Display Transceiver Diagnosis - HP 6125XLG Command Reference Manual

Blade switch fundamentals command reference
Table of Contents

Advertisement

Field
Transceiver type not supported by port hardware
QSFP+:
RX signal loss in channel x
TX fault in channel x
TX signal loss in channel x
RX power high in channel x
RX power low in channel x
TX bias high in channel x
TX bias low in channel x
Temp high
Temp low
Voltage high
Voltage low
Transceiver info I/O error
Transceiver info checksum error
Transceiver type and port configuration
mismatch
Transceiver type not supported by port hardware
Examples
# Display the alarms present on the transceiver module in interface Ten-GigabitEthernet 1/1/5.
<Sysname> display transceiver alarm interface ten-gigabitethernet 1/1/5
Ten-GigabitEthernet1/1/5 transceiver current alarm information:
RX loss of signal
RX power low
Table 25 Command output
Field
transceiver current alarm information
RX loss of signal
RX power low

display transceiver diagnosis

Use display transceiver diagnosis to display the current measured values of the digital diagnosis
parameters for transceiver modules.
Syntax
display transceiver diagnosis interface [ interface-type interface-number ]
Remarks
The port does not support this type of transceiver modules.
Received signals are lost in channel x.
Transmission error in channel x.
The transmitted signal in channel x is lost.
The received optical power is high in channel x.
The received optical power is low in channel x.
The transmitted bias current is low.
The transmitted bias current is high.
The temperature is high.
The temperature is low.
The voltage is high.
The voltage is low.
Transceiver information read/write error.
Transceiver information checksum error.
The type of the transceiver module does not match the port
configuration.
The port does not support this type of transceiver modules.
Description
Alarms present on the transceiver module.
Received signals are lost.
Received power is low.
163

Advertisement

Table of Contents
loading

Table of Contents