• Diagnostic Code:
01010729
Full Sensor Name (Sensor Name In SDR):
PCH_Temp
Sensor Type:
Temperature
Event Severity:
Warning
Description:
Upper Non-Critical - Going High - Asserted
Message:
PCH temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, contact Lenovo service representative for execution of node replacement.
• Diagnostic Code:
01010B2A
01010B2B
Full Sensor Name (Sensor Name In SDR):
DIMMG%_Temp (% = Group number)
Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Non-Recoverable - Going High - Asserted
Message:
DIMM Group% temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, reseat the DIMMs and monitor the status.
4. If the error recurs, replace the DIMMs.
• Diagnostic Code:
0101092A
0101092B
Full Sensor Name (Sensor Name In SDR):
DIMMG%_Temp (% = Group number)
Appendix A. TMM error messages