Run 4
BOX B TEST DATA - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
I2450
Run #:
4
Gas Meter
Elapsed
Sample
3
Time (min)
Rate (cfm)
(ft
)
448
66.774
0.148
449
66.926
0.152
450
67.076
0.150
451
67.226
0.150
452
67.376
0.150
453
67.524
0.148
454
67.676
0.152
455
67.824
0.148
456
67.977
0.153
457
68.124
0.147
458
68.277
0.153
459
68.424
0.147
460
68.576
0.152
461
68.724
0.148
462
68.875
0.151
463
69.025
0.150
464
69.176
0.151
465
69.326
0.150
466
69.475
0.149
467
69.626
0.151
468
69.774
0.148
469
69.926
0.152
470
70.074
0.148
471
70.227
0.153
Avg/Tot
70.227
0.149
PFS-TECO
Job #:
Tracking #:
Technician:
Date:
Particulate Sampling Data
Meter
Orifice dH
Meter
Vacuum
(in H
O)
Temp (°F)
2
(in Hg)
2.22
108
-2.84
2.22
107
-2.01
2.21
108
-1.45
2.22
107
-2.09
2.23
107
-2.2
2.21
107
-2.29
2.23
108
-2.25
2.22
107
-1.98
2.23
107
-1.3
2.22
107
-1.38
2.21
107
-2.39
2.23
107
-2.57
2.22
107
-1.35
2.22
107
-2.47
2.23
107
-1.31
2.22
107
-1.29
2.22
107
-2.22
2.22
107
-2.7
2.23
107
-2.54
2.24
107
-2.68
2.24
107
-1.34
2.24
107
-2.76
2.22
107
-2.78
2.22
107
-2.63
2.21
105
-2.11
Page 39 of 50
19-469
0025
ADK
4/11/2019
Flue Draft
Pro. Rate
Filter (°F)
(in H
(%)
101
87
98
85
100
87
97
86
98
86
98
87
100
86
98
85
100
85
98
86
98
86
99
86
100
87
102
86
99
86
100
85
102
86
100
86
99
86
100
86
97
86
98
86
96
86
102
85
100
Flue Gas Data
CO
(%)
CO (%)
2
O)
2
-0.050
2.97
0.50
-0.040
2.97
0.46
-0.050
2.98
0.49
-0.040
3.07
0.48
-0.030
3.07
0.49
-0.030
2.96
0.48
-0.050
2.96
0.50
-0.040
2.97
0.51
-0.030
3.05
0.48
-0.060
2.87
0.51
-0.040
2.90
0.54
-0.020
2.86
0.51
-0.040
2.75
0.50
-0.040
2.82
0.48
-0.040
2.84
0.48
-0.040
2.83
0.49
-0.050
2.90
0.49
-0.030
3.08
0.47
-0.060
2.87
0.49
-0.050
2.83
0.46
-0.050
2.84
0.46
-0.040
2.75
0.45
-0.040
2.65
0.47
-0.040
2.72
0.50
4.52