Fluke 5500A Operator's Manual page 366

Multi-product calibrator
Hide thumbs Also See for 5500A:
Table of Contents

Advertisement

5500A
Operator Manual
Leveled Sinewave Function Verification: Flatness (cont.)
Nominal Value (p-p)
100.0 mV
100.0 mV
100.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
400.0 mV
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
1.3 V
8-94
Frequency
Measured Value (p-p)
220 MHz
235 MHz
250 MHz
500 kHz
1 MHz
1 MHz
2 MHz
5 MHz
10 MHz
20 MHz
50 MHz
100 MHz
125 MHz
160 MHz
200 MHz
220 MHz
235 MHz
250 MHz
500 kHz
1 MHz
1 MHz
2 MHz
5 MHz
10 MHz
20 MHz
50 MHz
100 MHz
125 MHz
160 MHz
200 MHz
220 MHz
235 MHz
Deviation (mV)
1-Year Spec. (mV)
2.10
2.10
2.10
6.10
6.10
6.10
6.10
6.10
6.10
6.10
6.10
6.10
8.10
8.10
8.10
8.10
8.10
8.10
19.60
19.60
19.60
19.60
19.60
19.60
19.60
19.60
19.60
26.10
26.10
26.10
26.10
26.10