After a specified number of consecutive attempts (automatic or manual), the server reverts to the default
UEFI configuration and starts System Setup so that you can make the necessary corrections to the
configuration and restart the server. If the server is unable to successfully complete POST with the default
configuration, there might be a problem with the system board.
You can specify the number of consecutive restart attempts in System Setup. Restart the server and press
the key according to the on-screen instructions to display the LXPM system setup interface. For more
information, see the "Startup" section in the LXPM documentation compatible with your server at
sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_page.html
Recovery and RAS ➙ POST Attempts ➙ POST Attempts Limit. Available options are 3, 6, 9, and disable.
Voltage planar fault is displayed in the event log
Complete the following steps until the problem is solved.
1. Revert the system to the minimum configuration. See
required number of processors and DIMMs.
2. Restart the system.
• If the system restarts, add each of the removed items one at a time and restart the system each time
until the error occurs. Replace the item for which the error occurs.
• If the system does not restart, suspect the system board.
Unusual smell
Complete the following steps until the problem is solved.
1. An unusual smell might be coming from newly installed equipment.
2. If the problem remains, contact Lenovo Support.
Server seems to be running hot
Complete the following steps until the problem is solved.
Multiple compute nodes or chassis:
1. Make sure that the room temperature is within the specified range (see
2. Make sure that the fans are installed correctly.
3. Update the UEFI and XCC to the latest versions.
4. Make sure that the fillers in the server are installed correctly (see
procedures" on page 51
5. Use the IPMI command to ramp up the fan speed to the full fan speed to see whether the issue can be
resolved.
Note: The IPMI raw command should only be used by trained technicians and the each system has its
own specific IPMI raw command.
6. Check the management processor event log for rising temperature events. If there are no events, the
compute node is running within normal operating temperatures. Note that you can expect some
variation in temperature.
Cannot enter legacy mode after installing a new adapter
Complete the following procedure to solve the problem.
1. Go to UEFI Setup ➙ Devices and I/O Ports ➙ Set Option ROM Execution Order.
2. Move the RAID adapter with operation system installed to the top of the list.
3. Select Save.
ThinkSystem SR630 V3 User Guide
476
for detailed installation procedures).
. Then, click System Settings ➙
"Specifications" on page 3
"Specifications" on page
Chapter 5 "Hardware replacement
https://
for the minimally
3).

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d727d737d74

Table of Contents