Dell PowerConnect B-FCXs Configuration Manual page 842

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

26
Configuring IP parameters – Layer 3 Switches
By default, you can configure up to 24 IP addresses on each interface.
You can increase this amount to up to 128 IP subnet addresses per port by increasing the size of
the ip-subnet-port table.
Refer to the section
NOTE
Once you configure a virtual routing interface on a VLAN, you cannot configure Layer 3 interface
parameters on individual ports. Instead, you must configure the parameters on the virtual routing
interface itself.
Dell PowerConnect devices support both classical IP network masks (Class A, B, and C subnet
masks, and so on) and Classless Interdomain Routing (CIDR) network prefix masks:
By default, the CLI displays network masks in classical IP address format (example:
255.255.255.0). You can change the display to prefix format. Refer to
display to prefix format"
Assigning an IP address to an Ethernet port
To assign an IP address to port 1/1, enter the following commands.
PowerConnect(config)# interface ethernet 1/1
PowerConnect(config-if-1/1)# ip address 192.45.6.1 255.255.255.0
You also can enter the IP address and mask in CIDR format, as follows.
PowerConnect(config-if-1/1)# ip address 192.45.6.1/24
Syntax: [no] ip address <ip-addr> <ip-mask> [ospf-ignore | ospf-passive | secondary]
or
Syntax: [no] ip address <ip-addr>/<mask-bits> [ospf-ignore | ospf-passive | secondary]
The ospf-ignore | ospf-passive parameters modify the Layer 3 Switch defaults for adjacency
formation and interface advertisement. Use one of these parameters if you are configuring multiple
IP subnet addresses on the interface but you want to prevent OSPF from running on some of the
subnets:
800
Virtual routing interface (also called a Virtual Ethernet or "VE")
Loopback interface
"Displaying and modifying system parameter default settings"
To enter a classical network mask, enter the mask in IP address format. For example, enter
"209.157.22.99 255.255.255.0" for an IP address with a Class-C subnet mask.
To enter a prefix network mask, enter a forward slash ( / ) and the number of bits in the mask
immediately after the IP address. For example, enter "209.157.22.99/24" for an IP address
that has a network mask with 24 significant bits (ones).
on page 869.
ospf-passive – This option disables adjacency formation with OSPF neighbors. By default,
when OSPF is enabled on an interface, the software forms OSPF router adjacencies between
each primary IP address on the interface and the OSPF neighbor attached to the interface.
ospf-ignore – This option disables OSPF adjacency formation and also disables advertisement
of the interface into OSPF. The subnet is completely ignored by OSPF.
"Changing the network mask
PowerConnect B-Series FCX Configuration Guide
on page 321.
53-1002266-01

Advertisement

Table of Contents
loading

Table of Contents