Sensor Type:
Temperature
Event Severity:
Warning
Description:
Upper Non-Critical - Going High - Asserted
Message:
DIMM Group% VR temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, reseat the DIMMs and monitor the status.
4. If the error recurs, replace the DIMMs.
• Diagnostic Code:
0B010B91
Full Sensor Name (Sensor Name In SDR):
Node_IIN
Sensor Type:
Other Units-based sensor
Event Severity:
Critical
Description:
Upper Non-Recoverable - Going High - Asserted
Message:
Node input current is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. If the error recurs, contact Lenovo service representative for execution of node replacement.
3. If the error recurs, contact Lenovo service representative for execution of power interface board
replacement.
• Diagnostic Code:
0B010991
Full Sensor Name (Sensor Name In SDR):
Node_IIN
Sensor Type:
Other Units-based sensor
Event Severity:
Critical
Description:
178