Display Transceiver Alarm - HP 6125XLG Command Reference Manual

Blade switch fundamentals command reference
Table of Contents

Advertisement

The current system working mode is standard.
The next system working mode is advance.

display transceiver alarm

Use display transceiver alarm to display the alarms present on transceiver modules.
Syntax
display transceiver alarm interface [ interface-type interface-number ]
Views
Any view
Predefined user roles
network-admin
network-operator
Parameters
interface [ interface-type interface-number ]: Specifies an interface by its type and number. If no interface
is specified, this command displays the alarms present on the transceiver modules on all interfaces.
Usage guidelines
Table 24
shows the alarms that might occur to the commonly used transceiver modules.
If no error occurs, "None" is displayed.
Table 24 Alarms on commonly used transceiver modules
Field
SFP /SFP+:
RX loss of signal
RX power high
RX power low
TX fault
TX bias high
TX bias low
TX power high
TX power low
Temp high
Temp low
Voltage high
Voltage low
Transceiver info I/O error
Transceiver info checksum error
Transceiver type and port configuration
mismatch
Remarks
Received signals are lost.
The received optical power is high.
The received optical power is low.
Transmission error.
The transmitted bias current is high.
The transmitted bias current is low.
The transmitted optical power is high.
The transmitted optical power is low.
The temperature is high.
The temperature is low.
The voltage is high.
The voltage is low.
Transceiver information read/write error.
Transceiver information checksum error.
The type of the transceiver module does not match the port
configuration.