AT&T MERLIN LEGEND Release 3.0 Programming Summary Manual page 136

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 3.0:
Table of Contents

Advertisement

Timers and Counters
Table 9-1. Timers and Counters
Timer/Counter
T200 Timer
T203 Timer
N200 Counter
N201 Counter
K Counter
T303 Timer
T305 Timer
T308 Timer
T309 Timer
T310 Timer
T313 Timer
T316 Timer
9-14 PRI Facilities
Purpose
Maximum response time
Maximum time
Maximum transmissions
Maximum octets
Maximum outstanding
I-frames
Set up timeout
Disconnect timeout
Release timeout
Signal loss
Call Proc. timeout
Connect timeout
Restart timeout
Factory Setting
1 second
30 seconds
3 transmissions
260 octets
7 frames
4 seconds
4 seconds
4 seconds
90 seconds
10 seconds
4 seconds
120 seconds
Valid Range
1000 to 3000 ms
1 to 60 seconds
1 to 5
transmissions
16 to 260 octets
1 to 15 frames
4 to 12 seconds
4 to 30 seconds
4 to 12 seconds
30 to 120 seconds
2 to 10 seconds
4 to 12 seconds
30 to 120 seconds

Advertisement

Table of Contents
loading