Examples
218
2. Make the required settings.
3. After completing the settings, transfer the PLC Setup to the PLC.
Making the Settings with the Programming Console
When a Programming Console is used to set the PLC Setup, the PLC Setup
settings are arranged by word addresses. Refer to the provided Programming
Console settings sheet for details.
Setting with a Programming Console
In this example, the Programming Console is used to set the Watch Cycle
Time (maximum cycle time) in 10-ms units.
The following diagram shows the required Programming Console operations.
Address
Bits
209
15
0 to 14
FUN
Specifying a word address in the PLC Setup.
(Example: 209)
2
0
Setting
Enable for Watch Cycle Time
setting
Watch Cycle Time setting
000000 CT00
CLR
PC SETUP
VRFY
0:MODE1:PC SETUP
PC SETUP
1
+000 0000
PC SETUP
9
+209
Section 4-2
Setting range
0: Use default
1: Use setting in
bits 0 to 14.
0001 to 0FA0