Displaying Vlan Information; Displaying Vlans In Alphanumeric Order - Dell PowerConnect B-FCXs Configuration Manual

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

13

Displaying VLAN information

The show vlan command displays a separate row for dual-mode ports on each VLAN.
Example
PowerConnect# show vlan
Total PORT-VLAN entries: 3
Maximum PORT-VLAN entries: 16
legend: [S=Slot]
PORT-VLAN 1, Name DEFAULT-VLAN, Priority level0, Spanning tree Off
Untagged Ports: (S1)
Untagged Ports: (S2)
Untagged Ports: (S2) 20 21 22 23 24
DualMode Ports: None
PORT-VLAN 10, Name [None], Priority level0, Spanning tree Off
Untagged Ports: (S2) 10
DualMode Ports: (S2) 11
PORT-VLAN 20, Name [None], Priority level0, Spanning tree Off
Untagged Ports: None
DualMode Ports: (S2) 11
Displaying VLAN information
After you configure the VLANs, you can verify the configuration using the show commands
described in this section.
NOTE
If a VLAN name begins with "GVRP_VLAN_", the VLAN was created by the GARP VLAN Registration
Protocol (GVRP). If a VLAN name begins with "STATIC_VLAN_", the VLAN was created by GVRP and
then was converted into a statically configured VLAN.

Displaying VLANs in alphanumeric order

By default, VLANs are displayed in alphanumeric order, as shown in the following example.
PowerConnect# show run
...
vlan 2 by port
...
vlan 10 by port
...
vlan 100 by port
...
500
1
1
Tagged Ports: None
Uplink Ports: None
Tagged Ports: None
Uplink Ports: None
Tagged Ports: (S2)
9
Uplink Ports: None
2
3
4
5
6
7
8
2
3
4
5
6
7
8 12 13 14 15 16 17 18 19
PowerConnect B-Series FCX Configuration Guide
53-1002266-01

Advertisement

Table of Contents
loading