Power Supply Status changed to OK (Redundant) ............ 210 6-2-12 Enclosure Power Supply Status changed to Redundant Degraded ..........212 6-2-13 Enclosure Temperature sensor Status changed to OK .............. 214 6-2-14 Enclosure Temperature sensor status changed to Warning ............
  • Page 9 8-3-17 SMX_ProcessorLocation ....................... 262 8-3-18 SMX_ProcessorElementLocation .................... 264 Supported indications ........................264 8-4-1 HP_DeviceIndication: Processor Failed Post ................265 8-4-2 HP_DeviceIndication: Processor Disabled by BIOS or EFI ............266 8-4-3 HP_DeviceIndication: Processor Predicted to fail ..............267 System Fan ..........................268 Overview .............................
  • Page 10 10-3-10 SMX_PowerSupplyElementLocation ................294 10-3-11 SMX_PowerSupplyModule ..................296 10-3-12 SMX_SystemPhysicalPowerSupply ................297 10-3-13 SMX_RealizesPowerSupply ..................297 10-3-14 SMX_PowerSupplySlot ....................297 10-3-15 SMX_SystemPowerSupplySlot ..................298 10-3-16 SMX_PowerSupplyInSlot .................... 299 10-3-17 SMX_PowerControllerFirmware .................. 299 10-3-18 SMX_PowerControllerElementFirmwareIdentity ............. 300 10-3-19 SMX_PowerControllerInstalledFirmwareIdentity ............300 10-3-20 SMX_PowerMeter .....................
  • Page 11 13-2-6 SMX_MemoryModuleSlot ....................336 13-2-7 SMX_MemoryBoardSlot....................... 338 13-2-8 SMX_MemoryModuleInSlot ....................340 13-2-9 SMX_MemoryBoardInSlot ....................340 13-2-10 SMX_MemoryModuleSlotOnBoard ................340 13-2-11 SMX_MemoryModuleSlotLocation ................341 13-2-12 SMX_MemoryBoardSlotLocation ................. 342 13-2-13 SMX_MemoryModuleSlotElementLocation ..............343 13-2-14 SMX_MemoryBoardSlotElementLocation ..............344 13-2-15 SMX_SystemMemoryModule ..................344 13-2-16 SMX_SystemMemoryBoard ..................
  • Page 12 15-3-15 SMX_FCHBAComputerSystemSoftwareIdentityDrv ............373 15-3-16 SMX_FCHBAFCPortFCPortStatistics ................373 15-3-17 SMX_FCHBAFCPortLogicalPortGroup ................374 15-3-18 SMX_FCHBAPortControllerFCPort ................374 15-3-19 SMX_FCHBAPhysicalPackagePortController ..............374 15-3-20 SMX_FCHBASoftwareIdentityDrvPortController ............. 375 15-3-21 SMX_FCHBAPortControllerFirmwareIdentityFW ............375 15-3-22 SMX_FCHBAPortControllerFirmwareIdentityBIOS ............376 15-3-23 SMX_FCHBAProductPhysicalComponent ..............376 15-3-24 SMX_FCHBASystemPackaging ................... 376 15-3-25 SMX_FCHBAGroupHostedCollection ................
  • Page 13: Overview

    Overview The HP Insight Management WBEM Providers supply system management data through HP integrated VMware ESXi framework for HP ProLiant server platforms and options. These providers implement the profiles and data described in this document. Use of the providers requires HP integrated VMware ESXi. Overview 13...
  • Page 14: Ethernet Port

    Ethernet port Overview The following profiles are implemented, and files are installed by this provider. Table 2-1 Overview Implemented Profiles • DMTF: Ethernet Port Profile (DSP1014) v. 1.0.0 • DMTF: Host LAN Network Port Profile (DSP1035)1.0.0 • HP Location Profile 1.0 •...
  • Page 15: Smx_Ethernetport

    • SMX_RemoteAccessAvailableToIPEndpoint • SMX_RemoteServiceHostedAccessPoint • SMX_EthernetStatistics • SMX_EthernetPortToStatisticalData • SMX_EthernetPortControllerSoftwareIdentity • SMX_EthernetPortControllerFirmwareIdentity • SMX_EthernetElementSoftwareIdentity • SMX_EthernetElementFirmwareIdentity • SMX_EthernetCollection • SMX_EthernetMemberOfCollection • SMX_EthernetGroupHostedCollection SMX_EthernetPort 2-3-1 SMX_EthernetPort implements the class HP_EthernetPort and describes capabilities and characteristics of each EthernetPort in a monitored system. Table 2-2 Class: SMX_EthernetPort Property name...
  • Page 16 Table 2-2 Class: SMX_EthernetPort StatusDescriptions StatusDescriptions [0] per OperationalStatus[0]: • Unknown • • Degraded • Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice CreationClassName SMX_EthernetPort DeviceID HPQ:SMX_EthernetPort:<InstanceNum> IdentifyingDescriptions None or HPQ: Spare part number if available OtherIdentifyingInfo None or part number text if available SystemName...
  • Page 17: Smx_Ethernetdevice

    Table 2-2 Class: SMX_EthernetPort PortType 0 (Unknown) 1 ( Other) 50 (10BaseT) 51 (10-100BaseT) 52 (100BaseT) 53 (1000BaseT) 54 (2500BaseT) 55 (10GbaseT) 56 (10Gbase-CX4) 100 (100Base-FX) 101 (100Base-SX) 102 (1000Base-SX) 103 (1000Base-LX) 104 (1000Base-CX) 105 (10Gbase_SR) 106 (10Gbase_SW) 107 (10Gbase_LX4) 108 (10Gbase_LR) 109 (10Gbase_LW) 110 (10Gbase_ER)
  • Page 18: Smx_Ethernetlanendpoint

    Table 2-3 Class: SMX_EthernetDevice Property name Property implementation HP_EthernetDevice GroupComponent ref: SMX_ComputerSystem (the computer system in which this Ethernet Port resides) PartComponent ref: SMX_EthernetPort (the instance of Ethernet Port in this ComputerSystem) SMX_EthernetLANEndpoint 2-3-3 SMX_EthernetLANEndpoint implements the class HP_EthernetLANEndpoint and describes a communication endpoint which, when its associate interface is connected to a LAN, might send and receive data frame.
  • Page 19: Smx_Ethernetlanhostedaccesspoint

    Table 2-4 Class: SMX_EthernetLANEndpoint Property name Property implementation SystemCreationClassName SMX_ComputerSystem CIM_ProtocolEndpoint Description Text representing of what the operating system labels this endpoint. For example: eth3 On Windows operating systems: Local Area Connection 2 ElementName LAN Endpoint info for OS Exposed Ethernet Port informatiom.
  • Page 20: Smx_Ethernetportcontroller

    Table 2-6 Class: SMX_EthernetLANHostedAccessPoint Property name Property implementation CIM_Dependency CIM_DeviceSAPImplementation HP_EthernetPortToLANEndpoint Antecedent ref: SMX_EthernetPort Dependent ref: SMX_EthernetPortLANEndpoint SMX_EthernetPortController 2-3-6 SMX_EthernetPortController implements the class HP_BladeEnclosureFW and is a logical device corresponding to a hardware Ethernet network controller. Table 2-7 Class: SMX_EthernetPortController Property name Property implementation CIM_ManagedElement...
  • Page 21: Smx_Ethernetportcontrollerethernetport

    Table 2-7 Class: SMX_EthernetPortController Property name Property implementation ControllerType 2 (Ethernet) ControllerVersion Hardware revision number of the controller or 0 if unknown SMX_EthernetPortControllerEthernetPort 2-3-7 SMX_PortControllerEthernetPort implements the class HP_PortControllerEthernetPort and associates an Ethernet Port Controller to its controlled Ethernet Ports. Table 2-8 Class: SMX_EthernetPortControllerEthernetPort Property name...
  • Page 22: Smx_Ethernetcontrollerphysicalpackageethernetcontroller

    Table 2-9 Class: SMX_EthernetPortControllerPhysicalPackage Property name Property implementation CanBeFRUed Boolen describing if this individual physical package can be replaced in the field. • True if PCI card • False if embedded device on Motherboard CreationClassName SMX_EthernetPortControllerPhysicalPackage Description Product Name For example: Controller (<num_ports>-port): Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21)
  • Page 23: Smx_Ethernetcontrollerlocation

    SMX_EthernetControllerLocation 2-3-10 SMX_EthernetControllerLocation implements the class HP_EthernetControllerLocation. It describes the location information of the Ethernet Contoller Physical Package or card. Table 2-11 Class: SMX_EthernetControllerLocation Property name Property implementation CIM_ManagedElement ElementName Product Name. For Example: 2 port controller: Broadcom Corporation NetXtreme BCM5753M Gigabit Ethernet PCI Express (rev 21) CIM_Location Name...
  • Page 24: Smx_Ethernetcontrollerphysicalpackageethernetcontrollerlocation

    Table 2-11 Class: SMX_EthernetControllerLocation Property name Property implementation LocationInfoDesc Array of enums describing values at comparable index in LocationInformation array. LocationInfoDesc[0] per LocationInfornation[0]. Values for embedded devices: • 17 (Embedded) non-blade, non-cellular system & visible RJ45 • 14 (Blade Bay) for blades with LAN on Motherboard •...
  • Page 25 Table 2-13 Class: SMX_IPProtocolEndpoint Property name Property implementation CIM_ManagedElement ElementName IP Protocol Endpoint info for OS Exposed Ethernet Port informatiom. For example: IP Protocol Endpoint(<instanceNum>) for : 82546GB Gigabit Ethernet Controller port <portNumber> For ESXi, IP Protocol Endpoint information for management network logical interface name.
  • Page 26 Table 2-13 Class: SMX_IPProtocolEndpoint Property name Property implementation AddressOrigin How the Address was assigned to this IP Protocol Endpoint. • 0 (Unknown) • 3 (Static) • 4 (DHCP) IPv4Address Only initialized if IP interface advertises a valid IPv4 Address. IPv6Address Only initialized if IP interface advertises a valid IPv6 Address.
  • Page 27: Smx_Ipbindstoethernetlanendpoint

    SMX_IPBindsToEthernetLANEndpoint 2-3-13 SMX_IPBindsToEthernetLANEndpoint implements the class HP_IPBindsToEthernetLANEndpoint and associates an instance of an IP ProtocolEndpoint with its representative Ethernet LAN Endpoint instance. NOTE: Currently not implemented on VMware ESXi platform. The association information between IP addresses and physical NICs is not available to OEM providers on ESXi. Table 2-14 Class: SMX_IPBingsToEthernetLANEndpoint Property name...
  • Page 28: Smx_Ethernetremoteaccessavailabletoipendpoint

    Table 2-16 Class: SMX_RemoteServiceAccessPoint Property name Property implementation CIM_ManagedElement ElementName A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for <interface_name> CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement CIM_ServiceAccessPoint CreationClassName SMX_RemoteServiceAccessPoint Name A unique description of the gateway, for example: RemoteServiceAccessPoint: Gateway for <interface_name>...
  • Page 29: Smx_Ethernetremoteservicehostedaccesspoint

    Table 2-17 Class: SMX_RemoteAccessAvailableToIPEndpoint Property name Property implementation CIM_RemoteAccessAvailableToElement IsDefault Boolean true if only one default and only one gateway are present. In some systems, you might have order of access constraints if multiple gateways are present. Check OrderOfAccess property for gateway priorities. OrderOfAccess 0 (default) indicates ordering does not apply, othewise numbers indicate priority order of access.
  • Page 30: Smx_Ethernetportstatisticaldata

    Table 2-19 Class: SMX_EthernetStatistics Property name Property implementation Caption For Ethernet Ports, same as associated EthernetPort.Caption. Description A description of the instance with unique port number for each port on a particular controller, for example: Ethernet port <PortNumber> on ethernet controller <controller_id>...
  • Page 31: Smx_Ethernetportcontrollersoftwareidentity

    Table 2-20 Class: SMX_EthernetPortStatisticalData Property name Property implementation CIM_ElementStatisticalData Key:ManagedElement ref:SMX_EthernetPort Key:Stats ref:SMX_EthernetStatistics HP_EthernetPortStatisticalData SMX_EthernetPortControllerSoftwareIdentity 2-3-20 SMX_EthernetPortControllerSoftwareIdentity implements the class CIM_SoftwareIdentity. It represents the adapter driver software of the associated Ethernet Port. NOTE: Currently implemented only on VMware ESXi platform. Table 2-21 Class: SMX_EthernetPortControllerSoftwareidentity Property name...
  • Page 32: Smx_Ethernetelementsoftwareidentity

    Table 2-22 Class: SMX_EthernetPortControllerFirmwareIdentity Property name Property implementation CIM_ManagedElement Caption Ethernet Port Controller Firmware Description Ethernet Port Controler Firmware details for Model Name, where Model name is the Model name of the Ethernet Adapter. ElementName PCI Vendor Id: Device Id CIM_ManagedSystemElement Name Ethernet Port Controler Firmware details for Model...
  • Page 33: Smx_Ethernetelementfirmwareidentity

    SMX_EthernetElementFirmwareIdentity 2-3-23 SMX_EthernetElementFirmwareIdentity implements the class CIM_ElementSoftwareIdentity. It represents the association between SMX_EthernetPortController and SMX_EthernetPortControllerFirmwareIdentity. Table 2-24 Class: SMX_EthernetElementFirmwareIdentity Property name Property implementation CIM_ Dependency Antecedent ref:SMX_EthernetPortControllerFirmwareIdentity Dependent ref:SMX_EthernetPortController CIM_ElementSoftwareIdentity ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_EthernetCollection 2-3-24 SMX_EthernetCollection implements the class HP_EthernetCollection. It represents the collection of all Ethernet Ports.
  • Page 34: Smx_Ethernetmemberofcollection

    SMX_EthernetMemberOfCollection 2-3-25 SMX_EthernetMemberOfCollection associates Ethernet Ports to the Ethernet Collection. Table 2-26 Class: SMX_EthernetMemberofCollection Property name Property implementation CIM_ MemberOfCollection Collection ref:SMX_EthernetCollection Member ref:SMX_EthernetPort CIM_MemberOfPolicyCollection Included Writeable boolean property indicating if the ethernet port instance referenced by Member will contribute status to the SMX_EthernetCollection.
  • Page 35 Table 2-28 Class: Provider Indication Common Properties Property name Property implementation IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. For example, 01.05.00 NetworkAddresses Contains a list of all the IP addresses of the computer...
  • Page 36 Table 2-29 HP_AlertIndication: Network Interface Connectivity Lost Property name Property implementation AlertType 2 (Communications Alert) EventID ProviderName HP Ethernet RecommendedActions View the Ethernet Port status in HP Systems Insight Manager (SIM). View the System Event Log for additional information. HP_AlertIndication Summary The Network interface has lost connectivity.
  • Page 37 Table 2-30 HP_AlertIndication: Network Interface Connectivity Restored Property name Property implementation ProbableCauseDescription Network Interface Connectivity Restored Ethernet port 37...
  • Page 38: Pci Device Provider

    PCI Device Provider Overview This provider implements the profiles listed to support PCI devices installed in HP servers. The following table details the profiles implemented and files installed by this provider. Table 3-1 Overview Implemented Profiles • DMTF: PCI Device Profile (DSP1075) 1.0.0a 09/2007 •...
  • Page 39 Table 3-2 Class: SMX_PCIDevice Property name Property implementation CreationClassName SMX_PCIDevice DeviceID Unique identifier for this PCI device instance SystemCreationClassName SMX_ComputerSystem.CreationClassName SystemName SXM_ComputerSystem.Name CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_PCIController Capabilities An array of integers that indicates controller capabilities.
  • Page 40: Smx_Pcicard

    Table 3-2 Class: SMX_PCIDevice Property name Property implementation CacheLineSize Specifies the system cache line size. CIM_PCIDevice DomainNumber The domain/segment number where this PCI device resides. BusNumber The bus number where this PCI device resides DeviceNumber The device number assigned to this PCI device for the FunctionNumber The function number for this PCI device PCIDeviceID...
  • Page 41: Smx_Pcislot

    Table 3-3 Class: SMX_PCICard Property name Property implementation Description PCI Card <cardNum> ElementName PCI Card <cardNum> CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) PackageType 9 (Module/Card) VendorCompatibilityStrings HPQ:PCICard CIM_Card HostingBoard False HP_PCISlotCard SMX_PCISlot 3-3-3 SMX_PCISlot represents PCI device slots on HP Servers. There is an instance of this class for each PCI slot in the system (whether the slot is occupied or not).
  • Page 42 Table 3-4 Class: HP_PCISlot Property name Property implementation PoweredOn True —If slot is powered on False—If slot is not powered CIM_PhysicalConnector ConnectorLayout 7 (Slot) ConnectorPinout PCI—If 33 MHz PCI slot PCI-66—If 66 MHz PCI slot PCI-X—If PCI-X slot PCI Express—If PCI Express slot PCI Express Mezzanine—If in-blade Mezzanine slot ConnectorType 43 (PCI)—If this is a 33 MHz PCI slot...
  • Page 43: Smx_Pcicardinslot

    SMX_PCICardInSlot 3-3-4 SMX_PCICardInSlot is used to represent an association between SMX_PCICard and SMX_PCISlot that contains this PCI card. Table 3-5 Class: SMX_PCICardInSlot Property name Property implementation Antecedent References SMX_PCISlot Dependent References SMX_PCICard SMX_RealizesPCIDevice 3-3-5 SMX_RealizesPCIDevice is used to represent an association between SMX_PCIDevice and SMX_PCICard that realizes this PCI device.
  • Page 44: Smx_Pcislotlocation

    SMX_PCISlotLocation 3-3-8 SMX_PCISLotLocation is used to model PCI slot locations on HP Servers. The Windows specific implementation class is SMX_PCISlotLocation. Table 3-9 Class: SMX_PCISlotLocation Property name Property implementation CIM_ManagedElement Caption Same as ElementLocationTag. Description Same as ElementLocationTag. ElementName Same as ElementLocationTag. CIM_Location Name Unique identifier of the form:...
  • Page 45: Smx_Pcislotelementlocation

    Table 3-9 Class: SMX_PCISlotLocation Property name Property implementation LocationInfoDesc for BladeSystem servers Array of enumerated values describing context of information at comparable index in LocationInformation array 0 & 1. LocationInfoDesc[0] per LocationInfornation[0]. Blade servers 1 (Mezzanine Slot) 14 (Blade) LocationInfoDesc for all other servers Array of enumerated values describing context of information at comparable index in LocationInformation array 0.
  • Page 46: Smx_Saarraysystem

    Smart Array Overview The HP Smart Array data sheet describes both host based Smart Array HBAs and externally attached MSA enclosures, such as MSA60/70. NOTE: This provider excludes externally attached MSA controllers, such as MSA500 and fibre attached devices, for example MSA1000 or MSA The following profiles are implemented, and the following files are installed by this provider.
  • Page 47 Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name Property implementation ElementName Controller/Storage System name and location Examples: Smart Array in Slot=3, for internal Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement OperationalStatus[0] Overall status of the Array System and attached devices.
  • Page 48: Smx_Saarraycontroller

    Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name Property implementation Dedicated Dedicated[0]: 3 (Storage) Dedicated[1]: 15 (Block Server) IdentifyingDescriptions Other Vendor Specific Name OtherIdentifyingInfo Controller Serial Number Note: EMBEDDED-<id> is reported if there is no Serial Number for device is local i.e embedded on motherboard.
  • Page 49: Smx_Sastoragevolume

    Table 4-3 Class: SMX_SAArrayController (CIM_ComputerSystem) Property name Property implementation Name Controller Serial Number Note: EMBEDDED-<id> is reported if there is no Serial Number for device is local i.e embedded on motherboard. PCISLO-<Slot number> is reported if there is no Serial Number for device is local.
  • Page 50 Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description (for example, Logical Volume 1 (RAID 1+0) CIM_ManagedSystemElement Name VPD Pg83 identifier for the volume. CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice...
  • Page 51: Smx_Sadiskdrive

    Table 4-4 Class: SMX_SAStorageVolume (CIM_StorageVolume) Property name Property implementation Deleteable See HP Smart Array Profile FaultTolerance See HP Smart Array Profile OperationalStatus[0, 1] Volume status. DMTF defined value is populated in index[0] and extended status is poplulated in index[1] per HP Smart Array Profile. OSName Corresponding OS name for this volume.
  • Page 52: Smx_Sastorageextent

    Table 4-5 Class: SMX_SADiskDrive (CIM_DiskDrive) Property name Property implementation HPSA_DiskDrive DriveConfiguration See HP Smart Array Profile DriveHasMNPData See HP Smart Array Profile DriveInterface See HP Smart Array Profile DrivePlacement See HP Smart Array Profile DriveRotationalSpeed See HP Smart Array Profile NegotiatedDataWidth See HP Smart Array Profile NegotiatedSpeed...
  • Page 53: Smx_Sadiskdrivefirmware

    Table 4-6 Class: SMX_SAStorageExtent (CIM_StorageExtent) Property name Property implementation SystemName SMX_SAArraySystem.Name CIM_StorageExtent BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive ExtentStatus[0] Indicates extended status for the disk drive Possible values: 2 (None) 11 (Rebuild—Disk drive is currently rebuilding data) NumberOfBlocks Total number of blocks on disk drive Primordial...
  • Page 54: Smx_Saphysicalpackage

    Table 4-7 Class: SMX_SADiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation VersionString Drive firmware as reported from SCSI identify command HPSA_DiskDriveFirmware SMX_SAPhysicalPackage 4-3-7 SMX_SAPhysicalPackage implements the HPSA_PhysicalPackage class and represents the overall physical package for the array system as a whole. There is one instance per HBA or Storage Subsystem.
  • Page 55: Smx_Sadiskphysicalpackage

    Table 4-9 Class: SMX_SAArrayControllerPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, Smart Array in Slot=3 for internal or Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement Name Controller Serial number...
  • Page 56: Smx_Sastorageenclosure

    Table 4-10 Class: SMX_SADiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation Model Drive model string PartNumber N/A—Not Available in this implementation SerialNumber Drive serial number Opaque Key Version N/A—Not Available in this implementation CIM_PhysicalPackage HotSwappable TRUE—Drive is hot swappable FALSE—Drive is not hot swappable RemovalConditions 2 (Not Applicable) HPSA_...
  • Page 57: Smx_Sastorageenclosureprocessor

    Table 4-11 Class: SMX_SAStorageEnclosure (HP_StorageEnclosure) Property name Property implementation Opaque key Version N/A—Not Available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) CIM_PhysicalFrame CIM_Chassis HP_StorageEnclosure Location See HP Storage Enclosure Profile HPSA_StorageEnclosure SMX_SAStorageEnclosureProcessor 4-3-11 SMX_SAStorageEnclosureProcessor HPSA_StorageEnclosureProcessor class and represents the management processor within a Storage Enclosure.
  • Page 58: Smx_Saportcontroller

    Table 4-12 Class SMX_SAStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SAStorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE—Indicates Storage Device Enclosure OtherIdentifyingInfo[0] Port Number:BoxNumber enclosure is attached to 1E:1...
  • Page 59: Smx_Sadaport

    Table 4-13 Class: SMX_SAPortController (CIM_PortController) Property name Property implementation CIM_LogicalDevice CreationClassName SMX_SAPortController DeviceID Controller serial number SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_Controller CIM_PortController ControllerType 1 (Other) OtherControllerType SCSI – Parallel SCSI HBA SAS/SATA – SAS/SATA HBA HPSA_PortController SMX_SADAPort 4-3-13 SMX_SADAPort implements the HPSA_DAPort class and represents the front-end port for an HBA in the host system.
  • Page 60: Smx_Safirmware

    Table 4-14 Class: SMX_SADAPort (CIM_DAport) Property name Property implementation CreationClassName SMX_SADAPort DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName SMX_SAArraySystem.Name CIM_LogicalPort UsageRestriction 2(Front-End Only) CIM_DAPort HPSA_DAPort SMX_SAFirmware 4-3-14 SMX_SAFirmware implements the HPSA_Firmware class and represents the firmware installed on a Smart Array controller. Table 4-15 Class: SMX_ SAFirmware (CIM_SoftwareIdentity) Property name...
  • Page 61: Smx_Saenclosurefirmware

    SMX_SAEnclosureFirmware 4-3-15 SMX_SAEnclosureFirmware implements the HPSA_EnclosureFirmware class and represents the firmware installed on a Smart Array Enclosure. Table 4-16 Class: SMX_SAEnclosureFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_ManagedElement ElementName TargetType value CIM_ManagedSystemElement Name Storage Enclosure Processor Firmware CIM_LogicalElement Caption Storage Enclosure Processor Firmware Description Storage Enclosure Processor Firmware CIM_SoftwareIdentity...
  • Page 62: Smx_Sastoragepool

    Table 4-17 Class: SMX_SAPrimordialPool (CIM_StoragePool) Property name Property implementation CIM_StoragePool InstanceID Opaque key PoolID Controller serial number Primordial Always set to TRUE RemainingManagedSpace Remaining raw space on controller. This is calculated by summing the remaining space on all drives attached to the controller.
  • Page 63: Smx_Samediaaccessstatdata

    SMX_SAMediaAccessStatData 4-3-18 SMX_SAMediaAccessStatData implements the HPSA_MediaAccessStatData and represents the Monitoring and Performance data counters on HP Disk Drives. Table 4-19 SMX_SAMediaAccessStatData (CIM_MediaAccessStatData) Property name Property implementation CIM_ManagedElement CIM_StatisticalData InstanceID Opaque key SampleInterval CIM_MediaAccessStatData HPSA_MediaAccessStatData AbortedCommands See HP Smart Array Profile BadTargetErrors See HP Smart Array Profile DRQTimeOuts...
  • Page 64: Smx_Sastoragesetting

    SMX_SAStorageSetting 4-3-19 SMX_SAStorageSetting implements the HPSA_StorageSetting class and represents the current raid configuration for a Storage Volume. There is one instance per Storage Volume. Table 4-20 Class: SMX_SAStorageSetting (CIM_StorageSetting) Property name Property implementation CIM_ManagedElement ElementName RAID <n>, where <n> is the raid description •...
  • Page 65: Smx_Sadrivecage

    SMX_SADriveCage 4-3-20 SMX_SADriveCage implements the HPSA_DriveCage class and represents the drive cage assembly and backplane within a storage enclosure. Multiple instances might occur within a duplexed enclosure. Table 4-21 Class: SMX_SADriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port <n>, where <n> is the name of the port this drive cage is connected For example, Port J3 CIM_ManagedSystemElement...
  • Page 66: Smx_Sascsiprotocolcontroller

    Table 4-22 Class: SMX_SASCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation ElementName Controller name and location (for example, Smart Array in Slot=3, or Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller ) CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault...
  • Page 67: Smx_Saredundancyset

    Table 4-23 Class: SMX_SASCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation CIM_ManagedSystemElement OperationalStatus[0] Operational status of the controller 0 (Unknown) 2 (OK) 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASCSIProtocolController DeviceID Opaque key SystemCreationClassName SMX_SAArraySystem SystemName...
  • Page 68: Smx_Sastorageredundancyset

    Table 4-24 Class: SMX_SARedundancySet (CIM_RedundancySet) Property name Property implementation RedundancyStatus 2 (Fully Redundant) 4 (Redundancy Lost) TypeOfSet[0] 4 (Sparing) HPSA_RedundancySet SMX_SAStorageRedundancySet 4-3-24 SMX_SAStorageRedundancySet implements the HPSA_StorageRedundancySet class and represents disk sparing aspect of a RAID configuration. There is an instance for every raid set that has spare drives configured.
  • Page 69: Smx_Sadrivecagelocation

    Table 4-26 Class: SMX_StorageSpecificCollection (HP_GroupHostedCollection) Property name Property implementation Caption Storage Array Consolidated Status Description Storage Array Consolidated Status ElementName Storage Array Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque key HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Consolidated status for all array controllers. See section 9.10 Consolidated status example of HP Smart Array profile for details on how this value is calculated.
  • Page 70: Smx_Saarraysystemlocation

    Table 4-27 Class: SMX_SADriveCageLocation (HP_Location) Property name Property implementation HPSA_DriveCageLocation SMX_SAArraySystemLocation 4-3-27 SMX_SAArraySystemLocation implements the HPSA_ArraySystemLocation class and represents a location string for the array system. Table 4-28 Class: SMX_SAArraySystemLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location Examples: •...
  • Page 71: Smx_Sadiskdrivelocation

    Table 4-28 Class: SMX_SAArraySystemLocation (HP_Location) Property name Property implementation LocationInformation[0] For internal HBAs: PCI Slot number Examples: • 3—PCI Slot 3 • 0—Embedded on Motherboard Not Required for External Storage systems LocationInfoDesc[0] 3 (PCI Slot)—For internal HBAs Not required for External Storage Systems HPSA_ArraySystemLocation SMX_SADiskDriveLocation 4-3-28...
  • Page 72 Table 4-30 Class: SMX_SArrayControllerLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location Examples: • Smart Array in Slot=3, for internal • Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller Description Controller name and location Examples:...
  • Page 73: Smx_Sastoragecapabilities

    SMX_SAStorageCapabilities 4-3-30 SMX_SAStorageCapabilities implements the HPSA_StorageCapabilities class and represents the possible capabilities of a Storage Pool. Table 4-31 Class: SMX_SAStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation CIM_ManagedElement ElementName For Primodial Pools: Controller name and location Examples: • Smart Array in Slot=3, for internal •...
  • Page 74: Smx_Saproduct

    Table 4-31 Class: SMX_SAStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation PackageRedundancyMax 0 (When number of drives <= 1) 1 (When number of drives = 2 or 3) 2 (When number of drives > 3) PackageRedundancyMin HPSA_StorageCapabilities SMX_SAProduct 4-3-31 SMX_SAProduct implements the HPSA_Product class and represents the top level marketing information for the Array System.
  • Page 75: Smx_Satsasport

    Table 4-33 Class: SMX_SAStorageEnclosureLocation (HP_Location) Property name Property implementation Caption Enclosure location Port <m> Box <n>, where <m> is the port and <n> is the box number Description Enclosure location Port <m> Box <n>, where <m> is the port and <n> is the box number Name PhysicalPosition...
  • Page 76: Smx_Satsasscsiprotocolendpoint

    Table 4-34 Class: Class: SMX_SATSASPort (HPSA_TSASPort) Property name Property implementation PortType 94 (SAS) HPSA_SAISASPort SMX_SATSASSCSIProtocolEndpoint 4-3-34 SMX_SATSASSCSIProtocolEndpointPort implements the HPSA_TSASSCSIProtocolEndpoint class and represents an access point to storage resources. Table 4-35 Class: SMX_SATSASSCSIProtocolEndpoitPort (HPSA_TSASSCSIProtocolEndpoint) Property name Property implementation ElementName Protocol Endpoint for xxx, where xxx is the value populated in the caption property of the instance of HPSA_TSASPort associated to this instance through the association HPSA_TSASPortTSASSCSIPE...
  • Page 77: Smx_Saisasscsiprotocolendpoint

    Table 4-36 Class: Class: SMX_SAISASPort (HPSA_ISASPort) Property name Property implementation OperationalStatus[0] Port status 0 (Unknown) 2 (OK) 6 (Error) EnabledDefault 2 (Enabled EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CreationClassName “SMX_SAISASPort” DeviceID HPSA_PortController.DeviceID>:<port #>, where <HPSA_PortController.DeviceID> is the DeviceID property of the instance of HPSA_PortController associated to this instance through the association HPSA_PortControllerISASPort and <port #>...
  • Page 78: Smx_Saarraysystemisasport (Association)

    Table 4-37 Class: SMX_SAISASSCSIProtocolEndpoitPort (HPSA_ISASSCSIProtocolEndpoint) Property name Property implementation CreationClassName “SMX_SAISASSCSIProtocolEndpoint” SystemCreationClassName “SMX_SAArraySystem” SystemName SMX_SAArraySystem.Name ProtocolIFType 1 (Other) OtherTypeDescription “SCSI” Role 2 (Initiator) HPSA_SAISASSCSIProtocolEndpoint SMX_SAISASPortISASSCSIProtocolEndPoint 4-3-37 (Association) Table 4-38 Class: SMX_SAISASPortISASSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent SMX_SAISASPort Dependent SMX_SASASISASSCSIProtocolEndpoint SMX_SAArraySystemISASSCSIProtocolEndpoint 4-3-38 (Association)
  • Page 79: Smx_Saarraysystemtsasport (Association)

    SMX_SATSASPortTSASSCSIProtocolEndPoint 4-3-40 (Association) Table 4-41 Class: SMX_SATSASPortTSASSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent SMX_SATSASPort Dependent SMX_SASASTSASSCSIProtocolEndpoint SMX_SAArraySystemTSASSCSIProtocolEndpoint 4-3-41 (Association) Table 4-42 Class: SMX_SAArraySystemTSASSCSIProtocolEndpoint (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SATSASSCSIProtocolEndpoint SMX_SAArraySystemTSASPort (Association) 4-3-42 Table 4-43 Class: SMX_SAArraySystemTSASPort (CIM_SystemDevice) Property name Property implementation GroupComponent...
  • Page 80: Smx_Saarraysystemredundancyset (Association)

    Table 4-45 Class: SMX_SASCSIInitiatorTargetLogicalUnitPath (CIM_InitiatorTargetLogicalUnitPath) LogicalUnit SMX_SAStorageExtent State 0 (Unknown) if the path status cannot be ascertained 2 (active) if the path is active and health 5 (path error) if the path has an error condition 3 (passive) path is health but is not active or is the standby path SMX_SAArraySystemRedundancySet (Association) 4-3-45...
  • Page 81: Smx_Saarraysystemportcontroller (Association)

    SMX_SAStoragePoolStorageCapabilities 4-3-48 (Association) Table 4-49 Class: SMX_SAStoragePoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SAStorageCapabilities ManagedElement SMX_ SAStoragePool SMX_SAArraySystemStorageEnclosureProcessor 4-3-49 (Association) Table 4-50 Class: SMX_SAPrimordialPoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAStorageEnclosureProcessor SMX_SAArraySystemSCSIProtocolController 4-3-50 (Association) Table 4-51 Class: SMX_SAArraySystemSCSIProtocolController (CIM_SystemDevice) Property name Property implementation GroupComponent...
  • Page 82: Smx_Saarraysystemstoragevolume (Association)

    Table 4-53 Class: SMX_SAArraySystemDiskDrive (CIM_SystemDevice) PartComponent SMX_ SADiskDrive SMX_SAArraySystemStorageVolume (Association) 4-3-53 Table 4-54 Class: SMX_SAArraySystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_ SAStorageVolume SMX_SAArraySystemStorageExtent (Association) 4-3-54 Table 4-55 Class: SMX_SAArraySystemStorageExtent (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_ SAStorageExtent SMX_SAArraySystemDAPort (Association) 4-3-55...
  • Page 83: Smx_Sacomputersystemarraysystem (Association)

    Table 4-58 Class: SMX_ SAArraySystemStoragePool (CIM_HostedStoragePool) PartComponent SMX_SAStoragePool SMX_SAComputerSystemArraySystem (Association) 4-3-58 Table 4-59 Class: SMX_ SAComputerSystemArraySystem (CIM_ComponentCS) Property name Property implementation GroupComponent HP_ComputerSystem PartComponent SMX_SAArraySystem SMX_SAArraySystemArrayController (Association) 4-3-59 Table 4-60 Class: SMX_ SAArraySystemArrayController (CIM_ComponentCS) Property name Property implementation GroupComponent SMX_SAArraySystem PartComponent SMX_SAArrayController SMX_SAStorageEnclosureStorageEnclosureProcessor...
  • Page 84: Smx_Sastoragepoolstorageextent (Association)

    Table 4-63 Class: SMX_SAStorageEnclosureDriveCage (CIM_Container) GroupComponent SMX_SAStorageEnclosure PartComponent SMX_SADriveCage SMX_SAPhysicalPackageArrayControllerPhysicalPack 4-3-63 age (Association) Table 4-64 Class: SMX_SAPhysicalPackageArrayControllerPhysicalPackage (CIM_Container) Property name Property implementation GroupComponent SMX_SAPhysicalPackage PartComponent SMX_SAArrayControllerPhysicalPackage SMX_SAPhysicalPackageStorageEnclosure 4-3-64 (Association) Table 4-65 Class: SMX_SAPhysicalPackageStorageEnclosure (CIM_Container) Property name Property implementation GroupComponent SMX_SAPhysicalPackage PartComponent SMX_SAStorageEnclosure SMX_SADriveCageDiskPhysicalPackage...
  • Page 85: Smx_Saprimordialpoolstorageextent (Association)

    SMX_SAPrimordialPoolStorageExtent (Association) 4-3-67 Table 4-68 Class: SMX_SAPrimordialPoolStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent SMX_SAPrimordialPool PartComponent SMX_SAStorageExtent SMX_SAStorageSpecificCollectionArraySystem 4-3-68 (Association) Table 4-69 Class: SMX_SAStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SAStorageSpecificCollection Member SMX_SAArraySystem SMX_SAArrayControllerRedundancySet (Association) 4-3-69 Table 4-70 Class: SMX_SAArrayControllerRedundancySet (CIM_MemberOfCollection) Property name Property implementation Collection...
  • Page 86: Smx_Safirmwarearraysystem (Association)

    SMX_SASCSIProtocolControllerStorageVolume 4-3-72 (Association) Table 4-73 Class: SMX_SASCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent SMX_SASCSIProtocolController Dependent SMX_SAStorageVolume DeviceAccess 2 (Read Write) DeviceNumber Device LUN number SMX_SAFirmwareArraySystem (Association) 4-3-73 Table 4-74 Class: SMX_SAFirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SAFirmware Dependent SMX_SAArraySystem ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current)
  • Page 87: Smx_Sadiskdrivestorageextent (Association)

    Table 4-76 Class: SMX_SADiskDriveDiskDriveFirmware (CIM_ElementSoftwareIdentity) Antecedent SMX_SADiskDriveFirmware Dependent SMX_SADiskDrive ElementSoftwareStatus ElementSoftwareStatus[0]: 2 (Current) ElementSoftwareStatus[1]: 6 (Installed) SMX_SADiskDriveStorageExtent (Association) 4-3-76 Table 4-77 Class: SMX_SADiskDriveStorageExtent (CIM_MediaPresent) Property name Property implementation Antecedent SMX_SADiskDrive Dependent SMX_SAStorageExtent SMX_SADiskPhysicalPackageDiskDrive (Association) 4-3-77 Table 4-78 Class: SMX_SADiskPhysicalPackageDiskDrive (CIM_Realizes) Property name Property implementation Antecedent...
  • Page 88: Smx_Saspareextentstorageextent (Association)

    SMX_SASpareExtentStorageExtent (Association) 4-3-80 Table 4-81 Class: SMX_SASpareExtentStorageExtent (CIM_Spared) Property name Property implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageExtent SMX_SASpareExtentStorageRedundancySet 4-3-81 (Association) Table 4-82 Class: SASpareExtentStorageRedundancySet (CIM_IsSpare) Property name Property implementation Antecedent SMX_SAStorageExtent Dependent SMX_SAStorageRedundancySet SMX_SAStorageExtentStorageVolume (Association) 4-3-82 Table 4-83 Class: SMX_SAStorageExtentStorageVolume (CIM_BasedOn) Property name Property implementation Antecedent...
  • Page 89: Smx_Saphysicalpackagearraysystem (Association)

    SMX_SAPhysicalPackageArraySystem (Association) 4-3-85 Table 4-86 Class: SMX_SAPhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Antecedent SMX_SAPhysicalPackage Dependent SMX_SAArraySystem SMX_SAArrayControllerPhysicalPackageArrayControl 4-3-86 ler (Association) Table 4-87 Class: SMX_SAArrayControllerPhysicalPackageArrayController (CIM_ComputerSystemPackage) Property name Property implementation Antecedent SMX_SAArrayControllerPhysicalPackage Dependent SMX_SAArrayController SMX_SADiskDriveMediaAccessStatData 4-3-87 (Association) Table 4-88 Class: SMX_SADiskDriveMediaAccessStatData (CIM_ElementStatisticalData) Property name Property implementation ManagedElement...
  • Page 90: Smx_Sadrivecagedrivecagelocation (Association)

    SMX_SAPhysicalPackageArraySystemLocation 4-3-89 (Association) Table 4-90 Class: SMX_SAPhysicalPackageArraySystemLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SAPhysicalPackage PhysicalLocation SMX_SAArraySystemLocation SMX_SADriveCageDriveCageLocation (Association) 4-3-90 Table 4-91 Class: SMX_SADriveCageDriveCageLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SADriveCage PhysicalLocation SMX_SADriveCageLocation SMX_SADiskPhysicalPackageDiskDriveLocation 4-3-91 (Association) Table 4-92 Class: SMX_SADiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element...
  • Page 91: Hp_Deviceindication: Physical Drive Status Changed To Ok

    Table 4-94 Class: SMX_SAStorageEnclosureEnclosureLocation (CIM_PhysicalElementLocation) Element SMX_SAStorageEnclosure PhysicalLocation SMX_SAStorageEnclosureLocation Supported indications HP_DeviceIndication: Physical Drive Status Changed 4-4-1 to OK Table 4-95 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication...
  • Page 92 Table 4-95 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication...
  • Page 93: Hp_Deviceindication: Physical Drive Status Changed To Error

    Table 4-95 HP_DeviceIndication: Physical Drive Status Changed to OK Property name Property implementation VariableNames Failure Description DriveInterface LastFailureDescription VariableTypes[] String (1) uint16 (4) VariableValues[] FailureDescription short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription – last failure reason string from the drive.
  • Page 94 HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-96 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation HP_AlertIndication Summary Physical Drive status is now Error EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication...
  • Page 95: Hp_Deviceindication: Physical Drive Status Changed To Rebuilding

    HP_DeviceIndication: Physical Drive Status 4-4-2 Changed to ERROR Table 4-96 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Physical Disk F/W version string HWLogicalLocation Physical Disk Location string For exmaple, Port:1E Box: 1 Bay 5...
  • Page 96 HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Physical drive status has changed to Rebuilding. Data is now being rebuilt onto this drive from the array system.
  • Page 97 HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication ImpactedDomain 3 (Enclosure) for c-Class blade systems...
  • Page 98: Hp_Deviceindication: Physical Drive Status Changed To Predictive Failure

    HP_DeviceIndication: Physical Drive Status 4-4-3 Changed to REBUILDING Table 4-97 HP_DeviceIndication: Physical Drive Status Changed to REBUILDING Property name Property implementation DeviceModel Physical Disk Model string DeviceControllerLogicalLocation Controller Location For exmaple, SmartArray 642 in Slot 2, Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HP_DeviceIndication: Physical Drive Status...
  • Page 99 HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-98 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation ProbableCause 86 (Disk Failure) ProbableCauseDescription Physical Drive Status Changed to Predictive Failure NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
  • Page 100: Hpsa_Storagevolumeindication: Logical Drive Status Changed To Ok

    HP_DeviceIndication: Physical Drive Status 4-4-4 Changed to PREDICTIVE FAILURE Table 4-98 HP_DeviceIndication: Physical Drive Status Changed to PREDICTIVE FAILURE Property name Property implementation HWLogicalLocation Physical Disk Location string For example, Port:1E Box: 1 Bay 5 HWPhysicalLocation Physical Location of the Failed Drive (Bay Number) HWSerialNumber Physical Disk Serial Number VariableNames[]...
  • Page 101 HPSA_StorageVolumeIndication: Logical Drive 4-4-5 Status Changed to OK Table 4-99 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name Property implementation AlertingMangedElement WBEM Path of SMX_SAStorageVolume AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array...
  • Page 102 HPSA_StorageVolumeIndication: Logical Drive 4-4-5 Status Changed to OK Table 4-99 HPSA_StorageVolumeIndication : Logical Drive Status Changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems NOTE: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated.
  • Page 103: Smx_Sastoragevolumeindication: Logical Drive Status Changed To Error

    SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-100 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (Major) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed to Error.
  • Page 104 SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-100 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 105: Smx_Sastoragevolumeindication: Logical Drive Status Changed To Degraded

    SMX_SAStorageVolumeIndication: Logical Drive 4-4-6 Status Changed to ERROR Table 4-100 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name Property implementation DeviceOperationalStatus Current OperationalStatus values for Storage Volume DeviceOperationalStatus[0]: SMX_SAStorageVolume.OperationalStatus[0] DeviceOperationalStatus[1]: SMX_SAStorageVolume.OperationalStatus[1] (This index is only populated if there is addional Vendor unique status available) DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume...
  • Page 106 SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-101 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array RecommendedActions Check status of physical drives.
  • Page 107 SMX_SAStorageVolumeIndication: Logical Drive 4-4-7 Status Changed to Degraded Table 4-101 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to Degraded Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect...
  • Page 108: Hp_Deviceindication: Controller Status Changed To Ok

    HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-102 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller status has changed from non- OK to OK.
  • Page 109 HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-102 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
  • Page 110: Hp_Deviceindication: Controller Status Changed To Error

    HP_DeviceIndication: Controller Status Changed to 4-4-8 Table 4-102 HP_DeviceIndication: Controller Status Changed to OK Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-103...
  • Page 111 HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-103 HP_DeviceIndication: Controller Status Changed to ERROR Property name Property implementation ProbableCause 24 (I/O device error)) ProbableCauseDescription Array Controller Status Changed to Error NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
  • Page 112: Hp_Deviceindication: Controller Redundancy State Has Been Set To Active

    HP_DeviceIndication: Controller Status Changed to 4-4-9 ERROR Table 4-103 HP_DeviceIndication: Controller Status Changed to ERROR Property name Property implementation HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HWManufacturer Array Controller Manufacturer string...
  • Page 113 HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-104 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP Smart Array...
  • Page 114 HP_DeviceIndication: Controller Redundancy state 4-4-10 has been set to Active Table 4-104 HP_DeviceIndication: Controller Redundancy state has been set to Active Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems Note: When ImpactedDomain is 3 (Enclosure) the properties indicated with (*) are populated.
  • Page 115: Hp_Deviceindication: Controller Redundancy Has Been Lost

    HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller has detected that redundancy has been lost due to failure or loss of communication with partner controller.
  • Page 116 HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID...
  • Page 117: Hp_Deviceindication: Controller Redundancy Has Been Restored

    HP_DeviceIndication: Controller Redundancy has 4-4-11 been lost Table 4-105 HP_DeviceIndication: Controller Redundancy has been lost Property name Property implementation VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-106...
  • Page 118 HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-106 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation EventCategory 6 (Primary Storage) ProbableCause 1 (other) ProbableCauseDescription Array Controller Redundancy has been Restored NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType SMX_OperatingSystem.OSType...
  • Page 119: Hp_Deviceindication: Controller Battery Status Change - Ok

    HP_DeviceIndication: Controller Redundancy has 4-4-12 been restored Table 4-106 HP_DeviceIndication: Controller Redundancy has been restored Property name Property implementation HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5 Smart Array P400 Embedded Controller=7” for embedded controller where 7 is the internal identifier for the embedded controller HWManufacturer...
  • Page 120 HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-107 HP_DeviceIndication: Controller Battery Status Change - OK Property name Property implementation AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SmartArray...
  • Page 121 HP_DeviceIndication: Controller Battery Status 4-4-13 Change - OK Table 4-107 HP_DeviceIndication: Controller Battery Status Change - OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 122: Hp_Deviceindication: Controller Battery Status Changed To Not Fully Charged

    HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-108 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Smart Array controller Battery status has changed to Not Fully Charged.
  • Page 123 HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-108 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
  • Page 124: Hp_Deviceindication: Controller Battery Status Changed To Failed

    HP_DeviceIndication: Controller Battery status 4-4-14 changed to not fully charged Table 4-108 HP_DeviceIndication: Controller Battery status changed to not fully charged Property name Property implementation VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel...
  • Page 125 HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed Table 4-109 HP_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation HP_AlertIndication Summary Controller Battery Status set to Failed. EventCategory 6 (Primary Storage) ProbableCause 92 (battery failure) ProbableCauseDescription Controller Battery Status Changed to Failed NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication...
  • Page 126: Hp_Deviceindication: Controller Cache Status - Ok

    HP_DeviceIndication: Controller Battery status 4-4-15 changed to Failed Table 4-109 HP_DeviceIndication: Controller Battery status changed to Failed Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Array Controller firmware version string HWLogicalLocation Array Controller Location string For example, Smart Array P600 in Slot 5...
  • Page 127 HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-110 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation Description Smart Array Controller Cache Status has changed to a status of OK. AlertingMangedElement WBEM path to the SMX_SAArrayController class. AlertingElementFormat 2 (CIMObjectPath) AlertType...
  • Page 128 HP_DeviceIndication: Controller Cache Status - OK 4-4-16 Table 4-110 HP_DeviceIndication: Controller Cache status changed to OK Property name Property implementation ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 129: Hp_Deviceindication: Controller Cache Status—Temporarily Disabled

    HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description Smart Array Controller Cache Status is set to a status of Temporarily Disabled.
  • Page 130 HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 131: Hp_Deviceindication: Controller Cache Status—Permanently Disabled

    HP_DeviceIndication: Controller Cache status— 4-4-17 Temporarily Disabled Table 4-111 HP_DeviceIndication: Controller Cache status—Temporarily Disabled Property name Property implementation VariableTypes[] String (1) uint32 (5) VariableValues[] FailureDescription short description of the failure CacheSizeTotal HPSA_ArrayController.CacheSizeTotal CacheSerialNumber HPSA_ArrayController.CacheSerialNumber HP_DeviceIndication DeviceModel Array Controller Model string HP_DeviceIndication: Controller Cache status—...
  • Page 132 HP_DeviceIndication: Controller Cache status— 4-4-18 Permanently Disabled Table 4-112 HP_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Array Controller Cache Status is Permanently Disabled. EventCategory 6 (Primary Storage) ProbableCause 35 (Performance Degraded) ProbableCauseDescription...
  • Page 133: Hp_Deviceindication: Enclosure Power Supply Status Changed To Non Redundant

    HP_DeviceIndication: Controller Cache status— 4-4-18 Permanently Disabled Table 4-112 HP_DeviceIndication: Controller Cache status—Permanently Disabled Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion...
  • Page 134 HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-113 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description Storage Enclosure Power Subsystem status has changed to a Non Redundant Status AlertingMangedElement WBEM path of the SMX_SAStorageEnclosureProcessor AlertingElementFormat...
  • Page 135: Hp_Deviceindication: Enclosure Power Supply Status Changed To Ok (Redundant)

    HP_DeviceIndication: Enclosure Power Supply 4-4-19 status changed to Non Redundant Table 4-113 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
  • Page 136 HP_DeviceIndication: Enclosure Power Supply 4-4-20 status changed to OK (Redundant) Table 4-114 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to...
  • Page 137: Hp_Deviceindication: Enclosure Power Supply Status Changed To Redundant Degraded

    HP_DeviceIndication: Enclosure Power Supply 4-4-20 status changed to OK (Redundant) Table 4-114 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
  • Page 138 HP_DeviceIndication: Enclosure Power Supply 4-4-21 status changed to Redundant Degraded Table 4-115 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Power Subsystem has changed to Degraded Redundancy.
  • Page 139: Hp_Deviceindication: Enclosure Temperature Sensor Status Changed To Ok

    HP_DeviceIndication: Enclosure Power Supply 4-4-21 status changed to Redundant Degraded Table 4-115 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 140 HP_DeviceIndication: Enclosure Temperature 4-4-22 sensor status changed to OK Table 4-116 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed from Non-OK to a status of OK.
  • Page 141: Hp_Deviceindication: Enclosure Temperature Sensor Status Changed To Warning

    HP_DeviceIndication: Enclosure Temperature 4-4-22 sensor status changed to OK Table 4-116 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 142 HP_DeviceIndication: Enclosure Temperature 4-4-23 sensor status changed to Warning Table 4-117 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status changed to Warning Condition.
  • Page 143 HP_DeviceIndication: Enclosure Temperature 4-4-23 sensor status changed to Warning Table 4-117 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
  • Page 144: Hp_Deviceindication: Enclosure Temperature Sensor Status Changed To Critical

    HP_DeviceIndication: Enclosure Temperature 4-4-24 sensor status changed to Critical Table 4-118 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Temperature sensor status has changed to Critical.
  • Page 145 HP_DeviceIndication: Enclosure Temperature 4-4-24 sensor status changed to Critical Table 4-118 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
  • Page 146: Hp_Deviceindication: Enclosure Fan Status Changed To Ok

    HP_DeviceIndication: Enclosure Fan status 4-4-25 changed to OK Table 4-119 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 2 (Info) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed from a status of Non-OK to a status of OK.
  • Page 147 HP_DeviceIndication: Enclosure Fan status 4-4-25 changed to OK Table 4-119 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 148: Hp_Deviceindication: Enclosure Fan Status Changed To Degraded

    HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-120 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at indication PerceivedSeverity 3 (Warning) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to a status of Degraded.
  • Page 149 HP_DeviceIndication: Enclosure Fan status 4-4-26 changed to Degraded Table 4-120 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
  • Page 150: Hp_Deviceindication: Enclosure Fan Status Changed To Failure

    HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-121 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan status changed to a status of Failure.
  • Page 151 HP_DeviceIndication: Enclosure Fan status 4-4-27 changed to Failure Table 4-121 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation ProviderVersion 2.2.0.0 SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the...
  • Page 152: Hpvc_Sacontroller

    Smart Array View Class Overview The HP Smart Array View Class data sheet describes host based Smart Array HBA’s and the attached devices. The current View Class implementation does not support externally attached Smart Array based MSA devices. For example, MSA500, or MSA20. Class Implementations HPVC_SAController 5-2-1...
  • Page 153: Hpvc_Sacontrollerfirmware

    Table 5-1 Class: HPVC_SAController Property name Property implementation VMware_Controller HPVC_SAController HPVC_SAControllerFirmware 5-2-2 HPVC_SAControllerFirmware represents Smart Array controller firmware. There is one instance per HBA. Table 5-2 Class: HPVC_SAControllerFirmware Property name Property implementation CIM_ManagedElement ElementName Smart Array Controller X Note: VMware Virtual Infrastructure client requires controller name string X matches “vmwControllerX”...
  • Page 154: Hpvc_Sastorageextent

    Table 5-3 Class: HPVC_SABattery Property name Property implementation CIM_LogicalDevice CreationClassName HPVC_SABattery DeviceID Battery on HPSA X SystemCreationClassName SMX_ComputerSystem SystemName Server host name CIM_Battery BatteryStatus 1(Other) 2(Unknown) 3(Fully Charged) 4(Low) 5(Critical) 6(Charging) 7(Charging and High) 8(Charging and Low) 9(Charging and Critical) 10(Undefined) 11(Partially Charged) 12(Learning)
  • Page 155: Hpvc_Sastoragevolume

    Table 5-4 Class: HPVC_SAStorageExtent Property name Property implementation CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageExtent DeviceID HPVC_SAStorageExtent-<model>-<serial number> For example, HPVC_SAStorageExtent- HPDG072BB975-3NP2TCCF000098402P95 SystemCreationClassName SMX_ComputerSystem SystemName Server host name CIM_StorageExtent BlockSize Block size in bytes NumberOfBlocks Total number of blocks on disk drive Primordial Set to True VMware_StorageExtent HPVC_SAStorageExtent...
  • Page 156 Table 5-5 Class: HPVC_SAStorageVolume Property name Property implementation HealthState 0 (Unknown) 5 (OK) 10 (Degraded/Warning) 15 (Minor Failure) 20 (Major Failure) 25 (Critical Failure) 30 (Non-recoverable Error) CIM_LogicalElement CIM_EnabledLogicalElement CIM_LogicalDevice CreationClassName HPVC_SAStorageVolume DeviceID HPVC_SAStorageVolume-<unique volume ID> For example, HPVC_SAStorageVolume- 600508b10010463956564636454e0007 SystemCreationClassName SMX_ComputerSystem SystemName...
  • Page 157: Smx_Sasarraysystem

    SMX_SAS HBA Provider Overview The following chapters define the supported properties for the SAS HBA provider. For details of each property, see the HP SAS HBA profile (P00122) and associated MOF file. SMX_SASArraySystem 6-1-1 SMX_SASArraySystem represents the top level system. There is one instance per HBA. Table 6-1 Class: SMX_SASArraySystem (CIM_ComputerSystem) Property name...
  • Page 158: Smx_Sasarraycontroller

    Table 6-1 Class: SMX_SASArraySystem (CIM_ComputerSystem) Property name Property implementation OtherIdentifyingInfo Controller Serial Number SMX_SASArrayController 6-1-2 SMX_SASArrayController represents the controller. There is one per HBA. Table 6-2 Class: SMX_SASArrayController (CIM_ComputerSystem) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Status for Array Controller...
  • Page 159 Table 6-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation CIM_ManagedElement ElementName Logical drive number with raid description For example, Logical Volume 1 (RAID 1) CIM_ManagedSystemElement Name Concatenation of Vendor + Model + SerialNumber+Logical Drive number For example, HP+HP 8 INT Port SAS/SATA HBA+C007760405+LD1 CIM_LogicalElement CIM_EnabledLogicalElement...
  • Page 160: Smx_Sasdiskdrive

    Table 6-3 Class: SMX_SASStorageVolume (CIM_StorageVolume) Property name Property implementation NameFormat 7 (SNVM) SMX_SASStoragevolume Deleteable See HP SAS HBA Profile FaultTolerance See HP SAS HBA Profile OperationalStatus[0] Volume status • 0 (Unknown) • 2 (OK) • 3 (Degraded) - RAID redundancy lost or rebuilding data •...
  • Page 161: Smx_Sasstorageextent

    Table 6-4 Class: SMX_SASDiskDrive (CIM_DiskDrive) Property name Property implementation SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_MediaAccessDevice CIM_DiskDrive SMX_SASDiskDrive DriveConfiguration See HP SAS HBA Profile DriveHasMNPData See HP SAS HBA Profile DriveInterface See HP SAS HBA Profile DrivePlacement See HP SAS HBA Profile DriveRotationalSpeed See HP SAS HBA Profile Description...
  • Page 162: Smx_Sasdiskdrivefirmware

    Table 6-5 Class: SMX_SASStorageExtent (CIM_StorageExtent) Property name Property implementation EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASStorageExtent DeviceID Opaque ID SystemCreationClassName SMX_SASArraySystem SystemName SMX_SASArraySystem.Name CIM_StorageExtent BlockSize Block size in bytes ConsumableBlocks Total number of blocks on disk drive ExtentStatus[0] Indicates extended status for the disk drive •...
  • Page 163: Smx_Sasphysicalpackage

    Table 6-6 Class: SMX_SASDiskDriveFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_SoftwareIdentity ClassificationDescriptions[0] Disk Drive Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Disk drive vendor string IdentityInfoType [0]CIM:SoftwareFamily [1]HPQ:SoftwareCategory IdentityInfoValue [0]HPQ:<TargetType value> [1]Storage Device VersionString Drive firmware as reported from SCSI identify command IsEntity False(always set to False)
  • Page 164: Smx_Sasdiskphysicalpackage

    Table 6-7 Class: SMX_SASPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_SASPhysicalPackage SMX_SASDiskPhysicalPackage 6-1-8 SMX_SASDiskPhysicalPackage represents the physical aspects of the disk drive. There is one instance per disk drive. Table 6-8 Class: SMX_SASDiskPhysicalPackage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName...
  • Page 165: Smx_Sasportcontroller

    SMX_SASPortController 6-1-9 SMX_SASPortController represent the HBA in the host system. There is one instance per HBA. Table 6-9 Class: SMX_SASPortController (CIM_PortController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location, for example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement CIM_LogicalElement CIM_EnabledLogicalElement...
  • Page 166: Smx_Sasfirmware

    Table 6-10 Class: SMX_SASDAPort (CIM_DAPort) Property name Property implementation OperationalStatus[0] Port status • 0 (Unknown) • 2 (OK) • 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_SASDAPort DeviceID Opaque key SystemCreationClassName SMX_SASArraySystem SystemName...
  • Page 167: Smx_Sasprimordialpool

    Table 6-11 Class: SMX_SASFirmware (CIM_SoftwareIdentity) Property name Property implementation CIM_SoftwareIdentity ClassificationDescriptions[0] HBA Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Controller Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1] HPQ:SoftwareCategory IdentityInfoValue [0]HPQ:<TargetType value> Set to controller model [1]:Storage Controller VersionString Controller firmware version string IsEntity False (always set to False) SMX_SASFirmware...
  • Page 168: Smx_Sasprimordialpoolnoraid

    SMX_SASPrimordialPoolNoRaid 6-1-13 SMX_SASPrimordialPoolNoRaid represents the total raw storage managed by the array controller that is not assigned to raid volumes. Table 6-13 Class: SMX_SASPrimordialPoolNoRaid (CIM_StoragePool) Property name Property implementation CIM_ManagedElement ElementName Controller name and location: pool identifier For example, HP 8 INT Port SAS/SATA HBA in Slot 3: Primordial Pool (No Raid) CIM_ManagedSystemElement CIM_LogicalElement...
  • Page 169: Smx_Sasstoragesetting

    Table 6-14 Class: SMX_SASStoragePool (CIM_StoragePool) Property name Property implementation Primordial FALSE RemainingManagedSpace TotalManagedSpace Total raw space managed by this pool SMX_SASStoragePool SMX_SASStorageSetting 6-1-15 SMX_SASStorageSetting represents the current raid configuration for a Storage Volume. There is one instance per Storage Volume. Table 6-15 Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name...
  • Page 170: Smx_Sasscsiprotocolendpoint

    Table 6-15 Class: SMX_SASStorageSetting (CIM_StorageSetting) Property name Property implementation PackageRedundancyMin • 0 (RAID 0) • 1 (RAID 1) SMX_SASStorageSetting SMX_SASSCSIProtocolEndpoint 6-1-16 SMX_SASSCSIProtocolEndpoint represents an access point to storage resources. Table 6-16 Class: SMX_SASSCSIProtocolEndpoint (CIM_SCSIProtocolEndpoint) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement...
  • Page 171: Smx_Sasstorageredundancyset

    Table 6-17 Class: SMX_SASSCSIProtocolController (CIM_SCSIProtocolController) Property name Property implementation CIM_ManagedElement ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 CIM_ManagedSystemElement OperationalStatus[0] Operational status of the controller • 0 (Unknown) • 2 (OK) • 6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement...
  • Page 172: Smx_Sasstoragespecificcollection

    Table 6-18 Class: SMX_SASStorageRedundancySet (CIM_StorageRedundancySet) Property name Property implementation CIM_RedundancySet LoadBalanceAlgorithm 2 (No Load Balancing) MaxNumberSupported MinNumberNeeded RedundancyStatus • 2 (Fully Redundant) • 4 (Redundancy Lost) TypeOfSet[0] 5 (Limited Sparing) CIM_StorageRedundancySet SMX_SASStorageRedundancySet SMX_SASStorageSpecificCollection 6-1-19 SMX_SASStorageSpecificCollection represents a collection of SAS HBA controllers that are grouped together to report consolidated status.
  • Page 173: Smx_Sasdiskdrivelocation

    Table 6-20 Class: SMX_SASArraySystemLocation (HP_Location) Property name Property implementation CIM_ManagedElement Caption Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 Description Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3 ElementName Controller name and location For example, HP 8 INT Port SAS/SATA HBA in Slot 3...
  • Page 174: Smx_Sasstoragecapabilities

    Table 6-21 Class: SMX_SASDiskDriveLocation (HP_Location) Property name Property implementation PhysicalPosition Opaque key HP_Location ElementLocationTag Bay Number or SCSI ID of Disk ElementLocationTagDesc 20 (Bay) or 21 (SCSI ID) SMX_SASDiskDriveLocation SMX_SASStorageCapabilities 6-1-22 SMX_SASStorageCapabilities represents the possible capabilities of a Storage Pool. Table 6-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name...
  • Page 175: Smx_Sasproduct

    Table 6-22 Class: SMX_SASStorageCapabilities (CIM_StorageCapabilities) Property name Property implementation NoSinglePointOfFailure • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) • False—When number of drives = 1 or Pool is NonRAID NoSinglePointOfFailureDefault • True—When number of drives > 1 (For example, Pool can be configured for redundancy.) •...
  • Page 176: Smx_Sasenclosurefirmware

    Table 6-24 Class: SMX_SASDriveCage (CIM_PhysicalPackage) Property name Property implementation CIM_ManagedElement ElementName Port <m> Box <n>, where <m> is the name of the port this drive cage is connected and <n> is the Box Number For example, Port IE Box 1 CIM_ManagedSystemElement Name Serial Number of drive cage...
  • Page 177: Smx_Sasstorageenclosure

    Table 6-25 Class: SMX_SASEnclosureFirmware (CIM_SoftwareIdentity) Property name Property Implemenation CIM_LogicalElement Caption Storage Enclosure Firmware Description Storage Enclosure Firmware CIM_SoftwareIdentity ClassificationDescriptions[0] Storage Enclosure Firmware Classifications[0] 10 (Firmware) InstanceID Opaque key Manufacturer Enclosure Vendor string IdentityInfoType [0]CIM:SoftwareFamily [1] HPQ:SoftwareCategory IdentityInfoValue [0]HPQ:<TargetType value> [1] Storage Device VersionString Enclosure firmware string...
  • Page 178: Smx_Sasstorageenclosureprocessor

    Table 6-26 Class: SMX_SASStorageEnclosure (HP_StorageEnclosure) Property name Property implementation PartNumber N/A—Not available in this implementation SerialNumber Enclosure Serial Number N/A is reported if there is no serial number (for example, internal enclosures). Opaque key Version N/A—Not available in this implementation CIM_PhysicalPackage RemovalConditions 2 (Not Applicable)
  • Page 179: Smx_Sasstorageenclosurelocation

    Table 6-27 Class: SMX_SASStorageEnclosureProcessor (CIM_ComputerSystem) Property name Property implementation CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_SASStorageEnclosureProcessor Name Opaque Key NameFormat Other CIM_ComputerSystem Dedicated[0] 2 (Other) IdentifyingDescriptions[0] Other Vendor Specific Name OtherDedicatedDescriptions[0] SDE - indicates Storage Device Enclosure OtherIdentifyingInfo[0] Vendor:SerialNumber enclosure is attached to...
  • Page 180: Smx_Sasdrivecagediskdrive (Association)

    Table 6-28 Class: HPAS_StorageEnclosureLocation (HP_Location) Property name Property implementation ElementLocationTagDesc 19 (Box) SMX_SASDriveCageDiskDrive (Association) 6-1-29 Table 6-29 Class: SMX_SASDriveCageDiskDrive (CIM_Container) Property name Property implementation GroupComponent SMX_SASDriveCage PartComponent SMX_SASDiskPhysicalPackage SMX_SASStorageEnclosureDriveCage (Association) 6-1-30 Table 6-30 Class: SMX_SASStorageEnclosureDriveCage (CIM_Container) Property name Property implementation GroupComponent SMX_SASStorageEnclosure PartComponent...
  • Page 181: Smx_Sasstoragevolumestoragesetting (Association)

    Table 6-32 Class: SMX_SASArraySystemStorageEnclosureProcessor (CIM_SystemComponent) Property name Property implementation PartComponent SMX_SASStorageEnclosureProcessor SMX_SASStorageEnclosureProcessorEnclosureFirmware 6-1-33 (Association) Table 6-33 Class: SMX_SASStorageEnclosureProcessorEnclosureFirmware (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASEnclosureFirmware Dependent SMX_SASStorageEnclosureProcessor ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) • ElementSoftwareStatus[1]: 6 (Installed) SMX_SASStorageEnclosureStorageEnclosureProcessor 6-1-34 (Association) Table 6-34 Class: SMX_SASStorageEnclosureStorageEnclosureProcessor (CIM_systemPackaging) Property name Property implementation...
  • Page 182: Smx_Sasstoragepoolstoragecapabilities (Association)

    SMX_SASPrimordialPoolStorageCapabilities 6-1-36 (Association) Table 6-36 Class: SMX_SASPrimordialPoolStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElement SMX_SASPrimordialPool SMX_SASPrimordialPoolNoRaidStorageCapabilities 6-1-37 (Association) Table 6-37 Class: SMX_SASPrimordialPoolNoRaidStorageCapabilities (CIM_ElementCapabilities) Property name Property implementation Capabilities SMX_SASStorageCapabilities ManagedElement SMX_SASPrimordialPoolNoRaid SMX_SASStoragePoolStorageCapabilities (Association) 6-1-38 Table 6-38 Class: SMX_SASStoragePoolStorageCapabilities (CIM_ElementCapabilities ) Property name Property implementation Capabilities...
  • Page 183: Smx_Sasarraysystemdiskdrive (Association)

    Table 6-40 Class: SMX_SASArraySystemPortController (CIM_Logicaldentity) Property name Property implementation SameElement SMX_SASArraySystem SystemElement SMX_SASPortController SMX_SASArraySystemDiskDrive (Association) 6-1-41 Table 6-41 Class: SMX_SASArraySystemDiskDrive (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASDiskDrive SMX_SASArraySystemStorageVolume (Association) 6-1-42 Table 6-42 Class: SMX_SASArraySystemStorageVolume (CIM_SystemDevice) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent...
  • Page 184: Smx_Sasarraysystemprimordialpool (Association)

    SMX_SASArraySystemPrimordialPool (Association) 6-1-45 Table 6-45 Class: SMX_SASArraySystemPrimordialPool (CIM_HostedStoragePool) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASPrimordialPool SMX_SASArraySystemPrimordialPoolNoRaid 6-1-46 (Association) Table 6-46 Class: SMX_SASArraySystemPrimordialPoolNoRaid (CIM_HostedStoragePool) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASPrimordialPoolNoRaid SMX_SASArraySystemStoragePool (Association) 6-1-47 Table 6-47 Class: SMX_SASArraySystemStoragePool (CIM_HostedStoragePool) Property name Property implementation GroupComponent...
  • Page 185: Smx_Sasproductphysicalpackage (Association)

    Table 6-49 Class: SMX_SASArraySystemArrayController (CIM_ComponentCS) Property name Property implementation GroupComponent SMX_SASArraySystem PartComponent SMX_SASArrayController SMX_SASProductPhysicalPackage (Association) 6-1-50 Table 6-50 Class: SMX_SASProductPhysicalPackage (CIM_ProductPhysicalPackage) Property name Property implementation GroupComponent SMX_SASProduct PartComponent SMX_SASPhysicalPackage SMX_SASStoragePoolStorageExtent (Association) 6-1-51 Table 6-51 Class: SMX_SASStoragePoolStorageExtent (CIM_ConcreteComponent) Property name Property implementation GroupComponent SMX_SASStoragePool PartComponent...
  • Page 186: Smx_Sasarraysystemfirmware (Association)

    Table 6-53 Class: SMX_SASPrimordialPoolNoRaidStorageExtent (CIM_ConcreteComponent) Property name Property implementation PartComponent SMX_SASStorageExtent SMX_SASStorageSpecificCollectionArraySystem 6-1-54 (Association) Table 6-54 Class: SMX_SASStorageSpecificCollectionArraySystem (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SASStorageSpecificCollection Member SMX_SASArraySystem SMX_SASStorageRedundancySetStorageExtent 6-1-55 (Association) Table 6-55 Class: SMX_SASStorageRedundancySetStorageExtent (CIM_MemberOfCollection) Property name Property implementation Collection SMX_SASStorageRedundancySet Member SMX_SASStorageExtent...
  • Page 187: Smx_Sasfirmwarearraysystem (Association)

    Table 6-57 Class: SMX_SASSCSIProtocolControllerStorageVolume (CIM_ProtocolControllerForUnit) Property name Property implementation Antecedent SMX_SASSCSIProtocolController Dependent SMX_SASStorageVolume DeviceNumber Device LUN number DeviceAccess 2 (Read Write) SMX_SASFirmwareArraySystem (Association) 6-1-58 Table 6-58 Class: SMX_SASFirmwareArraySystem (CIM_ElementSoftwareIdentity) Property name Property implementation Antecedent SMX_SASFirmware Dependent SMX_SASArraySystem ElementSoftwareStatus • ElementSoftwareStatus[0]: 2 (Current) •...
  • Page 188: Smx_Sasprimordialpoolstoragepool (Association)

    Table 6-61 Class: SMX_SASStoragePoolStorageVolume (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent SMX_SASStoragePool Dependent SMX_SASStorageVolume SpaceConsumed Bytes consumed by volume SMX_SASPrimordialPoolStoragePool (Association) 6-1-62 Table 6-62 Class: SMX_SASPrimordialPoolStoragePool (CIM_AllocatedFromStoragePool) Property name Property implementation Antecedent SMX_SASPrimordialPool Dependent SMX_SASStoragePool SpaceConsumed Bytes consumed by storage pool SMX_SASSpareExtentStorageRedundancySet 6-1-63 (Association)
  • Page 189: Smx_Sasstoragegrouphostedcollection (Association)

    Table 6-65 Class: SMX_SASDAPortSCSIProtocolEndpoint (CIM_DeviceSAPImplementation) Property name Property implementation Antecedent SMX_SASDAPort Dependent SMX_SASSCSIProtocolEndpoint SMX_SASStorageGroupHostedCollection (Association) 6-1-66 Table 6-66 Class: SMX_SASStorageGroupHostedCollection (HP_GroupHostedCollection) Property name Property implementation Antecedent HP_ComputerSystem Dependent SMX_SASStorageSpecificCollection SMX_SASPhysicalPackageArraySystem (Association) 6-1-67 Table 6-67 Class: SMX_SASPhysicalPackageArraySystem (CIM_ComputerSystemPackage) Property name Property implementation Antecedent SMX_SASPhysicalPackage Dependent...
  • Page 190: Sas Hba Status Ok

    Table 6-69 Class: SMX_SASDiskPhysicalPackageDiskDriveLocation (CIM_PhysicalElementLocation) Property name Property implementation Element SMX_SASDiskPhysicalPackage PhysicalLocation SMX_SASDiskDriveLocation SMX_SASSCSIProtocolEndpointSCSIProtocolController 6-1-70 (Association) Table 6-70 Class: SMX_SASSCSIProtocolEndpointSCSIProtocolController (CIM_SAPAvailableForElement) Property name Property implementation AvailableSAP SMX_SASSCSIProtocolEndpoint ManagedElement SMX_SASSCSIProtocolController Supported indications SAS HBA status OK 6-2-1 Table 6-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation CIM_Indication...
  • Page 191 Table 6-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary HBA status OK EventCategory 11 (I/O Adapter) ProbableCause 1 (Other) ProbableCauseDescription HBA Status Changed to OK ProviderVersion...
  • Page 192: Sas Hba In Error State

    Table 6-71 HP_DeviceIndication: SAS HBA status OK Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Controller firmware version string...
  • Page 193 Table 6-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary HBA status Error EventCategory 11 (I/O Adapter) ProbableCause 2 (Adapter/Card Error) ProbableCauseDescription HBA Status Changed to Error ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
  • Page 194: Physical Drive Status Ok

    Table 6-72 HP_DeviceIndication: SAS HBA in Error state Property name Property implementation SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWFirmwareVersion Controller firmware version string...
  • Page 195 Table 6-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical Drive Status is now OK EventCategory 6 (Primary Storage) ProbableCause 1 (Other) ProbableCauseDescription Physical Drive Status Changed to OK ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
  • Page 196: Physical Drive Status Error

    Table 6-73 HP_DeviceIndication: Physical Drive status OK Property name Property implementation BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 197 Table 6-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation ProviderName HP SAS RecommendedActions Check for failed or removed physical drives. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication HP_AlertIndication Summary Physical drive status Error...
  • Page 198: Physical Drive Status Rebuilding

    Table 6-74 HP_DeviceIndication: Physical Drive status ERROR Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name...
  • Page 199 Table 6-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation AlertingMangedElement WBEM Path of disk drive AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions No action is recommended.
  • Page 200: Physical Drive Status Predictive Failure

    Table 6-75 HP_DeviceIndication: Physical Drive status REBUILDING Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 201 Table 6-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation IndicationTime Time of indication CIM_AlertIndication Description A physical drive status has changed to Predictive Failure. AlertingMangedElement WBEM Path of disk drive AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown...
  • Page 202: Logical Drive Status Ok

    Table 6-76 HP_DeviceIndication: Drive status PREDICTIVE FAILURE Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “”...
  • Page 203 Table 6-77 HP_DeviceIndication: Logical Drive status OK Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of indication PreceivedSeverity 2 (Informational) IndicationTime Time of indication CIM_AlertIndication Description A logical drive status has changed from non-OK to OK. AlertingMangedElement WBEM Path of Storage Volume AlertingElementFormat...
  • Page 204: Logical Drive Status Error

    Table 6-77 HP_DeviceIndication: Logical Drive status OK Property name Property implementation SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the...
  • Page 205 Table 6-78 HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Check for failed or removed physical drives. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating the indication...
  • Page 206: Logical Drive Status Degraded

    Table 6-78 HP_DeviceIndication: Logical Drive status ERROR Property name Property implementation BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName * HP_ComputerSystem.Name EnclosureName * HP_BladeEnclosureCS.Name RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID...
  • Page 207 Table 6-79 HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation HP_AlertIndication Summary Logical drive degraded state EventCategory 6 (Primary Storage) ProbableCause 86 (Disk Failure) ProbableCauseDescription Logical Drive State Changed to Degraded ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
  • Page 208: Enclosure Power Supply Status Changed To Non Redundant

    Table 6-79 HP_DeviceIndication: Logical Drive is in a degraded state Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment Enclosure Power Supply status changed to Non 6-2-10 Redundant Table 6-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation...
  • Page 209 Table 6-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation NetworkAddresses List of all the IP addresses of the computer system generating the indication OSType • For Windows 2003 32-bit: 69 • For Windows 2003 64-bit: 70 •...
  • Page 210: Enclosure Power Supply Status Changed To Ok (Redundant)

    Table 6-80 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant Property name Property implementation HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication DeviceModel Enclosure Model string Enclosure Power Supply Status changed to OK 6-2-11 (Redundant) Table 6-81...
  • Page 211 Table 6-81 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build> NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType •...
  • Page 212: Enclosure Power Supply Status Changed To Redundant Degraded

    Table 6-81 HP_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant) Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication HWLogicalLocation Enclosure Location string For example, Port 1I Box 1 HWSerialNumber Enclosure Serial Number HP_DeviceIndication...
  • Page 213 Table 6-82 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation Summary Power supply status Redundant Degraded EventCategory 17 (Primary Storage Power) ProbableCause 89 (Power supply failure) ProbableCauseDescription Redundant Power Supply Degraded ProviderVersion Provider version generating the indication in the format, <major>.<minor>.<revision>.<build>...
  • Page 214: Enclosure Temperature Sensor Status Changed To Ok

    Table 6-82 HP_DeviceIndication: Enclosure Power Supply status changed to Redundant Degraded Property name Property implementation RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment...
  • Page 215 Table 6-83 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation HP_AlertIndication Summary Temperature sensor status OK EventCategory 24 (Primary Storage Cooling) ProbableCause 1 (Other) ProbableCauseDescription Temperature Status Changed to OK NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of the computer system generating the indication OSType •...
  • Page 216: Enclosure Temperature Sensor Status Changed To Warning

    Table 6-83 HP_DeviceIndication: Enclosure Temperature sensor status changed to OK Property name Property implementation RackName * Rack name if one exists RackUID * Rack Unique Identifier if one exists SystemVirtualSerialNumber Conditional property containing the virtual system serial number string when running in a Virtual Connect environment SystemVirtualUUID Conditional property containing the virtual system...
  • Page 217 Table 6-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow. Add or repair fans and air baffling if necessary. SystemName Name of the computer system generating the indication SystemCreationClassName CreationClassName of the computer system generating...
  • Page 218: Enclosure Temperature Sensor Status Changed To Critical

    Table 6-84 HP_DeviceIndication: Enclosure Temperature sensor status changed to Warning Property name Property implementation ImpactedDomain • 3 (Enclosure) for c-Class blade systems • 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated. BladeBay * HP_BladeCSLocation.LocationInformation[0] BladeName *...
  • Page 219 Table 6-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
  • Page 220: Enclosure Fan Status Changed To Ok

    Table 6-85 HP_DeviceIndication: Enclosure Temperature sensor status changed to Critical Property name Property implementation VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 221 Table 6-86 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation AlertingMangedElement WBEM Path of SMX_SASStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID EventTime Time of the event or time of the indication if event time unknown ProviderName HP SAS RecommendedActions...
  • Page 222: Enclosure Fan Status Changed To Degraded

    Table 6-86 HP_DeviceIndication: Enclosure Fan status changed to OK Property name Property implementation VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “” values. ImpactedDomain • 3 (Enclosure) for c-Class blade systems •...
  • Page 223 Table 6-87 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation Description A Storage Enclosure Fan status has changed to Degraded. An enclosure has detected there might be a problem with one or more of the fans. AlertingMangedElement WBEM Path of SMX_SASStorageEnclosureProcessor AlertingElementFormat 2 (CIMObjectPath)
  • Page 224: Enclosure Fan Status Change To Failure

    Table 6-87 HP_DeviceIndication: Enclosure Fan status changed to Degraded Property name Property implementation SystemModel Model name of the computer system generating the indication SystemGUID Platform GUID of the computer system generating the indication VariableNames FailureDescription VariableTypes 1 (String) VariableValues Short Description of failure In some cases, the property VariableValues can have N/A or “”...
  • Page 225 Table 6-88 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation PerceivedSeverity 5 (major) IndicationTime Time of indication CIM_AlertIndication Description A Storage Enclosure Fan Status changed to Failure. An enclosure has detected a failure in the fan subsystem and there is insufficient fan capability to ensure normal operation.
  • Page 226 Table 6-88 HP_DeviceIndication: Enclosure Fan status changed to Failure Property name Property implementation SystemFirmwareVersion Firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the indication SystemProductID Product ID of the computer system generating the indication SystemModel Model name of the computer system generating the...
  • Page 227: Smx_Computersystem

    Base Server Overview The SMX Base Server provider implements and extends CIM classes described in this document to model the base server. These classes provide computational information and capabilities and serve as an aggregation point to associate one or more elements that make up a base server, such as: Fans, Power Supplies, Processor and Memory (Volatile and/or Non-Volatile Storage).
  • Page 228 Table 7-2 Class: SMX_ComputerSystem Properties Property name Property implementation CIM_ManagedElement Caption Computer system DNS name returned by uname Description Computer system DNS name returned by uname ElementName Computer system DNS name returned by uname CIM_ManagedSystemElement Status Same as OpertionaStatus (0) OperationalStatus OperationalStatus[0] contains the computer system consolidated status and indicates the worst status of...
  • Page 229 Table 7-2 Class: SMX_ComputerSystem Properties StatusDescriptions StatusDescriptions[0] contains one of the following corresponding to OperationalStatus[0]: • One or more of the subsystems that make up this computer system have an OperationalStatus value of Unknown. • One or more of the subsystems that make up this computer system have an OperationalStatus value of Other.
  • Page 230 Table 7-2 Class: SMX_ComputerSystem Properties OtherIdentifyingInfo OtherIdentifyingInfo[0]: <GUID_String> where <GUID_String> is the computer system physical GUID string OtherIdentifyingInfo[1]: <MAC_String> where <MAC_String> is the computer system MAC address OtherIdentifyingInfo[2]: <Model_String>:<Serial Number String> where <Model_String> is the computer system model string; and <Serial Number String> is the computer system physical serial number string OtherIdentifyingInfo[3]: <Tag_String>...
  • Page 231 Table 7-2 Class: SMX_ComputerSystem Properties PrimaryOwnerName Computer system primary owner name string; initialized to not set. PrimaryOwnerContact Computer system primary owner contact string; initialized to not set). PrimaryOwnerPager Computer system primary owner pager string; initialized to not set. SecondaryOwnerContact Computer system secondary owner contact string; initialized to not set.
  • Page 232: Smx_Computersystemchassis

    SMX_ComputerSystemChassis 7-3-2 SMX_ComputerSystemChassis implements the class HP_ComputerSystemChassis to model the physical system chassis. There is only one instance of SMX_ComputerSystemChassis instantiated on a server. Table 7-4 Class: SMX_ComputerSystemChassis Property name Property implementation CIM_PhysicalElement Unique value for instance, for example 1 CreationClassName SMX_ComputerSystemChassis ElementName...
  • Page 233: Smx_Computersystempackage

    Table 7-4 Class: SMX_ComputerSystemChassis Property name Property implementation VirtualUUID[] If Synergy is enabled, this will contain the logical UUID for the system. VirtualSerialNumber If Synergy is enabled, this will contain the logical Serial Number for the system. SMX_ComputerSystemChassis SMX_ComputerSystemPackage 7-3-3 SMX_ComputerSystemPackage implements the class HP_ComputerSystemPackage and associates instances of SMX_ComputerSystem and SMX_ComputerSystemChassis.
  • Page 234: Smx_Runningos

    Table 7-6 Class: SMX_OperatingSystem Property name Property implementation StatusDescriptions StatusDescriptions[0] will contain the value map string corresponding to OperationalStatus[0]: For example: OK Status HealthState 5 (OK) PrimaryStatus 1 (OK) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled) RequestedState 0 (Unknown) EnabledDefault 2 (Enabled) TransitioningToState 12 (Not Applicable) CIM_OperatingSystem...
  • Page 235: Smx_Installedos

    Table 7-7 Class: SMX_RunningOS Property name Property implementation Dependent ref: CIM_ComputerSystem SMX_RunningOS SMX_InstalledOS 7-3-6 SMX_InstalledOS implements the class CIM_InstalledOS and associates the SMX_ComputerSystem instance and an SMX_OperatingSystem instance. Table 7-8 Class: SMX_InstalledOS Property name Property implementation CIM_InstalledOS PartComponent ref: CIM_OperatingSystem GroupComponent ref: CIM_ComputerSystem SMX_InstalledOS...
  • Page 236 The first numeric value in the VersionString MinorVersion The second numeric value in the VersionString RevisionNumber The third numeric value in the Versionstring VersionString Version of SMX, for example, 02.00.00 Manufacturer Hewlett-Packard Classifications[0] 5 (Instrumentation) IsEntity True TargetOSTypes[0] On ESX, 39(VM) On Linux, 36 (Linux)
  • Page 237: Smx_Smxinstalledsoftwareidentity

    Table 7-10 Class: SMX_SoftwareIdentity Property name Property implementation SMX_SMXSoftwareIdentity SMX_SMXInstalledSoftwareIdentity 7-3-9 SMX_SMXInstalledSoftwareIdentity implements the class CIM_InstalledSoftwareIdentity and associates the SMX_ComputerSystem instance and an SMX_SMXSoftwareIdentity instance. Table 7-11 Class: SMX_SMXInstalledSoftwareIdentity Property name Property implementation CIM_InstalledSoftwareIdentity InstalledSoftware ref: CIM_SoftwareIdentity System ref: CIM_ComputerSystem SMX_SMXInstalledSoftwareIdentity SMX_SystemFirmware 7-3-10...
  • Page 238: Smx_Systeminstalledfirmwareidentity

    For example, HPQ:SMX_SystemFirmware:1 MajorVersion The firmware major version MinorVersion The firmware minor version VersionString The firmware version Manufacturer Hewlett-Packard Classifications 11 (Bios/FCode) ClassificationDescriptions System Firmware IdentityInfoValue On ProLiant, this will contain: HPQ:<family_code> where <family_code> is the system ROM family code...
  • Page 239: Smx_Systemelementfirmwareidentity

    SMX_SystemElementFirmwareIdentity 7-3-12 HP_SystemElementFirmwareIdentity implements the class HP_ElementSoftwareIdentity and associates the HP_ComputerSystem instance and SMX_SystemFirmware instances. Table 7-14 Class: SMX_SystemElementFirmwareIdentity Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity UpgradeCondition 3 (Owner Upgradeable) ElementSoftwareStatus The ElementSoftwareStatus array will contain the following if the Antecedent refers to an instance of an Active Firmware: ElementSoftwareStatus[0]: 6 (Installed)
  • Page 240: Hp_Deviceindication: Wbem Providers Started

    Table 7-15 Provider Indication Common Properties Property name Property implementation HP_AlertIndication ProviderVersion Provider Version in the format VV.UU.FF. for example, 01.05.00 NetworkAddresses Contains a list of all the IP addresses of the computer system generating the indication OSType On ESX, 39 (VM) On Linux, 36 (Linux) OSVersion The operating system version of the computer system...
  • Page 241: Hp_Deviceindication: Wbem Providers Informational Test Indication

    Table 7-16 HP_DeviceIndication: WBEM Providers Started Property name Property implementation ProbableCause 1 (Other) ProbableCauseDescription WBEM Providers Started HP_DeviceIndication: WBEM Providers 7-4-2 Informational Test Indication Table 7-17 HP_DeviceIndication: WBEM Providers Informational Test Indication Property name Property implementation CIM_Indication PerceivedSeverity 2 (Informational) CIM_AlertIndication Description This is an information test event...
  • Page 242: Hp_Deviceindication: Wbem Providers Critical Test Indication

    HP_DeviceIndication: WBEM Providers Warning 7-4-3 Test Indication Table 7-18 HP_DeviceIndication: WBEM Providers Warning Test Indication Property name Property implementation EventID ProviderName HP Test RecommendedActions No action is recommended. HP_AlertIndication Summary Test Event ProbableCause 1 (Other) ProbableCauseDescription Test Indication HP_DeviceIndication: WBEM Providers Critical Test 7-4-4 Indication Table 7-19...
  • Page 243: Hp_Deviceindication: Asr Reboot Occurred

    HP_DeviceIndication: ASR Reboot Occurred 7-4-5 Table 7-20 HP_DeviceIndication: ASR Reboot Occurred Property name Property implementation CIM_Indication PerceivedSeverity 5 (Warning) CIM_AlertIndication Description “The system has rebooted from an Automatic Server Recovery (ASR) event.” AlertType 5 (Device Alert) EventID “1” ProviderName “HP Recovery” RecommendedActions “Determine the nature of the ASR event and take corrective action.”...
  • Page 244: Hp_Deviceindication: Post Occurred

    HP_DeviceIndication: Thermal Reboot Occurred 7-4-6 Table 7-21 HP_DeviceIndication: Thermal Reboot Occurred Property name Property implementation RecommendedActions “Replace any failed or removed fans. Insure the air flow into, out of, and within the system chassis is not obstructed.” HP_AlertIndication Summary “Thermal reboot occurred.” EventCategory 16 (System Power) ProbableCause...
  • Page 245 HP_DeviceIndication: POST Occurred 7-4-7 Table 7-22 HP_DeviceIndication: POST Occurred Property name Property implementation VariableTypes VariableTypes[0]: 3 (uint8) VariableTypes[1]: 1 (string) VariableValues VariableValues[0]: The POST error code as specified by the System ROM VariableValues[1]: The POST error string as specified by the System ROM Base Server 245...
  • Page 246: Smx_Processor

    Overview The following table details these profiles implemented and files installed by this provider. Table 7-1 Overview Implemented Profiles HP CPU Profile (P00106) HP CPU Consolidated Status Profile (P00107) HP CPU Physical Asset Profile (P00108) HP Location Profile (P00124) Namespaces This provider returns instances in the root/hpq namespace.
  • Page 247 Table 7-2 Class: HP_Processor Properties Property name Property implementation CIM_ManagedElement Caption Processor in ProcessorBaord=a, where a is the slot number Processor in CPUSocket=b on System Mainboard, where b is the socket number Processor in Socket=b on ProcessorBaord=a where a is the slot number and b is the socket number Description <processor brand string>...
  • Page 248 Table 7-2 Class: HP_Processor Properties Property name Property implementation HealthState 0 (Unknown), when OperationalStatus[0]=0 (Unknown) 5 (OK), when OperationalStatus[0]=2 (OK) 15 (Minor Failure), when OperationalStatus[0]=10 (Stopped) 20 (Major Failure), when OperationalStatus[0]=5 (Predictive Failure) 25 (Critical Failure), when OperationalStatus[0]=6 (Error) CIM_LogicalElement CIM_EnabledLogicalElement EnabledState 2 (Enabled)
  • Page 249: Smx_Processorcapabilities

    Table 7-2 Class: HP_Processor Properties Property name Property implementation NumberOfEnabledCores Number of enabled and operational cores for this processor (for example, 1, 2, 4) Stepping Stepping for processor Role Processor Role Unique ID Unique identifier for processor HP_Processor SMX_Processor SMX_ProcessorCapabilities 8-3-2 SMX_ProcessorCapabilities extends the class CIM_ProcessorCapabilities to model the processor capabilities.
  • Page 250 Table 8-4 Class: SMX_ProcessorCore Property name Property implementation CIM_ManagedElement Caption Processor:p - Core:c, where p is the processor number and c is the core number Description <processor brand string> (x86 Family x Model y Stepping z) (Processor:p - Core:c), where <processor brand string>...
  • Page 251: Smx_Hardwarethread

    Table 8-4 Class: SMX_ProcessorCore Property name Property implementation CIM_ProcessorCore InstanceID HPQ:SMX_ProcessorCore:Proc:p Core:c, where p is the processor number and c is the core number. CoreEnabledState 2 (Core Enabled) Characteristics For x86 processors: Characteristics[0]: 3 (32-bit Capable) For x64 processors: ○ Characteristics[0]: 3 (32-bit Capable) ○...
  • Page 252: Smx_Cachememory

    Table 8-5 Class: SMX_HardwareThread Property name Property implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when CPU is disabled through POST error 10 (Stopped), when CPU is disabled through RBSU StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]:...
  • Page 253 Table 8-6 Class: SMX_CacheMemory Property name Property implementation Caption One of the following: Level x Data Cache, where x is the cache level number Level x Insturction Cache, where x is the cache level number Level x Unified Cache, where x is the cache level number Examples: Level 1 Data Cache...
  • Page 254: Smx_Systemprocessor

    Table 8-6 Class: SMX_CacheMemory Property name Property implementation CIM_EnabledLogicalElement EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) EnabledDefault 2 (Enabled) CIM_LogicalDevice SystemCreationClassName SMX_ComputerSystem SystemName Computer system name CreationClassName SMX_CacheMemory DeviceID One of the following: Proc p, Level x <type> Cache, where p is the processor number, x is the cache level number, and <type>...
  • Page 255: Smx_Processorelementcapabilities

    Table 8-7 Class: SMX_SystemProcessor Property name Property implementation HP_SystemProcessor SMX_SystemProcessor GroupComponent ref: SMX_ComputerSystem PartComponent ref: SMX_Processor SMX_ProcessorElementCapabilities 8-3-7 SMX_ProcessorElementCapabilities extends the class CIM_ElementCapabilities and associates SMX_Processor instances and SMX_ProcessorCapabilities instances. Table 8-8 Class: HP_ProcessorElement Capabilities Property name Property implementation CIM_ElementCapabilities HP_ProcessorElementCapabilities SMX_ProcessorElementCapabilities ManagedElement...
  • Page 256: Smx_Associatedprocessorcachememory

    Table 8-10 Class: SMX_HWThreadComponent Property name Property implementation CIM_Component CIM_ConcreteComponent HP_HWThreadComponent SMX_HWThreadComponent GroupComponent ref: SMX_ProcessorCore PartComponent ref: SMX_HardwareThread SMX_AssociatedProcessorCacheMemory 8-3-10 SMX_AssociatedProcessorCacheMemory extends the class CIM_AssociatedCacheMemory. SMX_AssociatedProcessorCacheMemory associates an SMX_Processor instance with an SMX_CacheMemory instance. Table 8-11 Class: SMX_AssociatedProcessorCacheMemory Property name Property implementation CIM_Dependency CIM_AssociatedMemory...
  • Page 257: Smx_Processorcollection

    Table 8-11 Class: SMX_AssociatedProcessorCacheMemory Property name Property implementation Read Policy 0 (Unknown) 1 (Other) 2 (Read) 3 (Read-Ahead) 4 (Read and Read-Ahead) 5 (Determination Per I/O) Associativity 0 (Unknown) 1 (Other) 2 (Direct Mapped) 3 (2-way Set-Associative) 4 (4-way Set-Associative) 5 (Fully Associative) 6 (8-way Set-Associative) 7 (16-way Set-Associative)
  • Page 258: Smx_Hostedprocessorcollection

    Table 8-12 Class: SMX_ProcessorCollection Property name Property implementation GroupOperationalStatus GroupOperationalStatus[0] contains the processors consolidated status. GroupOperationalStatus[0] will contain one of the following: 0 (Unknown) 1 (Other) 2 (OK) 3 (Degraded) 5 (Predictive Failure) 6 (Error) 10 (Stopped) The status values of the processors that make up the overall group operational status are contained in GroupOperationalStatus[1-n].
  • Page 259: Smx_Memberofprocessorcollection

    Table 8-13 Class: SMX_HostedProcessorCollection Property name Property implementation SMX_HostedProcessorCollection Antecedent ref: SMX_ComputerSystem Dependent ref: SMX_ProcessorCollection SMX_MemberOfProcessorCollection 8-3-13 SMX_MemberOfProcessorCollection extends the class CIM_MemberOfCollection and associates the SMX_ProcessorCollection instance with an SMX_Processor instance. Table 8-14 Class: SMX_MemberOfProcessorCollection Property name Property implementation CIM_MemberOfCollection SMX_MemberOfProcessorCollection Member ref: SMX_Processor...
  • Page 260 Table 8-15 Class: SMX_ProcessorChip Properties Property name Property implementation OperationalStatus 0 (Unknown) 2 (OK), when CPU is enabled and operational 5 (Predictive Failure), when IML error information is logged for this CPU 6 (Error), when CPU is disabled through POST error 10 (Stopped), when CPU is disabled through RBSU StatusDescriptions StatusDescriptions[0] text per OperationalStatus[0]:...
  • Page 261: Smx_Realizesprocessor

    Table 8-15 Class: SMX_ProcessorChip Properties Property name Property implementation ElementName Processor in ProcessorBoard=a” where a is the slot number Processor in CPUSocket=b on System Mainboard” where b is the socket number Processor in CPUSocket=b on ProcessorBoard=a” where a is the slot number and b is the socket number Manufacturer processor manufacturer string from SMBIOS (for example, Intel or AMD)
  • Page 262: Smx_Systemphysicalprocessor

    SMX_SystemPhysicalProcessor 8-3-16 SMX_SystemPhysicalProcessor extends the class CIM_Container and associates the SMX_ComputerSystemChassis instance with SMX_ProcessorChip instances. Table 8-17 Class: HP_SystemPhysicalProcessor Property name Property implementation CIM_Component CIM_Container HP_SystemPhysicalProcessor SMX_SystemPhysicalProcessor GroupComponent ref: SMX_ComputerSystemChassis PartComponent ref: SMX_ProcessorChip SMX_ProcessorLocation 8-3-17 SMX_ProcessorLocation implements the class HP_Location which extends the class CIM_Location. For ProLiant systems, processor location is denoted by the use of a slot number designator and a socket number designator.
  • Page 263 Table 8-18 Class: SMX_ProcessorLocation Property name Property implementation ElementName Processor in ProcessorBaord=a, where a is the slot number Processor in CPUSocket=b on System MainBoard, where b is the socket number Processor in CPUSocket=b on ProcessorBoard=a where a is the slot number and b is the socket number CIM_Location Name HPQ:SMX_ProcessorLocation:a, where a is the slot...
  • Page 264: Smx_Processorelementlocation

    Table 8-18 Class: SMX_ProcessorLocation Property name Property implementation LocationInfoDesc If only socket number is available, LocationInfoDesc[0]: 4 (Socket), indicates that the first element of the LocationInformation array contains the socket number If only slot number is available, LocationInfoDesc[0]: 0 (Slot), indicates that the first element of the LocationInformation array contains the slot number If both socket and slot numbers are available, LocationInfoDesc[0]:...
  • Page 265: Hp_Deviceindication: Processor Failed Post

    Table 7-20 Provider Indication Common Properties Property name Property implementation IndicationIdentifier GUID string generated at the time of indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName SMX_ComputerSystem.CreationClassName HP_AlertIndication...
  • Page 266: Hp_Deviceindication: Processor Disabled By Bios Or Efi

    HP_DeviceIndication: Processor Failed Post 8-4-1 Table 8-21 HP_DeviceIndication: Processor Failed Post Property name Property implementation AlertType 5 (Device Alert) EventID EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replaced the failed processor HP_AlertIndication Summary CPU Failed Power on Self Test (POST) ProbableCause 1 (Other) HP_DeviceIndication: Processor Disabled by BIOS...
  • Page 267: Hp_Deviceindication: Processor Predicted To Fail

    HP_DeviceIndication: Processor Predicted to fail 8-4-3 Table 8-23 HP_DeviceIndication: Processor Predicted to fail Property name Property implementation CIM_Indication PerceivedSeverity 4 (Minor) CIM_AlertIndication Description CPU Predictive Failure Notification AlertType 5 (Device Alert) EventID EventCategory 2 (Processor) ProviderName HP Processor RecommendedActions Replace the failing processor. HP_AlertIndication Summary CPU Predictive Failure detected...
  • Page 268: System Fan

    System Fan Overview The SMX System Fan provider implements the classes listed to support fans installed in servers. The following table details the profiles implemented and files installed by this provider. Table 8-1 Overview Implemented Profiles HP Fan Profile 1.0 (P102) HP Location Profile 1.0 (P124) HP Fan Physical Location Profile 1.0 (P115) Namespaces...
  • Page 269: Smx_Fan

    SMX_Fan 9-3-1 SMX_Fan is used to model fans on Servers. Please note: fan numbers for existing instances do not change when other fans are added and removed. Table 9-2 Class: SMX_Fan Property name Property implementation CIM_ManagedElement Caption Short description of this fan from the name displayed by the MP or iLO and the location.
  • Page 270: Smx_Fancollection

    Table 9-2 Class: SMX_Fan Property name Property implementation SystemName SMX_ComputerSystem.Name CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_CoolingDevice ActiveCooling True CIM_Fan VariableSpeed True—if fan supports variable speed False—if fan does not support variable speed or is unknown HP_Fan FanType...
  • Page 271: Smx_Fanredundancyset

    Table 9-3 Class: SMX_FanCollection Property name Property implementation GroupOperationalStatus[0] Represents the most severe cooling redundancy status and non-fault tolerant fan operational status: 0 (Unknown)—if fan collection status is unknown 2 (OK)—if fans are operating properly 3 (Degraded)—if no SMX_Fan OperationalStatus[0] for all non-fault tolerant fans report 6 (Error) and SMX_FanRedundancy.RedundancyStatus for any cooling redundancy sets report 3 (Degraded...
  • Page 272: Smx_Memberoffanredundancy

    Table 9-4 Class: SMX_FanRedundancySet Property name Property implementation InstanceID Unique identifier for this cooling redundancy instance CIM_RedundancySet MaxNumberSupported Represents the maximum number of fans supported for this redundancy set MinNumberNeeded Represents the minimum number of fans needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm 0 (Unknown)
  • Page 273: Smx_Memberoffancollection

    SMX_MemberOfFanCollection 9-3-6 SMX_MemberOfFanCollection is used to represent an association between HP_Fan and HP_FanCollection. Table 9-7 Class: SMX_MemberOfCoolingCollection Property name Property implementation Collection References HP_FanCollection Member References HP_Fan SMX_HostedFanCollection 9-3-7 SMX_HostedFanCollection is used to represent an association between HP_FanCollection and the computer system that contains this collection.
  • Page 274: Smx_Fanelementlocation

    Table 9-10 Class: SMX_FanLocation Property name Property implementation Description Description of the fan location including the name displayed by the MP or iLO. For example: The location of the fan Fan 1. Please refer to the fan position CabinetFan=01 printed on the system.
  • Page 275: Smx_Systemphysicalfan

    Table 9-12 Class: SMX_FanModule Property name Property implementation Caption Short description of this fan from the name displayed by the MP or iLO and the location. For example: Fan 1 at CabinetFan=01 Description Fan n provides cooling for FanType. StatusDescription where n represents the number of the fan instance, FanType represents the corresponding string value of the FanType enumeration and StatusDescription...
  • Page 276: Smx_Realizesfan

    Table 9-13 Class: SMX_SystemPhysicalFan Property name Property implementation GroupComponent References HP_ComputerSystemChassis PartComponent References HP_FanModule SMX_RealizesFan 9-3-13 The SMX_RealizesFan class implements the HP_RealizesFan class and associates the HP_Fan instance with HP_FanModule instances. Table 9-14 Class: SMX_RealizesFan Property name Property implementation Antecedent References HP_FanModule Dependent References HP_Fan...
  • Page 277: Smx_Faninslot

    Table 9-15 Class: SMX_FanSlot Property name Property implementation ConnectorLayout 6 (Slot) Number Where n represents the number of the fan slot SMX_SystemFanSlot 9-3-15 SMX_SystemFanSlot class implements the HP_SystemFanSlot class and associates the HP_ComputerSystemChassis instance with HP_FanSlot. Table 9-16 Class: SMX_SystemFanSlot Property name Property implementation GroupComponent...
  • Page 278: Smx_Systemfansensor

    Table 9-18 Class: SMX_FanSpeedSensor Property name Property implementation ElementName Short description of this fan speed sensor from the name displayed by the MP or iLO and the location. For example: Fan speed sensor for Fan 1 at CabinetFan=01 CIM_Managed SystemElement OperationalStatus[0] 2 (OK) –...
  • Page 279: Smx_Associatedfansensor

    Table 9-19 Class: SMX_SystemFanSensor Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_FanSpeedSensor SMX_AssociatedFanSensor 9-3-19 The SMX_AssociatedFanSensor class implements the HP_AssociatedFanSensor class and associates the HP_FanSpeedSensor instance with HP_Fan instances. Table 9-20 Class: SMX_AssociatedFanSensor Property name Property implementation Antecedent References HP_FanSensor Dependent References HP_Fan...
  • Page 280: Hp_Deviceindication: Fan Removed

    Table 9-21 Provider Indication Common Properties Property name Property implementation OSType On ESX, 39 (VM) On Linux, 36 (Linux) OSVersion Operating system version of the computer system generating the indication in the format, <major>.<minor>.<build> SystemFirmwareVersion Array of firmware version of the computer system generating the indication SystemSerialNumber Serial number of the computer system generating the...
  • Page 281: Hp_Deviceindication: Fan Inserted

    Table 9-22 HP_DeviceIndication: Fan Removed Property name Property implementation ProbableCause 1 (Other) ProbableCauseDescription Fan Removed HP_DeviceIndication: Fan Inserted 9-4-3 Table 9-23 HP_DeviceIndication: Fan Inserted Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fan has been inserted. (FanCaption), where FanCaption is the SMX_Fan.Caption for the fan that has been inserted AlertingManagedElement...
  • Page 282: Hp_Sensorhardwareindication: Fan Repaired

    HP_SensorHardwareIndication: Fan Failed 9-4-4 Table 9-24 HP_SensorHardwareIndication: Fan Failed Property name Property implementation Description A fan has failed. Please check the failed fan and replace if necessary. (FanCaption), where FanCaption is the SMX_Fan.Caption for the fan that has failed AlertingManagedElement WBEM path of the SMX_Fan instance representing the failed fan AlertingElementFormat...
  • Page 283: Hp_Deviceindication: Fan Degraded

    HP_SensorHardwareIndication: Fan Repaired 9-4-5 Table 9-25 HP_SensorHardwareIndication: Fan Repaired Property name Property implementation HP_AlertIndication Summary Fan repaired EventCategory 23 (System Cooling) ProbableCause 1 (Other) ProbableCauseDescription Fan Repaired HP_DeviceIndication: Fan Degraded 9-4-6 The repaired indication is not supported on ProLiant Systems as the fans do not report a degraded status.
  • Page 284: Hp_Deviceindication: Fan Redundancy Reduced

    HP_DeviceIndication: Fan Redundancy Reduced 9-4-7 Table 9-27 HP_DeviceIndication: Fan Redundancy Reduced Property name Property implementation CIM_Indication PerceivedSeverity 2 (Information) CIM_AlertIndication Description A fault tolerant fan is no longer providing cooling for a cooling redundancy set. (RedundancySetCaption), where RedundancySetCaption represents the SMX_FanRedundancySet.Caption for the redundancy set with reduced redundancy.
  • Page 285: Hp_Deviceindication: Fan Redundancy Restored

    HP_DeviceIndication: Fan Redundancy Lost 9-4-8 Table 9-28 HP_DeviceIndication: Fan Redundancy Lost Property name Property implementation AlertingManagedElement WBEM path of the SMX_FanRedundancySet instance representing the redundancy set where redundancy was lost. AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID ProviderName HP Cooling RecommendedActions Check the fan configuration and check the status of the cooling redundancy.
  • Page 286: Hp_Deviceindication: Fan Redundancy Failed

    HP_DeviceIndication: Fan Redundancy Restored 9-4-9 Table 9-29 HP_DeviceIndication: Fan Redundancy Restored Property name Property implementation RecommendedActions No action is recommended. HP_AlertIndication Summary Cooling redundancy has been restored EventCategory 23 (System Cooling) ProbableCause 1 (Other) ProbableCauseDescription Cooling Redundancy has been Restored HP_DeviceIndication: Fan Redundancy Failed 9-4-10 The redundancy failed indication is not supported on ProLiant systems since redundancy...
  • Page 287 HP_DeviceIndication: Fan Redundancy Failed 9-4-10 The redundancy failed indication is not supported on ProLiant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Table 9-30 HP_DeviceIndication: Fan Redundancy Failed Property name Property implementation EventCategory 23 (System Cooling) ProbableCause 88 (Loss of Redundancy)
  • Page 288: Namespaces

    System Power Supply Overview 10-1 The SMX Power Supply provider implements the HP Power Supply profile to model power supplies in systems. The following table details the profiles implemented and files installed by this provider. Table 10-1 Overview Implemented Profiles HP Power Supply Profile 1.0 (P103) HP Location Profile 1.0 (P124) HP Power Supply Physical Asset Profile 1.0 (P116)
  • Page 289: Smx_Powersupply

    • SMX_SystemPowerMeter • SMX_AssociatedPowerMeter SMX_PowerSupply 10-3-1 SMX_PowerSupply is used to model power supplies on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Table 10-2 Class: HP_PowerSupply Property name Property implementation CIM_ManagedElement Caption...
  • Page 290: Smx_Powercollection

    Table 10-2 Class: HP_PowerSupply Property name Property implementation Name Name of this power supply from the name displayed by the MP or iLO and its location. For example, Power Supply 1 at PowerSupplySlot=2 Power supply 1a at PowerSupplySlot=2 TimeOfLastStateChange Time that state last changed for power supply.
  • Page 291: Smx_Powerredundancyset

    Table 10-3 Class: SMX_PowerCollection Property name Property implementation HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Represents the most severe power redundancy status and non-fault tolerant power supply operational status: 0 (Unknown) —If power collection status is unknown 2 (OK) —If power supplies are operating properly 3 (Degraded) —If no SMX_PowerSupply.OperationalStatus[0] for all non- fault tolerant power supplies report 6 (Error) and...
  • Page 292: Smx_Memberofpowerredundancy

    Table 10-4 Class: SMX_PowerRedundancySet Property name Property implementation CIM_SystemSpecificCollection InstanceID Unique identifier for this power redundancy instance CIM_RedundancySet MaxNumberSupported The maximum number of power supplies supported for this redundancy set MinNumberNeeded The minimum number of power supplies needed to function TypeOfSet 3 (Load Balanced) LoadBalanceAlgorithm...
  • Page 293: Smx_Hostedpowerredundancyset

    SMX_HostedPowerRedundancySet 10-3-5 SMX_HostedPowerRedundancySet is used to represent an association between HP_PowerRedundancySet and the computer system that contains this redundancy set. Table 10-6 Class: SMX_HostedPowerRedundancySet Property name Property implementation OwningElement References HP_ComputerSystem OwnedElement References HP_PowerRedundancySet SMX_MemberOfPowerCollection 10-3-6 SMX_MemberOfPowerCollection is used to represent an association between HP_PowerSupply and HP_PowerCollection.
  • Page 294: Smx_Powersupplylocation

    Table 10-9 Class: SMX_PowerSupplyLocation Property name Property implementation GroupComponent References HP_ComputerSystem PartComponent References HP_PowerSupply SMX_PowerSupplyLocation 10-3-9 SMX_Location is used to model power supply locations on servers. Table 10-10 Class: SMX_PowerSupplyLocation Property name Property implementation CIM_ManagedElement Caption Name of this power supply from the name displayed by the MP or iLO and its location.
  • Page 295 Table 10-11 Class: SMX_PowerSupplyElementLocation Property name Property implementation Element References CIM_ManagedElement PhysicalLocation References CIM_Location System Power Supply 295...
  • Page 296: Smx_Powersupplymodule

    SMX_PowerSupplyModule 10-3-11 SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply numbers for existing instances do not change when other power supplies are added and removed. Table 10-12 Class: SMX_PowerSupplyModule Property name Property implementation CIM_ManagedElement Caption Short description of this power supply from the name displayed by the MP or iLO and its location.
  • Page 297: Smx_Systemphysicalpowersupply

    Table 10-12 Class: SMX_PowerSupplyModule Property name Property implementation Unique identifier for this power supply instance PartNumber Part number of the power supply CIM_PhysicalPackage RemovalConditions 0(Unknown) 3 (Removable when off) 4 (Removable when on or off) Package Type 6 (PowerSupply) SMX_SystemPhysicalPowerSupply 10-3-12 SMX_SystemPhysicalPowerSupply class extends the CIM_Container class and association the HP_ComputerSystemChassis instance with HP_PowerSupplyModule.
  • Page 298: Smx_Systempowersupplyslot

    Table 10-15 Class: SMX_PowerSupplySlot Property name Property implementation Description Description of the power supply slot, For example: PowerSupplySlot=2 ElementName Name of the power supply slot, For example: PowerSupplySlot=2 CIM_Managed SystemElement OperationalStatus[0] 2 (OK) – if power supply slot is operating properly StatusDescriptions[0] Power Supply slot is operating properly –...
  • Page 299: Smx_Powersupplyinslot

    OperationalStatus. For example: OK; HealthState 5 (OK) Name Power controller firmware CIM_LogicalElement CIM_SoftwareIdentity InstanceID Opaque key Classifications Hewlett-Packard Company ClassificiationsDescriptions 10 (Firmware) IsEntity Power controller firmware The firmware version string VersionString The firmware major version MajorVersion System Power Supply 299...
  • Page 300: Smx_Powercontrollerelementfirmwareidentity

    Table 10-18 Class: SMX_PowerControllerFirmware Property name Property implementation The firmware minor version MinorVersion The firmware revision number RevisionNumber SMX_PowerControllerElementFirmwareIdentity 10-3-18 The SMX_PowerControllerElementFirmwareIdentity class associates the SMX_ComputerSystem instance with the SMX_PowerControllerFirmware. Table 10-19 Class: SMX_PowerControllerElementFirmwareIdentity Property name Property implementation Antecedent References HP_PowerControllerFirmware Dependent References HP_ComputerSystem UpgradeCondition...
  • Page 301 Table 10-21 Class: SMX_PowerMeter Property name Property implementation Caption Short description of this power utilization sensor using the name of the power supply displayed by the MP or iLO and location. For example: Power utilization sensor for Power Supply 1 at PowerSupplySlot=1 Description Description of this power utilization sensor including the Caption and StatusDescriptions.
  • Page 302: Smx_Systempowermeter

    Table 10-21 Class: SMX_PowerMeter Property name Property implementation SensorType 13 (Power Consumption) CurrentState “Normal” PossibleStates Array may contain the following value: PossibleStates[0] = ”Normal” CIM_NumericSensor CurrentReading Current reading of the power meter BaseUnits 7 (Watts) RateUnits 0 (None) UnitModifier HP_PowerMeter SMX_SystemPowerMeter 10-3-21 The SMX_SystemPowerMeter class associates the SMX_ComputerSystem instance with the...
  • Page 303: Hp_Deviceidentification: Power Supply Removed

    Table 10-23 Provider Indication Common Properties Property name Property implementation CIM_Indication IndicationIdentifier GUID string generated at the time of the indication IndicationTime Time of indication CIM_AlertIndication EventTime Time of the event or time of the indication if event time unknown SystemName SMX_ComputerSystem.Name SystemCreationClassName...
  • Page 304: Hp_Deviceindication: Power Supply Inserted

    Table 10-24 HP_DeviceIdentification: Power Supply Removed Property name Property implementation CIM_AlertIndication Description A power supply has been removed. (Power Supply), where Power Supply is the system power supply that was removed AlertingManagedElement WBEM path of the SMX_WinPowerSupply instance AlertingElementFormat 2 (CIMObjectPath) AlertType 5 (Device Alert) EventID...
  • Page 305: Hp_Deviceindication: Power Supply Failed

    HP_DeviceIndication: Power Supply Inserted 10-4-3 Table 10-25 HP_DeviceIndication: Power Supply Inserted Property name Property implementation Power Supply Summary inserted EventCategory 16 (System Power) ProbableCause 1 (Other) ProbableCauseDescription Power Supply has been Inserted HP_DeviceIndication: Power Supply Failed 10-4-4 Table 10-26 HP_DeviceIndication: Power Supply Failed Property name Property implementation CIM_Indication...
  • Page 306: Hp_Deviceindication: Power Supply Degraded

    HP_DeviceIndication: Power Supply Degraded 10-4-5 Table 10-27 HP_DeviceIndication: Power Supply Degraded Property name Property implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description A power supply has failed. (PowerSupplyCaption) where PowerSupplyCaption is the SMX_PowerSupply.Caption for the power supply that has degraded AlertingMangedElement WBEM path of the SMX_PowerSupply instance representing the degraded power supply AlertingElementFormat...
  • Page 307: Hp_Device Indication: Power Supply Redundancy Reduced

    HP_Device Indication: Power Supply Repaired 10-4-6 Table 10-28 HP_Device Indication: Power Supply Repaired Property name Property implementation AlertType 5 (Device Alert) EventID ProviderName HP Power RecommendedActions No action is recommended. HP_AlertIndication Summary PowerSupplyCaption has been repaired, where PowerSupplyCaption is the HP_WinPowerSupply. Caption for the power supply that has been repaired.
  • Page 308: Hp_Deviceindication: Power Supply Redundancy Lost

    10-4-7 HP_Device Indication: Power Supply Redundancy Reduced Table 10-29 HP_DeviceIndication: Power Supply Redundancy Reduced Property name Property implementation ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Power Redundancy has been Reduced HP_DeviceIndication: Power Supply Redundancy 10-4-8 Lost Table 10-30 HP_DeviceIndication: Power Supply Redundancy Lost Property name Property implementation CIM_Indication...
  • Page 309: Hp_Deviceindication: Power Supply Redundancy Failed

    HP_DeviceIndication: Power Supply Redundancy Failed 10-4-9 This indication is not supported on ProLiant systems since redundancy set failure, which is failure beyond redundancy lost, will cause system shutdown. Table 10-31 HP_DeviceIndication: Power SupplyRedundancy Failed Property name Property implementation CIM_Indication PerceivedSeverity 5 (Major) CIM_AlertIndication Description...
  • Page 310 Table 10-32 HP_DeviceIndication: Power Supply Redundancy Restored Property name Property implementation Description Power redundancy for the system has been restored. (RedundancySetCaption), where RedundancySetCaption is SMX_PowerRedundancySet.Caption of the redundancy set the power redundancy set with restored redundancy AlertingManagedElement WBEM Path of SMX_PowerRedundancySet instance representing the power redundancy set with restored redundancy AlertingElementFormat...
  • Page 311: Class Implementations

    SMX Profile registration provider Overview 11-1 The following table details the profiles implemented and files installed by this provider. Table 10-1 Overview Implemented Profiles • HP Profile Registration Profile (POO100) Namespaces 11-2 This provider returns instances in the root/hpq namespace. Class implementations 11-3 The classes below describe registration of HP profiles.
  • Page 312: Profile Registration

    Table 11-2 Class: SMX_RegisteredProfile Property name Property implementation InstanceID HPQ:n where n is a unique number OtherRegisteredOrganization NULL for DMTF profiles None for SNIA SMI-S storage profiles RegisteredName Table 3 lists the property values for this class RegisteredOrganization 2 (DMTF) for DMTF profiles 11 (SNIA) for SNIA SMI-S storage profiles RegisteredVersion Table 3 lists the property values for this class...
  • Page 313 This is the list of all possible SNIA profiles. Some implementations only support a subset of these profiles, so only those subsets are reported. Table 10-4 Property values of SMX_RegisteredProfile for SNIA Profiles Registered Name Registered version Caption/Description/ElementName SNIA Block Services Block Services 1.3.0 Profile...
  • Page 314 RegisteredName RegisteredVersion Caption/Description/ElementName HP Fan Physical Asset 1.0.0 HP Fan Physical Asset Profile HP Power Supply Physical 1.0.0 HP Power Supply Physical Asset Profile Asset HP CPU Consolidated 1.0.0 HP CPU Consolidated Status Profile Status HP Sensors 1.0.0 HP Sensors Profile HP Record Log 1.0.0b HP Record Log Profile...
  • Page 315 Table 11-5 Class: SMX_RegisteredProfile Property name Property implementation RegisteredName See Table 5 RegisteredOrganization 1 (Other) for HP WBEM TC profiles RegisteredVersion Table 3 lists the property values for this class SMX_RegisteredProfile Table 10-6 Property Values of SMX_RegisteredProfile for HP WBEM TC Profiles Registered Name Registerred version Caption/Description/ElementName...
  • Page 316: Smx_Extendsprofile

    SMX_ExtendsProfile 11-3-2 SMX_ExtendsProfile extends the class CIM_Dependency and associates an extension profile registration and the parent profile it extends. Table 11-7 Class: SMX_ExtendsProfile Property name Property implementation CIM_Dependency HP_ExtendsProfile Antecedent ref: CIM_RegisteredProfile (extended) * Dependent ref: HP_RegisteredProfile (extends) * SMX_ReferencedProfile 11-3-3 SMX_ReferencedProfile extends the class CIM_ ReferencedProfile and associates an HP profile that references another profile when both are registered in the root\Interop namespace.
  • Page 317: Supported Indications

    Supported indications 11-4 There are no indications specific to the profile registration implementation. SMX Profile registration provider 317...
  • Page 318: Use Cases

    System Temperature Sensor Overview 12-1 This provider implements the HP Sensor Profile to model temperature sensors in ProLiant servers. The following table details the profiles implemented and files installed by this provider. Table 11-1 Overview Implemented Profiles HP Sensor Profile 1.0 Use cases 12-2 See HP Sensor Profile for Use Cases.
  • Page 319 Table 11-2 Class: SMX_NumericSensor Property name Property implementation ElementName Temperature Sensor <sensorID>” where <sensorID> is name displayed by MP or iLO. For example: Temperature Sensor Temp 1 CIM_ManagedSystemElement OperationalStatus[0] 2 (OK)—if temperature reported by the sensor is within normal operating range; 2 (OK)—if temperature reported by the sensor has exceeded its non-critical threshold and has set fans to full speed;...
  • Page 320: Smx_Sensorcollection

    Table 11-2 Class: SMX_NumericSensor Property name Property implementation PossibleStates Array can contain any of the following values: PossibleStates[0] = Normal PossibleStates[1] = Critical CIM_NumericSensor CurrentReading Current reading of temperature sensor BaseUnits 2 (Degrees C) RateUnits 0 (None) UnitModifier SupportedThresholds SupportedThresholds[0] = 1 (UpperThresholdNotCritical) if the system will set fans to full speed if the threshold is crossed SupportedThresholds[0] = 3 (UpperThresholdCritical)
  • Page 321: Smx_Memberofsensorcollection

    Table 11-3 Class: SMX_SensorCollection Property name Property implementation Caption Temperature Sensor Collection Description This is a collection of temperature sensors. GroupStatusDescription., where GroupStatusDescription represents the value of the GroupStatusDescriptions[0] property ElementName Temperature Sensor Collection CIM_SystemSpecificCollection InstanceID Unique identifier for this sensor collection instance HP_GroupSystemSpecificCollection GroupOperationalStatus[0] Represents the most severe sensor group operational...
  • Page 322: Smx_Hostedsensorcollection

    SMX_HostedSensorCollection 12-2-5 SMX_HostedSensorCollection implements HP_HostedSensorCollection and is used to represent an association between SMX_SensorCollection and the computer system that contains the collection. Table 11-5 Class: SMX_HostedSensorCollection Property name Property implementation Antecedent References SMX_ComputerSystem Dependent References SMX_SensorCollection SMX_SystemSensor 12-2-6 SMX_SystemSensor implements HP_SystemSensor and is used to represent an association between SMX_NumericSensor and the computer system that contains the sensor.
  • Page 323 Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Property implementation EventTime Time of the event or time of the indication if event time unknown ProviderName System Temperature RecommendedActions Ensure that the system is adequately ventilated. Check for proper room temperature and internal/external airflow.
  • Page 324 Table 11-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded Property name Property implementation VariableValues SMX_NumericSensor UpperThresholdNonCritical, UpperThresholdCritical, or UpperThresholdFatal property value that is set for the temperature sensor detecting the exceeded threshold ImpactedDomain 3 (Enclosure) for c-Class blade systems 4 (System) for all other systems When ImpactedDomain is 3 (Enclosure), the properties indicated with (*) are populated.
  • Page 325 Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation ProviderName HP Temperature RecommendedActions No action is recommended. SystemName HP_ComputerSystem.Name SystemCreationClassName HP_ComputerSystem.CreationClassName HP_AlertIndication Threshold exceeded condition recovery Summary EventCategory 23 (System Cooling) ProbableCause 52 (Threshold Crossed) ProbableCauseDescription Threshold Exceeded Condition has Recovered ProviderVersion 2.2.0.0...
  • Page 326 Table 12-8 HP_AlertIndication: Temperature Sensor Recovery from Threshold Exceeded Property name Property implementation SystemVirtualUUID Conditional property containing the virtual system UUID when running in a Virtual Connect environment System Temperature Sensor 326...
  • Page 327: System Memory

    System memory Overview 13-1 This provider implements the HP Memory Profile and HP Memory Physical Asset Profile to represent system memory in ProLiant systems. See HP Advanced Memory Protection Technologies (TC060104TB) and product documentation for your ProLiant Server (available at http://www.hp.com). The following table details the profiles implemented and files installed by this provider.
  • Page 328: Smx_Memory

    • SMX_MemoryCollection • SMX_HostedMemoryCollection • SMX_MemberOfMemoryCollection • SMX_MemberOfMemoryRedundancySet • SMX_HostedMemoryRedundancySet • SMX_SystemMemoryModuleSlot • SMX_SystemMemoryBoardSlot SMX_Memory 13-2-1 The class SMX_Memory represents logical memory on ProLiant Servers. There is one instance of this class. Table 13-2 Class: SMX_Memory Property name Property implementation CIM_ManagedElement Caption System Memory...
  • Page 329: Smx_Systemmemory

    Table 13-2 Class: SMX_Memory Property name Property implementation Name System Memory CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_Memory DeviceID HPQ:SMX_Memory:000 SystemCreationClassName same value as property SMX_ComputerSystem.CreationClassName SystemName same value as property SMX_ComputerSystem.Name CIM_StorageExtent Access 3 (Read/Write Supported)
  • Page 330: Smx_Memorymodule

    Table 13-3 Class: SMX_SystemMemory Property name Property implementation HP_SystemMemory GroupComponent ref: SMX_ComputerSystem PartComponent ref: SMX_Memory SMX_SystemMemory SMX_MemoryModule 13-2-3 The class SMX_MemoryModule represents a physical memory module on ProLiant Servers. There is an instance of this class for each memory module present in the system. Empty memory module sockets will not be instantiated.
  • Page 331 Table 13-4 Class: SMX_MemoryModule Property name Property implementation HealthState Enumerator indicating the memory module health state: 0 (Unknown), when OperationalStatus[0] = 0 (Unknown) 5 (OK), when OperationalStatus[0] = 2 (OK) 10 (Degraded/Warning), when OperationalStatus[0] = 3 (Degraded) Name Physical Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory...
  • Page 332 Table 13-4 Class: SMX_MemoryModule Property name Property implementation ElementName Physical Memory Module Socket=y on MemoryBoard= x, where: x is the board/cartridge number where the memory module is located y is the memory socket number where the memory module is located Physical Memory Module Socket=y on ProcessorBoard =x, where: x the processor board number where the memory...
  • Page 333: Smx_Memoryboard

    Table 13-4 Class: SMX_MemoryModule Property name Property implementation PositionInRow Position of memory module in a row. This property is conditional, it is populated if the data is available. FormFactor Enumerator indicating the form factor of the memory module. See the MOF file for details. BankLabel String identifying the physically labeled bank where the memory is located.
  • Page 334 Table 13-6 Class: SMX_MemoryBoard Property name Property implementation Caption Physical Memory MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Physical Memory ProcessorBoard=x , where x is the processor board/cartridge number where the memory board is located. CIM_ManagedSystemElement OperationalStatus Enumerator indicating the memory board operational...
  • Page 335 Table 13-6 Class: SMX_MemoryBoard Property name Property implementation ElementName Physical Memory MemoryBoard=x, where x is the board/cartridge number where the memory board is located. Physical Memory ProcessorBoard=x , where x is the processor board/cartridge number where the memory board is located. CIM_PhysicalPackage RemovalConditions Removal conditions of the memory board:...
  • Page 336: Smx_Realizesmemorymodule

    Table 13-7 Memory Board Status Condition OperationalStatus[0] OperationalStatus[1] StatusDescriptions[0] StatusDescriptions[1] Memory board has a configuration 3 (Degraded) 3 (Degraded) error, for example, there is a Degraded Memory board status: Configuration problem with the board release error latch (unlock error) or there is an improper configuration of memory modules on the board.
  • Page 337 Table 13-9 Class: SMX_MemoryModuleSlot Property name Property implementation Caption Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the memory slot is located...
  • Page 338: Smx_Memoryboardslot

    Table 13-9 Class: SMX_MemoryModuleSlot Property name Property implementation ElementName Memory Module Socket=y on MemoryBoard=x, where: x is the board/cartridge number where the memory slot is located y is the memory socket number where the memory slot is located Memory Module Socket=y on ProcessorBoard=x, where: x is the processor board/cartridge number where the memory slot is located...
  • Page 339 Table 13-10 Class: SMX_MemoryBoardSlot Property name Property implementation Caption Memory Board Slot MemoryBooard=x, where x is the board/cartridge number where the memory board is located. Memory Board Slot ProcessorBoard=x, where x is the processor board/cartridge number where the memory board is located. CIM_ManagedSystemElement OperationalStatus OperationalStatus[0] = 2 (OK)
  • Page 340: Smx_Memorymoduleinslot

    SMX_MemoryModuleInSlot 13-2-8 The class SMX_MemoryModuleInSlot represents the association between an SMX_MemoryModule and the SMX_MemoryModuleSlot where it resides. Table 13-11 Class: SMX_MemoryModuleInSlot Property name Property implementation CIM_ElementInConnector HP_ MemoryModuleInSlot SMX_MemoryModuleInSlot Antecedent ref: SMX_MemoryModuleSlot Dependent ref: SMX_MemoryModule SMX_MemoryBoardInSlot 13-2-9 The class SMX_MemoryBoardInSlot represents the association between an SMX_MemoryBoard and the SMX_MemoryBoardSlot where it resides.
  • Page 341: Smx_Memorymoduleslotlocation

    SMX_MemoryModuleSlotLocation 13-2-11 The class SMX_MemoryModuleSlotLocation extends the CIM_Location class and represents memory module slot locations on ProLiant Servers. There will be an instance of this class for each memory module slot in the system (whether the slot is occupied or not). Table 13-14 Class: SMX_ MemoryModuleSlotLocation Property name...
  • Page 342: Smx_Memoryboardslotlocation

    Table 13-14 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation Name HPQ:SMX_MemoryModuleSlotLocation:x-y, where: x is the board/cartridge number where the memory module slot is located y is the memory socket number where the memory module slot is located PhysicalPosition Opaque key. Example for memory socket number 2 on cpu/board/cartridge number 1: FF-FF-FF-FF-01-02-FF-79...
  • Page 343: Smx_Memorymoduleslotelementlocation

    Table 13-15 Class: SMX_ MemoryModuleSlotLocation Property name Property implementation Description Memory Board Slot Location MemoryBoard=x, where: x is the board/cartridge number where the memory board slot is located Memory Board Slot Location ProcessorBoard= x, where: x is the processor board/cartridge number where the memory board slot is located ElementName Memory Board Slot Location MemoryBoard=x, where:...
  • Page 344: Smx_Memoryboardslotelementlocation

    Table 13-16 Class: SMX_MemoryModuleSlotElementLocation Properties Property implementation CIM_ElementLocation HP_ElementLocation SMX_MemoryModuleSlotElementLocation Element ref: SMX_MemoryModuleSlot PhysicalLocation ref: SMX_MemoryModuleSlotLocation SMX_MemoryBoardSlotElementLocation 13-2-14 The class SMX_MemoryBoardSlotElementLocation extends the class CIM_ElementLocation and is used to associate a memory board slot (SMX_MemoryBoardSlot) with its corresponding location (SMX_MemoryBoardSlotLocation). There will be an instance of this class for each memory board slot in the system (whether the slot is occupied or not).
  • Page 345: Smx_Systemmemoryboard

    SMX_SystemMemoryBoard 13-2-16 The class SMX_SystemMemoryBoard represents an association between SMX_MemoryBoard and SMX_ComputerSystemChassis. There will be an instance of this class for each memory board slot in the chassis (whether the slot is occupied or not). Table 13-19 Class: SMX_SystemMemoryBoard Properties Property implementation CIM_Container HP_SystemMemoryBoard...
  • Page 346 Table 13-20 Class: SMX_MemoryRedundancySet Property name Property implementation OtherTypeOfSet OtherTypeOfSet[0] contains the type of redundancy when the property TypeOfSet[0] = 1 (Other). In this case, the property will contain the value Advanced ECC or Lockstep, otherwise the property is not populated. LoadBalanceAlgorithm 2 (No Load Balancing) RedundancyStatus...
  • Page 347: Smx_Memorycollection

    Table 13-20 Class: SMX_MemoryRedundancySet Property name Property implementation TargetConfiguration The desired or targeted mode of the Advanced Memory Protection system. TargetConfiguration is one of the following: • Advanced ECC, when the system is configured for Advanced ECC mode • RAID, when the system is configured for RAID (XOR) mode •...
  • Page 348: Smx_Hostedmemorycollection

    Table 13-21 Class: SMX_MemoryCollection Property name Property implementation GroupOperationalStatus Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the worst-of algorithm for physical memory boards...
  • Page 349: Smx_Memberofmemorycollection

    Table 13-23 Class: SMX_HostedMemoryCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_HostedMemoryCollection SMX_HostedMemoryCollection Antecedent ref: SMX_ComputerSystem Dependent ref: SMX_MemoryCollection SMX_MemberOfMemoryCollection 13-2-20 The class SMX_ MemberOfMemoryCollection represents an association between SMX_MemoryCollection and SMX_MemoryModule or SMX_MemoryBoard. Table 13-24 Class: SMX_MemberOfMemoryCollection Property name Property implementation CIM_MemberOfCollection HP_MemberOfMemoryCollection...
  • Page 350: Smx_Hostedmemoryredundancyset

    SMX_HostedMemoryRedundancySet 13-2-22 The class SMX_HostedMemoryRedundancySet represents an association between SMX_MemoryRedundancySet and the computer system that contains this redundancy set. Table 13-26 Class: SMX_HostedMemoryRedundancySet Property name Property implementation CIM_OwningCollectionElement HP_HostedMemoryRedundancySet SMX_HostedMemoryRedundancySet OwningElement ref: SMX_ComputerSystem OwnedElement ref: SMX_MemoryRedundancySet SMX_SystemMemoryModuleSlot 13-2-23 Note: This class is currently NOT implemented. The class SMX_SystemMemoryModuleSlot represents an association between SMX_MemoryModuleSlot and SMX_ComputerSystemChassis.
  • Page 351: Supported Indications

    Table 13-28 Class: SMX_SystemMemoryBoardSlot Properties Property implementation SMX_SystemMemoryBoardSlot GroupComponent ref: SMX_ComputerSystemChassis PartComponent ref: SMX_MemoryBoardSlot Supported indications 13-3 The following table describes the properties that are common to all of the SMX Memory Provider indications that are implemented for server platforms, where available: Table 13-29 Provider Indication Common Properties Property name...
  • Page 352 Table 13-29 Provider Indication Common Properties Property name Property implementation SystemGUID Platform GUID of the computer system generating the indication The following tables describe the SMX Memory Provider indications that are implemented for server platforms where available: Table 13-30 SMX_MemoryIndication: Memory Module Predictive Failure Property name Property implementation CIM_Indication...
  • Page 353 Table 13-31 SMX_MemoryIndication: Memory Board Error Property name Property implementation Description A memory board has an error. (MemoryBoardCaption) where MemoryBoardCaption is the SMX_MemoryBoard.Caption for the failing memory board. Table 13-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name Property implementation AlertingManagedElement WBEM Path of SMX_MemoryBoard instance representing the memory board AlertingElementFormat 2 (CIMObjectPath)
  • Page 354 Table 13-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name Property implementation RecommendedActions Check the Advanced Memory Protection configuration and replace the memor board and memory modules as necessary.” HP_AlertIndication Summary Advanced Memory Protection degraded EventCategory 3 (Memory) ProbableCause 88 (Loss of Redundancy) ProbableCauseDescription Advanced Memory Protection Degraded CIM_Indication...
  • Page 355: Smx_Bladeenclosurecs

    Blade System Lite Overview 14-1 The following profiles are implemented, and the following files are installed by this provider. Table 14-1 Overview Implemented Profiles • HP Blade System Lite Profile 2.0.3 Namespaces 14-2 This provider returns instances in the root/hpq namespace. Class implementations 14-3 The following classes reside in the local host OS CIMOM on each individual blade system and...
  • Page 356 Table 14-2 Class: SMX_BladeEnclosureCS Property name Property implementation OperationalStatus • 0 (Unknown), enclosure status: Unknown • 2 (OK), enclosure status: OK • 3 (Degraded), enclosure status: Degraded • 6 (Error), enclosure status: Error StatusDescriptions StatusDescriptions[0] per OperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown •...
  • Page 357: Smx_Bladeenclosurecollection

    Table 14-2 Class: SMX_BladeEnclosureCS Property name Property implementation ManagementIPAddress The enclosure’s management IP address ManagementURL The URL of the enclosure’s management web-based user interface ProductID The blade enclosure product name (model) string SerialNumber The blade enclusure serial number string RackName The name of the rack string RackUUID The UUID of the rack string...
  • Page 358: Smx_Bladesystemcomponent

    Table 14-3 Class: SMX_BladeEnclosureCollection Property name Property implementation GroupStatusDescriptions GroupStatusDescriptions[0] per GroupOperationalStatus[0]: • Server Blade Enclosure and Onboard Administrator status: Unknown • Server Blade Enclosure and Onboard Administrator status: OK • Server Blade Enclosure and Onboard Administrator status: Degraded • Server Blade Enclosure and Onboard Administrator status: Error HP_BladeEnclosureCollection...
  • Page 359: Smx_Bladeenclosuregrouphostedcollection

    SMX_BladeEnclosureGroupHostedCollection 14-3-5 SMX_BladeEnclosureGroupHostedCollection extends the class HP_GroupHostedCollection and associates the enclosure’s computer system instance to the blade enclosure collection instance. The following properties are implemented. Table 14-6 Class: SMX_BladeEnclosureGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_BladeEnclosureGroupHostedCollection Antecedent ref: HP_ComputerSystem Dependent ref: HP_BladeEnclosureCollection CIM_SoftwareIdentity...
  • Page 360: Cim_Elementsoftwareidentity

    VersionString String indicating the blade enclosure firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Server Blade Enclosure Firmware IdentityInfoValue An array in which first element contains the path of the...
  • Page 361: Smx_Bladecslocation

    Table 14-9 Class: SMX_BladeEnclosureInstalledFWIdentity Property name Property implementation CIM_InstalledSoftwareIdentity HP_BladeEnclosureInstalledFWIdentity System ref: HP_BladeEnclosureCS InstalledSoftware ref: HP_BladeEnclosureFW SMX_BladeCSLocation 14-3-9 SMX_BladeCSLocation is used to model the server blade location within an enclosure. Table 14-10 Class: SMX_BladeCSLocation Property name Property implementation CIM_ManagedElement Caption Blade Computer System Bay Location n, where n represents the blade bay slot position printed on the enclosure labeling...
  • Page 362: Supported Indications

    Table 14-11 Class: HP_ElementLocation Property name Property implementation Element References CIM_ComputerSystem PhysicalLocation References CIM_Location Supported indications 14-4 There are no indications specific to the blade system implementation. Blade System Lite 362...
  • Page 363: Smx_Fchbacomputersystem

    FC HBA Overview 15-1 This provider implements the HP FC HBA Profile which describes the behavior of Fibre Channel host adapters supporting the SCSI (FCP) command set. A Fibre Channel adapter used in a host system is called a Host Bus Adapter (HBA). An HBA is a physical device that contains one or more Fibre Channel ports.
  • Page 364: Smx_Fchbafcport

    Table 15-2 Class: SMX_FCHBAComputerSystem Property name Property implementation StatusDescriptions[0] • Unknown • • Stopped • Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_System CreationClassName SMX_FCHBAComputerSystem NameFormat Other CIM_ComputerSystem Dedicated IdentifyingDescriptions[0] HPQ:GUID OtherIdentifyingInfo[0] GUID SMX_FCHBAFCPort 15-3-2 SMX_FCHBAFCPort is used to represent a Fibre Channel port device.
  • Page 365 Table 15-3 Class: SMX_FCHBAFCPort Property name Property implementation StatusDescriptions[0] • Unknown • OK-Online • Stopped Offline • Stopped Bypassed • Stopped Diagnostics • Stopped Link down • Error CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreationClassName SMX_FCHBAFCPort...
  • Page 366: Smx_Fchbaportcontroller

    Table 15-3 Class: SMX_FCHBAFCPort Property name Property implementation UsageRestriction 4 (not restricted) CIM_NetworkPort LinkTechnology 4 (FC) PermanentAddress PortWWN PortNumber Port number SupportedMaximumTransmissionUnit Port maximum frame size SMX_FCHBAPortController 15-3-3 SMX_FCHBAPortController is a logical device corresponding to a hardware network port controller. Table 15-4 Class: SMX_FCHBAPortController Property name...
  • Page 367: Smx_Fchbalogicalportgroup

    SMX_FCHBAFCPortStatsitics represents statistics for a Fibre Channel port. In the following table HBAAPI_PORTSTATISTICS prefix refers to the HBA API HBA_PORTSTATISTICS structure. This information comes directly for the HBA and is not altered. Table 15-5 Class: SMX_FCHBAFCPortStatistics Property name Property implementation CIM_ManagedElement ElementName Product name...
  • Page 368: Smx_Fchbaphysicalpackage

    Table 15-6 Class: SMX_FCHBALogicalPortGroup Property name Property implementation Description Grouping of all FC Ports for this HBA Caption Logical Port Group ElementName Logical Port Group CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque CIM_LogicalPortGroup Name NodeWWN NameFormat SMX_FCHBAPhysicalPackage 15-3-6 SMX_FCHBAPhysicalPackage class represents the physical elements of the associated Fibre Channel port controller.
  • Page 369: Smx_Fchbaproduct

    Table 15-7 Class: SMX_FCHBAPhysicalPackage Property name Property implementation Version Board Version or N/A when not available CIM_PhysicalPackage RemovalConditions 2 (Not Applicable) SMX_FCHBAProduct 15-3-7 SMX_FCHBAProduct is used to aggregate physical element of the FC HBA. In the following table HBAAPI_ADAPTERATTRIBUTES prefix refers to the HBA API HBA_ADAPTERATTRIBUTES structure. This information comes directly for the HBA and is not altered.
  • Page 370: Smx_Fchbafirmwareidentityfw

    Table 15-9 Class: SMX_FCHBASoftwareIdentityDrv Property name Property implementation CIM_SoftwareIdentity ClassificationDescriptions FC HBA Driver Classifications 2 (Driver) InstanceID HPQ:NodeWWN:<instanceNum> where <instanceNum> is the port controller instance number for the same adapter Manufacturer Manufacturer VersionString File version of the Driver SMX_FCHBAFirmwareIdentityFW 15-3-9 SMX_FCHBA_FirmwareIdentityFW represents adapter firmware associated with the Fibre Channel port controller.
  • Page 371: Smx_Fchbagroupsystemspecificcollection

    SMX_FCHBAFirmwareIdentityBIOS represents adapter BIOS associated with the Fibre Channel port controller. Table 15-11 Class: SMX_FCHBA_FirmwareIdentityBIOS Property name Property implementation CIM_ManagedElement Caption FC HBA Option ROM Description FC HBA Option ROM detail for Model Name, where product name is the model name of the HBA. ElementName FC HBA Option ROM CIM_ManagedSystemElement...
  • Page 372: Smx_Fchbacomputersystemfcport

    Table 15-12 Class: SMX_FCHBAGroupSystemSpecificCollection Property name Property implementation ElementName FC HBA Consolidated Status CIM_Collection CIM_SystemSpecificCollection InstanceID Opaque HP_GroupSystemSpecificCollection GroupOperationalStatus[0] • 0 (Unknown) • 1 (Other) • 2 (OK) • 3 (Degraded) • 6 (Error) • 10 (Stopped) GroupStatusDescriptions[0] • Unknown •...
  • Page 373: Smx_Fchbacomputersystemlogicalportgroup

    Table 15-14 Class: SMX_FCHBAComputerSystemPortController Property name Property implementation CIM_Component CIM_SystemDevice SMX_FCHBAComputerSystemPortController GroupComponent ref:SMX_FCHBAComputerSystem PartComponent ref:SMX_FCHBAPortController SMX_FCHBAComputerSystemLogicalPortGroup 15-3-14 SMX_FCHBAComputerSystemLogicalPortGroup is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBALogicalPortGroup. Table 15-15 Class: SMX_FCHBAComputerSystemLogicalPortGroup Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection SMX_FCHBAComputerSystemLogicalPortGroup Antecedent ref:SMX_FCHBAComputerSystem Dependent...
  • Page 374: Smx_Fchbafcportlogicalportgroup

    SMX_FCHBAFCPortFCPortStatistics is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBAFCPortStatistics. Table 15-17 Class: SMX_FCHBAFCPortFCPortStatistics Property name Property implementation CIM_ElementStatisticalData SMX_FCHBAFCPortFCPortStatistics ManagedElement ref:SMX_FCHBAFCPort Stats ref:SMX_FCHBAFCPortStatistics SMX_FCHBAFCPortLogicalPortGroup 15-3-17 SMX_FCHBAFCPortLogicalPortGroup is used to represent an association between SMX_FCHBAFCPort and SMX_FCHBALogicalPortGroup. Table 15-18 Class: SMX_FCHBA_FCPortLogicalPortGroup Property name Property implementation...
  • Page 375: Smx_Fchbasoftwareidentitydrvportcontroller

    SMX_FCHBAPhysicalPackagePortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBA_PhysicalPackage. Table 15-20 Class: SMX_FCHBA_PhysicalPackagePortController Property name Property implementation CIM_Dependency CIM_Realizes SMX_FCHBA_PhysicalPackagePortController Antecedent ref:SMX_FCHBAPhysicalPackage Dependent ref:SMX_FCHBAPortController SMX_FCHBASoftwareIdentityDrvPortController 15-3-20 SMX_FCHBASoftwareIdentityDrvPortController is used to represent an association between SMX_FCHBAPortController and SMX_FCHBASoftwareIdentityDrv. Table 15-21 Class: SMX_FCHBASoftwareIdentityDrvPortController Property name Property implementation...
  • Page 376: Smx_Fchbaportcontrollerfirmwareidentitybios

    SMX_FCHBAPortControllerFirmwareIdentityBIOS 15-3-22 SMX_FCHBAPortControllerFirmwareIdentityBIOS is used to represent an association between SMX_FCHBAPortController and SMX_FCHBA_FirmwareIdentityBIOS. Table 15-23 Class: SMX_FCHBAPortControllerFirmwareIdentityBIOS Property name Property implementation CIM_Dependency CIM_ElementSoftwareIdentity SMX_FCHBAPortControllerFirmwareIdentityBIOS Antecedent ref:SMX_FCHBAFirmwareIdentityBIOS Dependent ref:SMX_HPFCHBAPortController SMX_FCHBAProductPhysicalComponent 15-3-23 SMX_FCHBAProductPhysicalComponent is used to represent an association between SMX_FCHBA_Product and SMX_FCHBAPhysicalPackage. Table 15-24 Class:SMX_FCHBAProductPhysicalComponent Property name...
  • Page 377: Smx_Fchbagrouphostedcollection

    Table 15-25 Class:SMX_FCHBASystemPackaging Property name Property implementation Dependent ref:SMX_ FCHBAComputerSystem SMX_FCHBAGroupHostedCollection 15-3-25 SMX_FCHBAGroupHostedCollection is used to represent an association between SMX_ComputerSystem and SMX_FCHBAGroupSystemSpecificCollection. Table 15-26 Class: SMX_FCHBAGroupHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection SMX_FCHBA_GroupHostedCollection Antecedent ref:SMX_ComputerSystem Dependent ref:SMX_FCHBAGroupSystemSpecificCollection SMX_FCHBAFCPortGroupSystemSpecific 15-3-26 SMX_FCHBAFCPortGroupSystemSpecific is used to represent an association between...
  • Page 378: Smx_Fchbaphysicalelementlocation

    Table 15-28 Class: SMX_FCHBALocation Property name Property implementation CIM_ManagedElement CIM_Location Name NodeWWN: SerialNumber:<instanceNum> Where <instanceNum> is the port controller instance number for the same adapter. HP_Location ElementLocationTag slot number ElementLocationTagDesc 1 (slot) PhysicalPosition Location—PCI Slot x where x is the PCI slot number or PCI Mezzanine=x where x is the Mezzanine slot number SMX_FCHBAPhysicalElementLocation...
  • Page 379: Smx_Fchbascsiprotocolendpoint

    Table 15-30 Class: SMX_FCHBASCSIProtocolController Property name Property implementation OperationalStatus[0] 0 (Unknown) 2 (OK-Online) 6 (Error) 10 (Stopped) 11 (In Service) CIM_LogicalElement CIM_EnabledLogicalElement EnabledDefault 2 (Enabled) EnabledState 5 (Not Applicable) RequestedState 12 (Not Applicable) CIM_LogicalDevice CreatingClassName SMX_FCHBASCSIProtocolController DeviceID PortWWN SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolController...
  • Page 380: Smx_Fchbacomputersystemscsiprotocolcontroller

    Table 15-31 Class: SMX_FCHBASCSIProtocolEndpoint Property name Property implementation SystemName Opaque value SystemCreationClassName SMX_FCHBAComputerSystem CIM_ProtocolEndpoint ProtocolFType 57 (HIPPI Interface) CIM_SCSIProtocolEndpoint ConnectionType 2 (fibre channel) Role 2 (initiator) SMX_FCHBAComputerSystemSCSIProtocolController 15-3-31 SMX_FCHBAComputerSystemSCSIProtocolController is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolController. Table 15-32 Class: SMX_FCHBAComputerSystemSCSIProtocolController Property name Property implementation...
  • Page 381: Smx_Fchbascsiprotocolcontrollerfcport

    SMX_FCHBASCSIProtocolControllerFCPort 15-3-33 SMX_FCHBASCSIProtocolControllerFCPort is used to represent an association between SMX_FCHBASCSIProtocolController and SMX_FCHBAFCPort Table 15-34 Class: SMX_FCHBAFCPortSCSIProtocolControllerFCPort Property name Property implementation CIM_Dependency CIM_ProtocolControllerForDevice CIM_ProtocolControllerFCPort SMX_FCHBASCSIProtocolControllerFCPort Antecendent ref:SMX_FCHBASCSIProtocolController Dependent ref:SMX_FCHBAFCPort SMX_FCHBASystemServiceAccessPoint 15-3-34 SMX_FCHBASystremServiceAccessPoint is used to represent an association between SMX_FCHBAComputerSystem and SMX_FCHBASCSIProtocolEndpoint. Table 15-35 Class: SMX_ FCHBASystremServiceAccessPoint Property name...
  • Page 382: Smx_Managementprocessor

    Management Processor Lite Overview 16-1 The profiles are implemented, and the following files are installed by this provider. Table 16-1 Overview Implemented Profiles • HP Management Processor (MP) Lite Profile 2.0.1 Namespaces 16-2 This provider returns instances in the root/hpq namespace. Class implementations 16-3 The following classes are implemented for HP server platforms where available.
  • Page 383 Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation Description Description of the Management Processor, including the product name. For example: HP Management Processor - <product name> where <product name> is the name of the MP product (same as the product name in property ElementName) Examples: “HP Management Processor –...
  • Page 384 Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation OperationalStatus Enumerators indicating the Management Processor operational status (refer to OperationalStatus mapping table in HP Management Processor (MP) Lite Profile for specific descriptions of when each value is populated). • OperationalStatus[0] contains MP operational status: ○...
  • Page 385 Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation HealthState • 0 (Unknown), when OperationalStatus[0]=0 (Unknown), or when software interface fails • 5 (OK), normal operation • 10 (Degraded/Warning), when OperationalStatus[0]=3 (Degraded) • 20 (Major failure), when OperationalStatus[0]=6 (Error) Note: When a Management processor is disabled (refer to property EnabledState) HealthState will always report a state of 5 (OK) so as not to contribute negatively to overall system status.
  • Page 386 Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation ControllerType Enumerator indicating the model or type of management processor (see the HPWmiMgmtProcLite.mof file). • 0 (Unknown) • 1 (Other) • 2 (PCI Board-Remote Insight Lights Out Edition II (RILOE II)) • 3 (Embedded Integrated Lights Out Controller (iLO)) •...
  • Page 387: Smx_Mpfirmware

    Table 16-2 Class: SMX_ManagementProcessor Property name Property implementation ActiveLicense The currently active iLO license type: • 0 (Unknown) • 1 (None) • 2 (iLO Advanced) • 3 (iLO Light) • 4 (iLO Advanced for BladeSystem) • 5 (iLO Standard for BladeSystem) LicenseKey Management Processor License Key HostName...
  • Page 388 VersionString String indicating the MP firmware version information. This property is the string translation of the content provided in the MajorVersion and MinorVersion properties. Manufacturer Hewlett-Packard Classifications 10 (Firmware) ClassificationDescriptions HP Management Processor Firmware IdentityInfoValue An array in which first element contains the path of the...
  • Page 389: Smx_Mpcollection

    SMX_MPCollection 16-3-3 SMX_MPCollection implements the class HP_MPCollection, and represents the collection of all management processor controller systems in a computer system, and forwards group operational status. The following properties are implemented. Table 16-4 Class: SMX_MPCollection Property name Property implementation CIM_ManagedElement Description HP Management Processor Collection ElementName...
  • Page 390: Smx_Mpcomponentcs

    Table 16-5 Class: SMX_MPHHostedCollection Property name Property implementation CIM_Dependency CIM_HostedDependency CIM_HostedCollection HP_GroupHostedCollection HP_MPHostedCollection Antecedent ref: HP_ComputerSystem Dependent ref: HP_MPCollection SMX_MPComponentCS 16-3-5 SMX_MPComponentCS implements the class HP_MPComponentCS, and associates a management processor subsystem to the scoping computer system that contains it. The following properties are implemented.
  • Page 391: Cim_Mpelementfirmwareidentity

    Table 16-7 Class: SMX_MPMemberOfCollection Property name Property implementation Included Writeable boolean property indicating if the management processor instance referenced by Member will contribute status to the HP_MPCollection. • TRUE—Include member status in collection status • FALSE—Do not include member status in collection status Collection ref: HP_MPCollection...
  • Page 392: Supported Indications

    Table 16-9 Class: SMX_MPInstalledFirmwareIdentity Property name Property implementation InstalledSoftware ref: HP_MPFirmware Supported indications 16-4 There are no indications specific to the management processor implementation. Management Processor Lite 392...
  • Page 393: Smx_Imlrecordlog

    IML Record Log Overview 17-1 This provider supports the Integrated management Log (IML) on ProLiant systems. The following table details the profiles implemented and files installed by this provider. Table 16-1 Overview Implemented Profiles HP Record Log Profile 1.0 Namespaces 17-2 The provider returns instances in the root/hpq namespace.
  • Page 394 Table 16-2 Class: SMX_IMLRecordLog Property name Property implementation OperationalStatus OperationStatus[0] indicates the highest severity of IML log entries and will contain one of the following: 2 (OK)— only informational or repaired events exist in the IML log; 3 (Degraded)— at least one degraded event exists in the IML log;...
  • Page 395: Smx_Imllogentry

    Table 176-3 Implemented Methods for SMX_IMLRecordLog Class Method Name Method Implementation ClearLog Refer to HP Record Log profile (P00109) RepairAll Refer to HP Record Log profile (P00109) SMX_IMLLogEntry 17-2-3 SMX_IMLLogEntry implements the class HP_CommonLogEntry to model logs records within the IML log.
  • Page 396: Smx_Imllogmanagesrecord

    Table 16-4 Class: SMX_IMLLogEntry Property name Property implementation Severity • 0 (Unknown) • 2 (Information) • 3 (Repaired) • 4 (Degraded/Warning) • 7 (Critical) OSType • 0 (Unknown) • 36 (Linux) • 39 (VMware) SystemSerialNumber System serial number string from SMBIOS SystemProductID System product ID string from SMBIOS SystemModel...
  • Page 397: Smx_Imluseoflog

    SMX_IMLUseOfLog 17-2-5 SMX_IMLUseOfLog implements theclass HP_UseOfLog and associates the instance of SMX_ComputerSystem with the instance of SMX_IMLRecordLog. The table below lists the properties implemented. Table 17-6 Class: SMX_IMLUseOfLog Property name Property implementation CIM_Dependency CIM_UseOfLog HP_UseOfLog Antecedent ref: SMX_IMLRecordLog Dependent ref: SMX_ComputerSystem Supported indications 17-3 There are no indications specific to the profile registration implementation.

Table of Contents