3. If the error recurs, replace the DIMMs.
• Diagnostic Code:
196F01D3
Full Sensor Name (Sensor Name In SDR):
PCH_Therm_Trip
Sensor Type:
Chipset
Event Severity:
Critical
Description:
Thermal Trip - Asserted
Message:
PCH temperature is too high. At the same time, system will be shutdown.
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, contact Lenovo service representative for execution of node replacement.
• Diagnostic Code:
0D6F01D4
Full Sensor Name (Sensor Name In SDR):
HDD_Status
Sensor Type:
Drive Slot (Bay)
Event Severity:
Critical
Description:
Drive Fault - Asserted
Message:
HDD fault.
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Replace the hard disk drive.
3. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
1D6F02E0
Full Sensor Name (Sensor Name In SDR):
BIOS_Boot_up
Sensor Type:
System Boot / Restart Initiated
Appendix A. TMM error messages
201