About this task
Attention:
• Read
"Installation Guidelines" on page 51
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding systems.
• Do not touch the processor contacts. Contaminants on the processor contacts, such as oil from your skin,
can cause connection failures.
Note: The heat sink, processor, and processor carrier for your system might be different from those shown
in the illustrations.
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sr630v3/7d72/downloads/driver-
to see the latest firmware and driver updates for your server.
list/
• Go to
"Update the firmware" on page 433
Procedure
Step 1.
Install the Torx T30 nut.
Figure 70. Installing a Torx T30 nut into the heat sink
Note: Do not touch the gold contacts on the bottom of the processor.
a.
Rotate the anti-tilt wire bail inwards.
ThinkSystem SR630 V3 User Guide
114
and
"Safety inspection checklist" on page 52
68.
for more information on firmware updating tools.
to ensure that you