Version Improvements

1-4-10 Version 5.0

Item
Support for LCB01/05 and
supports for Loop-control CPU
Units (CJ1G-CPUVVP) Ver. 3.0
Free positioning of block
diagrams
Increase in the number of blocks
that can be registered in function
block groups
Transferring tag comment data to
flash memory
Wireless debugging
User link
MV tight shut
tables
ab es
function
MV analog output
reversal function
Copying/pasting
EM bank
specification
Pulse output
Table reference function for
sequence tables
Step ladder timer instructions
The improvements made from version 4.1 to version 5.0 of the CX-Process Tool
are listed in the following table.
Ver. 4.1
Only Ver. 2.0 or earlier
were supported.
Not supported
(positioning was
possible only at fixed
locations)
Only 16 blocks could be
registered in each
function block group.
Not supported. (Transfer
was possible to a
Memory Card in the
CPU Unit.)
Not supported.
Not supported.
Not supported.
Not supported.
Not supported. (Only the
current bank could be
used.)
Not supported.
Not supported.
Not supported.
Note These functions are supported only for Loop Control Boards and Loop-control
CPU Units with unit version 3.0 or later.
Ver. 5.0 (See note.)
The following functions are supported for LCB01/05 and
supports for Loop-control CPU Units (CJ1G-CPUVVP)
Ver. 3.0:
• Switch Instrument (Block Model 225), AI 2-point Termi-
nal (Block Model 571), and AI 16-point Terminal (Block
Model 582)
• Switching the adjustment operation direction for Basic
PID (Block Model 011) and Advanced PID (Block Model
012)
• Switching RUN/STOP for Basic PID (Block Model 011)
and Advanced PID (Block Model 012)
• Tight shunt function and analog output reversal function
for analog output terminals.
Positioning is possible anywhere in the block diagram.
Up to 64 blocks can be registered in each function block
group.
The following data can be transferred to flash memory in
the Loop Controller: block diagram data, tags,
comments, annotations, etc. (Data cannot be transferred
to a Memory Card for Loop Control Board version 3.0.)
A fixed value can be input as a pseudo-input to
adjustment block PVs in a new calibration mode.
Tight shut outputs to I/O memory in the CPU Unit are
supported.
Reversing outputs to I/O memory in the CPU Unit are
supported.
Entries in user link tables can be copied and pasted.
EM0 to EMC can be specified.
Pulse output writing (ON for one refresh cycle) is
possible to I/O memory in the CPU Unit when a
specified ITEM turns ON.
Results of conditions set in other tables can be
referenced from Sequence Table (Block Model 302)
suing TBL commands.
Timer commands (TIM) can be used in Step Ladder
Program (Block Model 301)
Section
1-4
23