2.0 Programming

The control panel programming options are stored in
a non-volatile EPROM. This memory holds all
configuration and user-specific data even after a total
power loss.
Because the data retention time is up to ten years
without power, no reprogramming is required after
powering down the control panel.
You can change data as many times as necessary
without any additional specialized equipment. The
memory is organized in locations, each of which
holds the data for a specific function.
15 is the maximum value that you can
program into any location.
In general, the entire programming sequence consists
of selecting the required location, and then entering
or changing the current data. Repeat this procedure
until you program all the required data. The factory
default settings are selected for reporting to the
monitoring station in Contact ID format.
The Installer Code provides access only to the
Installer's Programming Mode and does not allow
you to arm and disarm the system. You cannot enter
Installer's Programming Mode when the system is
armed, or at any time during siren run time.
You can program the ICP-CC404 Control Panel
using any of these three devices:
Remote codepad
CC816 Alarm Link Upload/Download Software
2.1
Programming with the Remote
Codepad
To program the control panel using the remote
codepad, the system must be disarmed with no alarm
memory present.
To access Installer's Programming Mode:
Enter the four-digit Installer Code (the factory default
is 1234) and press [AWAY].
Two beeps sound and both the AWAY and the
STAY indicators flash simultaneously to indicate that
you entered Installer's Programming Mode.
When you enter Installer's Programming Mode, you
are automatically positioned at Location 000, the first
digit of the Primary Telephone Number for Receiver
1. The codepad indicators display the current data
stored in this location.
Bosch Security Systems, Inc. | 12/08 | F01U089401-02
ICP-CC404 | Installation Guide | 2.0
Table 3:
Codepad Indicators
Data
Zone Indicators
Value
1
2
3
4
0
1
X
2
X
3
X
4
X
5
6
7
8
9
X
10
11
X
12
X
13
X
14
X
15
To move to a different programming location:
Enter the location number and press [AWAY].
For example, press [3 4][AWAY] to automatically
step you to the beginning of the Subscriber ID
Number for Receiver 1. The data stored in the new
location appears.
To move to the next location:
Press [AWAY].
For example, if you are currently positioned at
Location 034, press [AWAY] to step to Location 035.
To move to the previous location:
Press [STAY].
For example, if you are positioned at Location 035,
press [STAY] to step back to Location 034.
To change data in the current location:
Enter the new value (0 to 15) and press [STAY].
The data is stored and you remain positioned at the
same location. The codepad indicators show the new
value (for example, if you enter [1 4] and press
[STAY], the Zone 4 and MAINS indicators light).
To exit from the Installer's Programming Mode:
Enter command [9 6 0] and press [AWAY].
Two beeps sound and the STAY and AWAY
indicators turn off. The system returns to the
disarmed state and is now ready for use.
Refer to Section 2.4 Installer's Programming Commands
on page 10 for more information about using
Installer's Programming Mode.
Programming
5
6
7
8
MAINS
X
X
X
X
X
X
X
X
X
X
X
X
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents