Specifications of Basic I/O Units
CJ1W-MD563 TTL I/O Unit (MIL Connector, 32 Inputs/32 Outputs)
Output section (CN1)
Rated Voltage
5 V DC±10%
Operating Load Volt-
4.5 to 5.5 V DC
age Range
Maximum Load Cur-
35 mA/point, 560 mA/common,
rent
1.12 A/Unit
Leakage Current
0.1 mA max.
Residual Voltage
0.4 V max.
ON Response Time
0.2 ms max.
OFF Response Time 0.3 ms max.
No. of Circuits
32 points (16 points/common, 2 cir-
cuits)
Fuse
None
5 V DC±10%, 40 mA min. (1.2 mA ×
External Power Sup-
ply
No. of ON points)
Insulation Resistance 20 MΩ between the external terminals and the GR terminal (at 100 V DC)
Dielectric Strength
1,000 V AC between the external terminals and the GR terminal for 1 minute at a leakage current
of 10 mA max.
Internal Current Con-
5 V DC 190 mA max.
sumption
Weight
110 g max.
Accessories
None
Note The ON response time will be 120 µs maximum and OFF response time will be 400 µs maximum even if
the response times are set to 0 ms due to internal element delays.
Circuit Configuration
CN1 (OUT)
Output indicator
+V
5.6 k Ω
OUT00
OUT15
COM0
COM0
Indicator switch
+V
5.6 k Ω
OUT00
OUT15
COM1
COM1
Input section (CN2)
Rated Input Voltage
Input Impedance
Input Current
ON Voltage
OFF Voltage
ON Response Time
OFF Response Time 8.0 ms max. (Can be set to between
No. of Circuits
Number of Simulta-
neously ON Points
CN2 (IN)
1.1 kΩ
IN00
to
IN15
to
COM2
COM2
1.1 kΩ
IN00
to
IN15
to
COM3
COM3
Appendix A
5 V DC±10%
1.1 kΩ
Approx. 3.5 mA (at 5 V DC)
3.0 V DC min.
1.0 V DC max.
8.0 ms max. (Can be set to between
0 and 32 in the PLC Setup.) (See
note.)
0 and 32 in the PLC Setup.) (See
note.)
32 points (16 points/common, 2 cir-
cuits)
100% (16 points/common)
Indicator switch
Input indicator
563