Warm_Boot_Server; Warm_Boot_Server Parameters; Warm_Boot_Server Runtime Errors; Get_Uid_Status - HP Integrated Lights-Out User Manual

Hp integrated lights-out user guide
Hide thumbs Also See for HP Integrated Lights-Out:
Table of Contents

Advertisement

WARM_BOOT_SERVER

This WARM_BOOT_SERVER command is used to warm boot a server. For this
command to parse correctly, the WARM_BOOT_SERVER command must
appear within a SERVER_INFO command block, and SERVER_INFO MODE
must be set to write. The user must have the virtual power and reset privilege to
execute this command.
Example:

WARM_BOOT_SERVER Parameters

There are no parameters for this command.

WARM_BOOT_SERVER Runtime Errors

The possible error messages include:

GET_UID_STATUS

The UID_STATUS command requests the state of the server UID. For this
command to parse correctly, the UID_STATUS command must appear within a
SERVER_INFO command block, and SEVER_INFO MODE can be set to read
or write.
<RIBCL VERSION="2.0">
<LOGIN USER_LOGIN="adminname" PASSWORD="password">
<SERVER_INFO MODE="write">
<WARM_BOOT_SERVER/>
</SERVER_INFO>
</LOGIN>
</RIBCL>
Server information is open for read-only access. Write access is required for
this operation.
Host power is already OFF.
User does not have correct privilege for action. RESET_SERVER_PRIV
required.
Remote Insight Command Language
323

Advertisement

Table of Contents
loading