Lenovo Converged HX Series Installation And Service Manual page 204

Table of Contents

Advertisement

Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Remove and install the power supply unit, and make sure it is properly connected to the power.
3. If the error recurs, replace the power supply units.
4. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
086F03A1
086F03A2
Full Sensor Name (Sensor Name In SDR):
PSU%_Status (% = PSU number)
Sensor Type:
Power Supply
Event Severity:
Critical
Description:
Power Supply input lost (AC/DC) - Asserted
Message:
AC lost
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Remove and install the power supply unit, and make sure it is properly connected to the power.
3. If the error recurs, replace the power supply units.
4. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
0B010BA3
0B010BA4
Full Sensor Name (Sensor Name In SDR):
PSU%_POUT (% = PSU number)
Sensor Type:
Other Units-based sensor
Event Severity:
Critical
Description:
Upper Non-Recoverable - Going High - Asserted
Message:
PSU output power is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.