Lenovo Converged HX Series Installation And Service Manual page 187

Table of Contents

Advertisement

Node_PBP_Temp
Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Non-Recoverable - Going High - Asserted
Message:
Power IC is over temperature
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
01010928
Full Sensor Name (Sensor Name In SDR):
Node_PBP_Temp
Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Critical - Going High - Asserted
Message:
Power IC is over temperature
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
01010728
Full Sensor Name (Sensor Name In SDR):
Node_PBP_Temp
Sensor Type:
Temperature
Event Severity:
Warning
Description:
Upper Non-Critical - Going High - Asserted
Appendix A. TMM error messages
173

Advertisement

Table of Contents
loading