Direct Station Selector (DSS) Page Buttons

Direct Station Selector (DSS) Page
Buttons
Use this procedure to set the three Page buttons on the DSS to correspond to
the system numbering plan. This procedure assigns extension numbers to
DSS buttons. You cannot program individual buttons on a DSS; this is the only
method for programming DSS buttons.
Page button assignment should be sequential. If only one DSS is attached,
each Page button assignment sets the console for a range of 50 extension
numbers: Page 1: 0 to 49; Page 2: 50 to 99; Page 3: 100 to 149.
If two DSSs are attached, each Page button assignment sets the console for a
range of 100 extension numbers. If two DSSs are attached to the console,
change the factory setting so that the difference between extension numbers
assigned to the range is at least 100. For example, assign Page 1 to begin
with extension 10, Page 2 to begin with extension 110, and Page 3 to begin
with extension 210.
Operator Park Zone codes must be included in the extension number range
specified for one of the Page buttons.
CAUTION:
Select Exit on the console or [F5] on the PC when you have finished this
procedure. If you press Home, extensions may remain in the forced idle
condition (the LED next to each DSS button is on), and the system may
have to be restarted.
3-8 System Renumbering