Auxiliary connector outputs (MCC1 and
Media Gateways only)
Connect a 25-pair cable from the AUX connector on the back of the expansion control carrier to a
connecting block on the trunk/auxiliary field.
Table 18, Auxiliary lead appearances at AUX connector,
•
control carrier outputs cable pinouts
•
pinouts for an external alarm
•
port circuit pack and telephone pin designations
The control carrier AUX connector outputs include:
•
Two inputs for external alarm signals
•
Seven -48 VDC power sources for emergency transfer units
•
Three -48 VDC power sources for remotely powering three attendant consoles or telephone
adjuncts
•
A relay contact that actuates a customer-supplied light, bell, or similar device. The relay can
activate when a major, minor, or warning condition occurs. The device connected to the alarm
leads must not exceed a rating of 30 VAC rms or 60 VDC at 0.75 amperes.
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
December 2003
Installing and wiring telephones and trunks
on page 204 shows the:
203