Xilinx VCU1287 User Manual page 23

Characterization board
Hide thumbs Also See for VCU1287:
Table of Contents

Advertisement

PROGRAM Pushbutton
Pressing the PROGRAM pushbutton SW7 (callout 15,
program pin of the FPGA.
DONE LED
The DONE LED DS17 (callout 13,
FPGA. When the DONE pin is High, DS17 lights indicating the FPGA is successfully
configured.
INIT LED
The dual-color INIT LED DS3 (callout 14,
During FPGA initialization, the INIT LED illuminates RED. When FPGA initialization has
completed, the LED illuminates GREEN.
System Controller
The VCU1287 board utilizes a Xilinx XC7Z010-CLG225 Zynq-7000 AP SoC U38 (callout 35,
Figure
2-1) system controller that can be used to:
Configure the FPGA using predefined selection of configuration bit files on an SD card
using 8-bit SelectMAP configuration
Select the output frequencies of the Super-Clock2 module over I2C
Monitor the onboard power system (PMBus)
See
Appendix D, System Controller
System Controller Reset
The SYS_POR pushbutton SW4 (callout 10,
controller power-on reset (SYS_POR). When SYS_POR is reasserted, the system controller is
reconfigured using the controller design stored on an attached SPI flash.
System Controller Status LEDs
DS1, DS12, DS16, and DS27 (callout 37,
DONE, STATUS, and ERROR status, respectively.
VCU1287 Characterization Board
UG1121 (v1.0) December 11, 2015
Chapter 3:
Figure
Figure
2-1) indicates the state of the DONE pin of the
Figure
2-1) indicates the FPGA initialization status.
for information on the system controller menu options.
Figure
2-1) asserts the active-Low system
Figure
2-1) show the system controller INIT_B,
www.xilinx.com
Board Component Descriptions
2-1) asserts the active-Low