Lenovo Converged HX Series Installation And Service Manual page 191

Table of Contents

Advertisement

Temperature
Event Severity:
Critical
Description:
Upper Non-Recoverable - Going High - Asserted
Message:
DIMM Group% VR temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, reseat the DIMMs and monitor the status.
4. If the error recurs, replace the DIMMs.
• Diagnostic Code:
0101092C
0101092D
0101092E
0101092F
Full Sensor Name (Sensor Name In SDR):
DIMM%_VR_Temp (% = Channel number)
Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Critical - Going High - Asserted
Message:
DIMM Group% VR temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, reseat the DIMMs and monitor the status.
4. If the error recurs, replace the DIMMs.
• Diagnostic Code:
0101072C
0101072D
0101072E
0101072F
Full Sensor Name (Sensor Name In SDR):
DIMM%_VR_Temp (% = Channel number)