FPI Regency H2100 Owners & Installation Manual

FPI Regency H2100 Owners & Installation Manual

Wood fireplace inserts & hearth heater

Advertisement

Quick Links

WOOD
Fireplace
Inserts &
www.regency-fi re.com
Hearth Heater
Owners & Installation Manual
MODELS:
H2100
I1100S
I3100L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
908-332b
06/02/06

Advertisement

Table of Contents
loading

Summary of Contents for FPI Regency H2100

  • Page 1 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 908-332b 06/02/06...
  • Page 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS REGENCY FIREPLACE INSERTS & HEARTH HEATER SAFETY LABEL OPERATING INSTRUCTIONS Safety Label For I1100S & I3100L .........4 First Fire ..............13 Safety Label For H2100M ..........5 Fan Operation (All Units) ..........13 Ash Disposal ...............13 Some Safety Guidelines ..........13 INSTALLATION Creosote ..............14 Before Installing Your Insert ..........6...
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Small Flush Insert and Large Flush improved. Check the label on the unit and if Insert. We have printed a copy of the contents there is a difference, the label on the unit is here for your review.
  • Page 5: Safety Label For H2100M

    SAFETY LABEL This is a copy of the label that accompanies each NOTE: Regency units are constantly being Regency Hearth Heater. We have printed a improved. Check the label on the unit and if copy of the contents here for your review. there is a difference, the label on the unit is the correct one.
  • Page 6: Installation

    INSTALLATION Regency Inserts are constructed with the high- CHIMNEY 9) Means must be provided for removal of the est quality materials and assembled under strict insert to clean the chimney fl ue. SPECIFICATIONS quality control procedures that insure years of 10) Inserts that project in front of the fi...
  • Page 7: Optional Flue Connector Kit

    INSTALLATION Position the grill on the inside bodyface side and OPTIONAL FLUE fasten using the bolts, washers and nuts provided CONNECTOR KIT (2 per side) as shown in the diagrams. The optional Flue Connector Kit (Part # 846-527) and the Straight Flue Adaptor (Part #846-504) shown here, may be used to produce a secure connection between your fl...
  • Page 8: Leg Option On H2100 Hearth Heater

    INSTALLATION LEG OPTION ON H2100 INSTALLATION INTO A In Canada this fi replace insert must be in- stalled with a continuous chimney liner of 6" HEARTH HEATER MASONRY FIREPLACE diameter extending from the fi replace insert to the top of the chimney. The chimney liner The addition of legs to the Hearth Heater does When referencing installation or connec- must conform to the Class 3 requirements...
  • Page 9: Faceplate And Trim

    INSTALLATION 4) If the fl oor of your fi replace is below the 3) Attach the assembled faceplate to the faceplate mounting brackets. level of the fi replace opening, adjust the insert's levelling bolts to accommodate the difference. When additional shimming is required, use non-combustible masonry or steel shims.
  • Page 10: Fan / Blower

    INSTALLATION FAN / BLOWER Do not turn fan ON until your insert has Your fan should only be installed once the unit is 3) Slide the supports into the clips. The tension reached operating temperature or at least in place in order to prevent any damage to the holding the clips in place may be adjusted by 30 minutes after starting fi...
  • Page 11: Floor Protection

    INSTALLATION FLOOR PROTECTION BRICK FLUE BAFFLE & SECONDARY AIR TUBE Please check to ensure that your fl oor protection and hearth will meet the standards for clearance INSTALLATION to combustibles. Your hearth extension must be made from a non-combustible material. The fl...
  • Page 12: Draft Control

    INSTALLATION Small Insert I1100S Hearth Heater (H2100M) 1) If the two air tubes are installed continue on Steel Baffl e to Step 2), if not, follow the instructions below. Install the air tube into the holes in the side Pull Open Push Closed Place the insulation batt on top of the baffl...
  • Page 13: Operating Instructions

    OPERATING INSTRUCTIONS 10) For those units installed at higher elevations FIRST FIRE automatic temperature sensor will engage the or into sub-standard masonry fi replaces, blower when the unit is at temperature and will drafting problems may occur. Consult an shut off the blower once the fi re has gone out When your installation is completed and in- experienced dealer or mason on methods and the unit has cooled to below a useful heat...
  • Page 14: Creosote

    MAINTENANCE 6) Do not permit creosote or soot buildup in the Removal for Cleaning etc. DOOR LATCH chimney system. Check and clean chimney ADJUSTMENT at regular intervals. Removal of your insert for cleaning purposes is usually not required if a proper installation 7) Your Regency Insert can be very hot.
  • Page 15: Parts List

    PARTS LIST I1100 & I3100 MAIN ASSEMBLY Part # Description 846-913 Door Assembly-Small Gold (I1100)-no glass 846-915 Door Assembly-Small Black (I1100)-no glass 846-910 Door Assembly-Large Gold (I3100)-no glass 846-916 Door Assembly-Large Black (I3100)-no glass 846-302 Glass - Replacement - (I1100) 846-304 Glass - Replacement - (I3100) 936-243...
  • Page 16: I1100 & I3100 Faceplates

    PARTS LIST I1100 & I3100 FACEPLATES Part # Description Part # Description Faceplate: I1100S Faceplate: I3100L 170-911 Faceplate & Trim Set - Regular 163-910 Faceplate & Trim Set - Regular 185) 170-160 Trim Right Regular 385) 163-165 Trim Right Regular 186) 170-159 Trim Top Regular 386) 163-160...
  • Page 17: H2100 Main Assembly

    PARTS LIST H2100 MAIN ASSEMBLY Part # Description Part # Description 37) 836-212 Baffl e Insulation 846-910 Door Assembly-Large Gold - no glass 38) * Insulation Weights 846-916 Door Assembly-Large Black - no glass 39) 120-950 Steel Baffl e 846-304 Glass - Replacement 948-216 Regency Logo...
  • Page 18: I1100, I3100 & H2100 Firebrick

    PARTS LIST I1100, I3100 & H2100 FIREBRICK Part # Description 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 71) 802-104 Brick Partial: 1-1/4" x 4" x 9" 72) 802-146 Brick Partial: 1-1/4" x 1-3/4" x 9" 75) 802-139 Brick Partial: 1-1/4"...
  • Page 19: Warranty

    At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured.
  • Page 20 ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd. Printed in Canada © Copyright 2006, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Regency i1100sRegency i3100l

Table of Contents