Auxiliary Area Bits/Words and PLC Setup Settings Related to Duplex Communications Units
8-6
Auxiliary Area Bits/Words and PLC Setup Settings Related
to Duplex Communications Units
8-6-1

Auxiliary Area

Word(s)
Bit(s)
A027
00 to 15
A042 to A049 00 to 15
A261
10
11
12
214
Name
Duplex Communications Unit
Operating Flags
Duplex Communications Switch
Cause Flags (See note.)
Error
Online
information for I/
Replacement
O table creation
Flag
Duplex
Communications
Unit Missing or
Non-Duplex
Communications
Unit Mounted
Flag
Duplex
Communications
Unit Verification
Error Flag
Function
Turn ON when the Communications Unit with the
corresponding unit number is in duplex operation.
ON: Duplex communications operation
OFF: Not in duplex communications operation
When an error occurs in the active Communications
Unit and operation is switched to the standby
Communications Unit, an error code will be stored to
show the cause of the error in the active
Communications Unit. (See note.) The code is set to
00 Hex if online replacement is performed for the
faulty Unit.
The corresponding bit in A436 will also turn ON.
Turns ON when a Basic I/O Unit, Special I/O Unit, or
CPU Bus Unit is being replaced online on the CPU
Rack, an Expansion Rack, or a Long-distance
Expansion Rack. If an attempt is made to generate
the I/O tables while this flag is ON, an I/O table
generation error will occur and the I/O tables will not
be created.
ON: During online replacement
OFF: I/O table creation completed normally.
Turns ON when a Duplex Communications Unit is not
mounted for a unit number specified for Duplex
Communications Units in the PLC Setup or the
mounted Unit does not support duplex operation. If an
attempt is made to generate the I/O tables while this
flag is ON, an I/O table generation error will occur and
the I/O tables will not be created.
ON: A Duplex Communications Unit is missing or
the mounted Unit does not support duplex
operation.
OFF: I/O table creation completed normally.
The corresponding bit in A434 will also turn ON.
Turns ON when the unit numbers or node addresses
of two Units specified as a pair of Duplex
Communications Units in the PLC Setup do not
agree. If an attempt is made to generate the I/O tables
while this flag is ON, an I/O table generation error will
occur and the I/O tables will not be created.
ON: Verification error
OFF: I/O table creation completed normally.
The corresponding bit in A435 will also turn ON.
Section 8-6