12. Slide the unit back until the flue adaptor is slightly
engaged. At this point it is recommended to level
the unit. This will keep the adaptor from binding.
13. Insert the provided pull rod through the hole in
the top center of the unit. Secure the threaded
end into the flue adaptor as shown in diagram
4. While sliding the unit into place pull on the
rod to ensure that the flue adaptor is properly
engaged. See Diagram 5. Double check the
adaptor is seated properly and the pull rod in
the firebox, locate the two holes lined up to the
two holes on the adaptor.
Pull Rod
Diagram 4
Pull Rod in place
Diagram 5
14. Use the two bolts, washers and lock washers
(supplied in manual pack) and install them,
tighten down using the 1/2" socket to ensure
the adapter is positively secured to the unit.
Once completed remove pull rod and place
away for future re-install.
Diagram 6
15. Reverse steps 6-3 to complete the installation.