Functional Classification: Auxiliary Area Bits For Cj-Series Units - Omron NJ501-1 Series User Manual

Machine automation controller nj-series cpu unit hardware
Table of Contents

Advertisement

Appendices
 Functional Classification: Auxiliary Area Bits for CJ-series Units
Variable name
_CJB_IOUnitInfo
Basic I/O Unit
Information
_CJB_CBU00InitSta
CPU Bus Unit Ini-
tializing Flags
to
_CJB_CBU15InitSta
_CJB_SIO00InitSta
Special I/O Unit
Initializing Flags
to
_CJB_SIO95InitSta
_CJB_CBU00Restart
CPU Bus Unit
Restart Bits
to
_CJB_CBU15Restart
_CJB_SIO00Restart
Special I/O Unit
Restart Bits
to
_CJB_SIO95Restart
_CJB_SCU00P1ChgSta
Serial Communi-
to
cations Unit 0,
Port 1/2 Settings
_CJB_SCU00P2ChgSta
Changing Flags
_CJB_SCU15P1ChgSta
Serial Communi-
to
cations Units 1 to
15, Port 1/2 Set-
_CJB_SCU15P2ChgSta
tings Changing
Flags
Note All of the system-defined variables for EtherCAT communications status show the current status.
A-110
Meaning
Shows the status of the Basic I/O Unit alarm
output (load short-circuit protection).
TRUE: Load short-circuit
FALSE: No load short-circuit
The corresponding variable is TRUE during
initialization of the CPU Bus Unit.
The corresponding variable changes to
FALSE when the initialization is completed.
The numbers in the variables indicate the unit
numbers of the applicable Units.
The corresponding variable is TRUE during
initialization of the Special I/O Unit.
The corresponding variable changes to
FALSE when the initialization is completed.
The numbers in the variables indicate the unit
numbers of the applicable Units.
The CPU Bus Unit is restarted when the cor-
responding variable changes to TRUE. (It is
changed to FALSE by the system after the
CPU Bus Unit is restarted.)
The numbers in the variables indicate the unit
numbers of the applicable Units.
If you change the Restart Flag to TRUE with
an instruction, the restart process begins from
refresh processing in the next task period.
The Special I/O Unit is restarted when the
corresponding variable changes to TRUE. (It
is changed to FALSE by the system after the
Special I/O Unit is restarted.)
The numbers in the variables indicate the unit
numbers of the applicable Units.
If you change the Restart Flag to TRUE with
an instruction, the restart process begins from
refresh processing in the next task period.
TRUE when the parameters of the specified
port are being changed. TRUE when the
Change Serial Communications Parameter
(SerialSetup) instruction is being executed.
FALSE after the parameters are changed.
It is also possible for the user to indicate a
change in serial port settings by turning ON
the corresponding flag through the execution
of an instruction or a user operation.
Function
Data type
ARRAY
[0..3, 0..9,
0..7] OF
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
BOOL
NJ-series CPU Unit Hardware User's Manual (W500)
Range of
Reference
values
TRUE or
page A-121
FALSE
TRUE or
page A-121
FALSE
TRUE or
page A-122
FALSE
TRUE or
page A-122
FALSE
TRUE or
page A-122
FALSE
TRUE or
page A-123
FALSE
TRUE or
page A-123
FALSE