• Diagnostic Code:
010109A5
010109A6
Full Sensor Name (Sensor Name In SDR):
PSU%_Temp (% = PSU number)
Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Critical - Going High - Asserted
Message:
PSU ambient temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Remove and install the power supply unit, and make sure it is properly connected to the power.
3. If the error recurs, replace the power supply units.
4. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
040104A7
040104A8
Full Sensor Name (Sensor Name In SDR):
PSU%_FAN_Speed (% = PSU number)
Sensor Type:
Fan
Event Severity:
Critical
Description:
Lower Non-Recoverable - Going Low - Asserted
Message:
PSU FAN speed is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check if the fan in the power supply unit is functioning. If not, replace the power supply unit.
3. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
04010BA7
04010BA8
Full Sensor Name (Sensor Name In SDR):
192