Lenovo Converged HX Series Installation And Service Manual page 212

Table of Contents

Advertisement

Power Cycle - Asserted
Message:
The Power Cycle is triggered by watchdog.
Actions:
Information only. There is no need to do anything for this message.
• Diagnostic Code:
076F01C5
076F01C6
Full Sensor Name (Sensor Name In SDR):
CPU%_Status (% = CPU number)
Sensor Type:
Processor
Event Severity:
Critical
Description:
Thermal Trip - Asserted
Message:
CPU temperature is too high. At the same time, system will be shutdown.
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error remains, contact Lenovo service representative for execution of processor replacement.
• Diagnostic Code:
070301C7
Full Sensor Name (Sensor Name In SDR):
PROC_Hot
Sensor Type:
Processor
Event Severity:
Warning
Description:
State Asserted - Asserted
Message:
CPU begins to throttle because its temperature is too high.
Actions:
1. Check Lenovo Data Center Support site for an applicable retain tip or firmware update that applies to
this error.
2. Check the status of the fans. If any of the fans is broken, replace it with a new one.
3. If the error remains, contact Lenovo service representative for execution of processor replacement.
• Diagnostic Code:
198
Lenovo Converged HX3710, HX2710-E, HX3710-F Type 8689, Lenovo Converged HX Enclosure Type 5495 Installation and Service Guide