Getting Started with the TN2501AP or G700 Virtual VAL

Before you can use the capabilities of the TN2501AP or G700 VVAL announcement circuit
pack, it must be properly installed and configured. These instructions are contained in other
documents in the Avaya Communication Manager documentation library. For more information
about these and other tasks related to using the TN2501AP, see the documents listed in the
following table.
.
Task
Installing the TN2501AP
Administering IP Connections
Adding IP Routes
Testing the IP Connections
Installing VVAL for a G700 Media
Gateway using the Media-Gateway
screen and the enable announcement
command
Administering IP Connections
Adding IP Routes
Testing the IP Connections
Note: G700 Media Gateway embedded
VAL announcements (VVAL) must have
the gateway(s) that will provide
announcements enabled in order for
announcement extensions assigned to
that gateway to be played.
Getting Started with the TN2501AP or G700 Virtual VAL
Information source
Made Easy Tool for DEFINITY Media Server
Configurations
Installation, Upgrades and Additions for the
Avaya CMC1 Media Gateway
Each G700 Media Gateway that will be used to
provide announcements through the
embedded VAL circuitry on the Gateway
processor circuit pack must be assigned on the
Media-Gateway
screen and enabled using the
enable announcements command before
announcements can be recorded using the
telephone or played from that gateway.
Announcements can be administered to a
gateway and files can be FTPed to that
gateway even though it is not enabled.
However, the G700 Media Gateway first must
be assigned on the Media-Gateway screen so
as to be used for gateway announcements.
Each G700 Media Gateway when enabled is
counted as a VAL circuit pack towards the
system limit of either 1 VAL circuit pack (if the
VAL Maximum Capacity field is n) or 10
circuit packs (for the S8700 series, or S8300
Media Servers) if the VAL Maximum Capacity
field is y.
First the G700 Media Gateway must have the
V9 field assigned to
gateway-announcements on the
Media-Gateway screen before the G700
embedded VAL (VVAL) can be enabled.
Then the G700 Media Gateway embedded
VAL is enabled using the enable
announcement-board ggV9 command
(where gg is the gateway number assigned on
the Media-Gateway screen).