Run 2
Sample Calculations – ASTM E3053 & E2515
Client:
Model:
Run:
Equations used to calculate the parameters listed below are described in this appendix. Sample
calculations are provided for each equation. The raw data and printout results from a sample run are
also provided for comparison to the sample calculations.
M
– Weight of test fuel load, dry basis, lb (kg)
Fldb
M
– Weight of start-up fuel, dry basis, lb (kg)
SUdb
M
- Weight of kindling, dry basis, lb (kg)
Kdb
M
- Total weight of all remaining fuel at end of high fire test run, lb (kg)
FREHdb
M
- Total weight of all fuel burned during high fire test run, lb (kg), dry basis
TFBHdb
BR
– Dry burn rate for high fire test run, from time when test fuel load is added to end of test run, lb/h
H
(kg/h)
M
- Total weight of fuel burned during low or medium fire test run, lb (kg), dry basis
TFBdb
BR - Dry burn rate for low and medium fire test runs, lb/h (kg/h)
V
– Average gas velocity in the dilution tunnel, ft/sec
s
Q
– Average gas flow rate in dilution tunnel, dscf/hr
sd
V
– Volume of gas sampled, corrected to dry standard conditions, dscf
m(std)
m
– Total particulate matter collected, mg
n
C
- Concentration of particulate matter in tunnel gas, dry basis, corrected to STP, g/dscf
s
E
– Total particulate emissions, g
T
PR - Proportional rate variation
PM
- Particulate emission rate for high fire test run, g/hr
RH
PM
- Particulate emission factor for high fire test run, g/dry kg of fuel burned
FH
PM
– Particulate emission rate for low or medium fire test run, g/hr
R
PM
– Particulate emission factor for low or medium fire test run, g/dry kg of fuel burned
F
PFS-TECO
FPI
I2450
2
Page 1 of 17