Dell PowerConnect B-FCXs Configuration Manual page 706

Powerconnect b-series fcx
Hide thumbs Also See for PowerConnect B-FCXs:
Table of Contents

Advertisement

22
Displaying IGMP snooping information
PowerConnect# show ip multicast group 224.1.1.1 tracking
Display group 224.1.1.1 in all interfaces with tracking enabled.
p-:physical, ST:static, QR:querier, EX:exclude, IN:include, Y:yes, N:no
VL70 : 1 groups, 1 group-port, tracking_enabled
*** Note: has 1 static groups to the entire vlan, not displayed here
1
Syntax: show ip multicast group [<group-address> [detail] [tracking]]
If you want a report for a specific multicast group, enter that group's address for <group-address>.
Enter detail to display the source list of a specific VLAN.
Enter tracking for information on interfaces that have tracking enabled.
The following table describes the information displayed by the show ip multicast group command.
Field
group
p-port
ST
QR
life
mode
source
Displaying IGMP snooping mcache information
The IGMP snooping mcache contains multicast forwarding information for VLANs. To display
information in the multicast forwarding mcache, enter the following command.
PowerConnect# show ip multicast mcache
Example: (S G) cnt=: cnt: SW proc. count
vlan 1, 1 caches. use 1 VIDX
1
vlan 70, 1 caches. use 1 VIDX
1
664
group
p-port
224.1.1.1
0/1/33
receive reports from 1 clients: (age)
(2.2.100.2 60)
Description
The address of the group (destination address in this case, 224.1.1.1)
The physical port on which the group membership was received.
Yes indicates that the IGMP group was configured as a static group; No means the address
was learned from reports.
Yes means the port is a querier port; No means it is not. A port becomes a non-querier port
when it receives a query from a source with a lower source IP address than the device.
The number of seconds the group can remain in EXCLUDE mode. An EXCLUDE mode changes
to INCLUDE mode if it does not receive an "IS_EX" or "TO_EX" message during a certain period
of time. The default is 140 seconds. There is no life displayed in INCLUDE mode.
Indicates current mode of the interface: INCLUDE or EXCLUDE. If the interface is in INCLUDE
mode, it admits traffic only from the source list. If an interface is in EXCLUDE mode, it denies
traffic from the source list and accepts the rest.
Identifies the source list that will be included or excluded on the interface.
For example, if an IGMPv2 group is in EXCLUDE mode with a source of 0, the group excludes
traffic from the 0 (zero) source list, which actually means that all traffic sources are included.
OIF: 0/1/22 TR(0/1/32,0/1/33), TR is trunk, 0/1/32 primary, 0/1/33 output
(1.2.10.102 225.1.1.1) cnt=46
OIF: 0/1/4
age=0m up-time=45m vidx=4130 (ref-cnt=1)
(* 226.1.2.3) cnt=69
OIF: 0/1/14
age=0m up-time=59m vidx=4129 (ref-cnt=1)
ST
QR
life mode
no
yes
100
EX
PowerConnect B-Series FCX Configuration Guide
source
0
53-1002266-01

Advertisement

Table of Contents
loading