3.6
Resetting Default Values
3.6.1.
Reset the Master Code
Warning: Remove power from all devices
before connecting or removing the
DS12R.
1. Remove power from the DS12R.
2. Place the jumper across the PROG P1 jumper pins
(ON).
Refer to Figure 14.
Figure 14: DS12R PCB
1- RS-485 DIP Switches
2- PROG P1 Jumper
3- SMODE P3 Jumper
3. Reapply power to the DS12R.
4. Remove the jumper (OFF).
3.6.2.
Reset Programming Default Values
1. Enter Programming Mode.
2. Enter [9][9][*] Program Address 99.
3. Enter 18 for the programming value ([1][8]).
4. Press and hold [PROGRAM] for 3 sec to exit from
Programming Mode.
The DS12R resets all programming values to the
original factory defaults.
Bosch Security Systems, Inc. | 5/08 | F01U081956-01
DS12R | Installation and Operation Guide | Programming
3.7
Configuring the Working Mode
The DS12R can be used as stand-alone system or as a
component of an MTS system.
3.7.1.
Configure as a Stand-alone System
1. Remove power from the DS12R.
2. Place the jumper across the SMODE P3 jumper
pins (ON).
3. Reapply power to the DS12R. Refer to Figure 14.
3.7.2.
Configure for use in an MTS system
1. Remove power from the DS12R.
2. Remove the jumper across the PROG P3 jumper
pins (OFF).
3. Reapply power to the DS12R. Refer to Figure 14.
17