Avaya S8700 Installation Instructions Manual page 169

Installing an avaya s8700 media server with an avaya g650 media gateway
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

Figure 66: Model 507B sneak fuse panel
Figure notes
1
507B sneak current protector
2
25-pair male connector (in)
Table 12: Sneak fuse panel ordering information
Description
157B Connecting Block
SCP-110 Protector
507B Sneak Current Fuse Panel
220029 Sneak Current Fuse
25-pair male connector
25-pair female connector
Connector cables (B25A male to female) connect the network interface to the sneak fuse panel. Also,
157B connecting blocks equipped with SCP-110 protectors can be used for sneak current protection.
The 507B includes 52 sneak fuses and two cables and can be ordered using PEC code 63210. Use the
SCP-110 protectors with 110-type hardware and on the 507B sneak fuse panel. The SCP-110 Protectors
can be ordered separately and installed on the 157B connecting block. Fifty protectors are required per
block.
Install the 507B near the network interface or patch panels with locally obtained #12 x 3/4-inch screws
(or equivalent).
Installing the Avaya S8700 Media Server with an Avaya G650 Media Gateway
December 2003
Sneak
Current
Protector
507B
3
25-pair female connector (out)
4
220029 fuses (inside panel). Use a small
screwdriver to pry top cover off
Comcode
403613003
406948976
107435091
407216316
846300994
846300994
169

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

G650

Table of Contents