Lenovo Converged HX Series Installation And Service Manual page 185

Table of Contents

Advertisement

Message:
Outlet temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
01010722
01010723
Full Sensor Name (Sensor Name In SDR):
CPU0%_Temp
Sensor Type:
Temperature
Event Severity:
Warning
Description:
Upper Non-Critical - Going High - Asserted
Message:
CPU% temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Reseat the heat sink, and re-apply the thermal grease.
3. If the error recurs, contact Lenovo service representative for technical support.
• Diagnostic Code:
01010B26
01010B27
Full Sensor Name (Sensor Name In SDR):
CPU%_VR_Temp (% = CPU Number)
Sensor Type:
Temperature
Event Severity:
Critical
Description:
Upper Non-Recoverable - Going High - Asserted
Message:
CPU% VR temperature is too high
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
Appendix A. TMM error messages