Omron CJ - 09-2009 Operation Manual page 675

Programmable controllers
Table of Contents

Advertisement

Auxiliary Area
Addresses
Name
Word
Bit
A597
---
DR00 Out-
put for Back-
ground
Execution
A598
A59800
FPD Teach-
ing Bit
A59801
Equals Flag
for Back-
ground Exe-
cution
A600 to
Macro Area
A603
Input Words
A604 to
Macro Area
A607
Output
Words
A619
A61901
Peripheral
Port Set-
tings Chang-
ing Flag
A61902
RS-232C
Port Set-
tings Chang-
ing Flag
A620
A62001
Communica-
tions Unit 0,
Port 1 Set-
tings Chang-
ing Flag
A62002
Communica-
tions Unit 0,
Port 2 Set-
tings Chang-
ing Flag
A62003
Communica-
tions Unit 0,
Port 3 Set-
tings Chang-
ing Flag
A62004
Communica-
tions Unit 0,
Port 4 Set-
tings Chang-
ing Flag
Function
When a data register is specified as
the output for an instruction pro-
cessed in the background, A597
receives the output instead of DR00.
Turn this bit ON to set the monitoring
time automatically with the teaching
function.
While A59800 is ON, FPD(269) mea-
sures how long it takes for the diag-
nostic output to go ON after the
execution condition goes ON. If the
measured time exceeds the monitor-
ing time, the measured time is multi-
plied by 1.5 and that value is stored
as the new monitoring time.
(The teaching function can be used
only when a word address has been
specified for the monitoring time
operand.)
Turns ON if matching data is found
for an SRCH(181) instruction exe-
cuted in the background.
When MCRO(099) is executed, the
contents of the four specified source
words (starting from the 1st input
parameter word) are copied here.
The contents of the four copied
words are then passed to the sub-
routine.
After the subroutine specified in
MCRO(099) has been executed, the
results of the subroutine are trans-
ferred from A604 through A607 to
the specified destination words. (out-
put parameter words)
ON while the peripheral port's com-
munications settings are being
changed. This flag will be turned ON
when STUP(237) is executed and it
will be turned OFF after the settings
have been changed.
ON while the RS-232C port's com-
munications settings are being
changed. This flag will be turned ON
when STUP(237) is executed and it
will be turned OFF after the settings
have been changed.
The corresponding flag will be ON
when the settings for that port are
being changed.
The flag will be turned ON when
STUP(237) is executed and it will be
turned OFF by an event issued from
the Serial Communications Unit after
the settings have been changed.
It is also possible for the user to indi-
cate a change in serial port settings
by turning these flags ON.
Settings
Status
Status at
after
startup
mode
change
0000 to FFFF
Cleared
Cleared
hex
1: Teach moni-
Cleared
Cleared
toring time
0: Teaching
function off
1: Search data
Cleared
Cleared
found in table
0: Search data
not found
Input data:
Cleared
Cleared
4 words
Output data:
Cleared
Cleared
4 words
1: Changing
Retained Cleared
0: Not chang-
ing
1: Changing
Retained Cleared
0: Not chang-
ing
1: Changing
Retained Cleared
0: Not chang-
ing
1: Changing
Retained Cleared
0: Not chang-
ing
1: Changing
Retained Cleared
0: Not chang-
ing
1: Changing
Retained Cleared
0: Not chang-
ing
Appendix C
Write timing/
Related Flags,
Settings
Not supported by
CJ1@-CPU@@ CPU
Units
---
Not supported by
CJ1@-CPU@@ CPU
Units
---
---
---
---
---
---
---
---
627