Introduction
FPI-Regency Fireplaces Products of Delta, BC, contracted with PFS-TECO to perform
EPA certification testing on I2450M Wood-Fired Room Heater. All testing was performed
at PFS-TECO's Portland Laboratory. Testing was performed by Sebastian Button and
Aaron Kravitz.
Notes
• Prior to start of testing, 50 hours of conditioning was performed by FPI lab staff as
a medium burn setting using fuel with a dry moisture content of 18-28%, per ASTM
E3053.
• Prior to start of testing, the dilution tunnel was cleaned with a steel brush.
• Front filters were changed on sample train A at one hour for all 4 test runs.
• A total of 4 test runs were attempted. One run was aborted due to a sampling
proportionality violation, so it produced no results. Three complete test runs were
performed in accordance with ASTM E3053. For the three test runs used in the
weighted average, no anomalies occurred. See the Run Narrative section for
further detail on each run.
Page | 4
Project # 19-469
Model: I2450M