Syntax: show optic <port-number>
NOTE
The show optic function takes advantage of information stored and supplied by the manufacturer of
the XFP or SFP transceiver. This information is an optional feature of the Multi-Source Agreement
standard defining the optical interface. Not all component suppliers have implemented this feature
set. In such cases where the XFP or SFP transceiver does not supply the information, a "Not
Available" message will be displayed for the specific port on which the module is installed.
The following table describes the information displayed by the show optic command.
TABLE 43
This field...
Port
Temperature
Tx Power
Rx Power
Tx Bias Current
For Temperature, Tx Power, Rx Power, and Tx Bias Current in the show optic command output,
values are displayed along with one of the following alarm status values: Low-Alarm, Low-Warn,
Normal, High-Warn or High-Alarm. The thresholds that determine these status values are set by the
manufacturer of the optical transceivers.
TABLE 44
Status value
Low-Alarm
Low-Warn
Normal
High-Warn
High-Alarm
PowerConnect B-Series FCX Configuration Guide
53-1002266-01
Normal
Normal
Output from the show optic command
Alarm status value description
Description
Monitored level has dropped below the "low-alarm" threshold set by the manufacturer of the
optical transceiver.
Monitored level has dropped below the "low-warn" threshold set by the manufacturer of the
optical transceiver.
Monitored level is within the "normal" range set by the manufacturer of the optical transceiver.
Monitored level has climbed above the "high-warn" threshold set by the manufacturer of the
optical transceiver.
Monitored level has climbed above the "high-alarm" threshold set by the manufacturer of the
optical transceiver.
Digital optical monitoring
Normal
Normal
Displays...
The Dell port number.
The operating temperature, in degrees Celsius, of the optical
transceiver.
The alarm status, as described in
The transmit power signal, in decibels (dB), of the measured power
referenced to one milliwatt (mW).
The alarm status, as described in
The receive power signal, in decibels (dB), of the measured power
referenced to one milliwatt (mW).
The alarm status, as described in
The transmit bias power signal, in milliamperes (mA).
The alarm status, as described in
Table 44
describes each of these status values.
6
Table
44.
Table
44.
Table 44
Table
44.
195