EPA Certification Test Report
The following models are EPA certified under the following attached test report:
Wood Stoves
Wood Inserts
Wood Fireplaces
Pellet Stoves
Pellet Inserts
Full US Environmental Protection Agency ("EPA") certification test reports have been reported to the
EPA. Test reports may contain sensitive, confidential business information which has been specifically
excluded and/or redacted from this publicly posted test report.
_____________________________________________________________________________________
© FPI FIREPLACE PRODUCTS INTERNATIONAL LTD
Published February 16, 2022
i2450/Hi2450
Model #
N/A
i2450
Hi2450
N/A
N/A
N/A
E&OE

Advertisement

Table of Contents
loading

Summary of Contents for FPI I2450M

  • Page 1 Full US Environmental Protection Agency (“EPA”) certification test reports have been reported to the EPA. Test reports may contain sensitive, confidential business information which has been specifically excluded and/or redacted from this publicly posted test report. _____________________________________________________________________________________ © FPI FIREPLACE PRODUCTS INTERNATIONAL LTD Published February 16, 2022 E&OE...
  • Page 2 Fireplace Products International, Ltd. Project # 19-469 Model: I2450M AKA: HI2450M Type: Wood-Fired Fireplace Insert April 23, 2019 Revised: June 24, 2021, February 16, 2022 ASTM E3053 Standard Test Method for Determining Particulate Matter Emissions from Wood Heaters Using Cordwood Test Fuel (EPA ALT-125) Contact: Mr.
  • Page 3 Project # 19-469 Model: I2450M Revision Summary Date: 4/23/2019 – Original Issue Date: 6/24/2021 – The following revisions were made per a request from EPA: -Run 2 lab sample data page in Appendix A was cleaned up to reduce confusion with some weights, no changes made to final catch numbers, see page 105 in Non-CBI report.
  • Page 4: Table Of Contents

    Project # 19-469 Model: I2450M Contents Affidavit ................................. 3 Introduction ..............................4 Notes ................................. 4 Wood Heater Identification and Testing ......................5 Test Procedures and Equipment ........................6 Results ................................7 Summary Table ............................7 Test Run Narrative ............................ 8 Run 1 ..............................
  • Page 5: Affidavit

    Affidavit PFS-TECO was contracted by Fireplace Products International Ltd. (FPI) to provide testing services for the I2450M Wood-Fired Room Heater per ASTM E3053, Standard Test Method for Determining Particulate Matter Emissions from Wood Heaters Using Cordwood Test Fuel, which was approved for use under EPA ALT-125. All testing and associated procedures were conducted at PFS-TECO’s Portland Laboratory beginning...
  • Page 6: Introduction

    PFS-TECO’s Portland Laboratory. Testing was performed by Sebastian Button and Aaron Kravitz. Notes • Prior to start of testing, 50 hours of conditioning was performed by FPI lab staff as a medium burn setting using fuel with a dry moisture content of 18-28%, per ASTM E3053.
  • Page 7: Wood Heater Identification And Testing

    • Test Location: PFS-TECO Portland Laboratory 11785 SE HWY 212 - Suite 305, Clackamas, OR 97015 • Elevation: ~ 131 Feet above sea level Sebastian Button & Aaron Kravitz • Test Technician(s): Radu Costei of FPI. • Observers: Page | 5...
  • Page 8: Test Procedures And Equipment

    Project # 19-469 Model: I2450M Test Procedures and Equipment All Sampling and analytical procedures were performed by Sebastian Button. procedures used are directly from ASTM E3053 and ASTM E2515. See the list below for equipment used. See Appendix C submitted with this report for calibration data.
  • Page 9: Results

    Higher Heating Value efficiency of 67.0%. The average CO emission rate for the 3 tests was 1.43 g/min. The FPI I2450M Wood-Fired Room Heater meets the 2020 cordwood PM emission standard of ≤ 2.5 g/hr per CFR 40 part 60, §60.532 (c).
  • Page 10: Test Run Narrative

    Project # 19-469 Model: I2450M Test Run Narrative Run 1 Run 1 was performed on 4/8/2019 as a high fire test run per ASTM E3053. Emissions sampling began from a cold start ignition of kindling and start-up fuel. The test fuel load was loaded 26 minutes into the test.
  • Page 11: Test Conditions Summary

    Project # 19-469 Model: I2450M Test Conditions Summary Testing conditions for all runs fell within allowable specifications of ASTM E3053 and ASTM E2515. A summary of facility conditions, fuel burned, and run times is listed below. Average Preburn Relative Test Fuel...
  • Page 12: Appliance Description

    Flue Outlet: 6-inch exhaust outlet located on the top of the appliance. Catalytic Combustor: N/A Fan: The I2450M is equipped from the factory with a convection fan that attached to the front of the appliance beneath the loading door. Appliance Dimensions...
  • Page 13: Firebox Volume

    Project # 19-469 Model: I2450M Firebox Volume Page | 11...
  • Page 14 Project # 19-469 Model: I2450M Appliance Front Appliance Left Page | 12...
  • Page 15 Project # 19-469 Model: I2450M Appliance Right Appliance Rear Page | 13...
  • Page 16: Test Fuel Properties

    Project # 19-469 Model: I2450M Test Fuel Properties Test fuel used was Maple cordwood, split and air-dried to the specified moisture content range. Typical fuel loads are pictured below: Typical Kindling Load Typical Startup Load Typical High Fire Load Typical Low Fire Load...
  • Page 17: Sampling Locations And Descriptions

    Project # 19-469 Model: I2450M Sampling Locations and Descriptions Sample ports are located 16.5 feet downstream from any disturbances and 1 foot upstream from any disturbances. Flow rate traverse data was collected 12 feet downstream from any disturbances and 5.5 feet upstream from any disturbances. (See below).
  • Page 18: Sampling Methods

    Project # 19-469 Model: I2450M Sampling Methods ASTM E2515 was used in collecting particulate samples. The dilution tunnel is 6 inches in diameter. All sampling conditions per ASTM E2515 were followed. No alternate procedures were used with the exception of caveats described in ALT-125: Pall TX40 Emfab filters were used, filter temperatures were maintained between 80 and 90°F for all...
  • Page 19: Sealed Unit

    Project # 19-469 Model: I2450M Sealed Unit Page | 17...
  • Page 20: List Of Appendices

    Project # 19-469 Model: I2450M List of Appendices The following appendices have been submitted electronically in conjunction with this report: Appendix A – Test Run Data, Technician Notes, Sample Analysis, and Alternate Test Method Approval Appendix B – Labels and Manuals Appendix C –Equipment Calibration Records...
  • Page 21 Conditioning Data.xlsm Conditioning Data Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Date(s): 3/20/19 - 4/1/2019 Technician: Average: 324.8 69.5 Elapsed Time Scale Reading Weight Catalyst Exit Flue (°F) Ambient (°F) (hrs) (lbs) Change (lbs) (°F) 26.0 15.2 -10.8 -8.2 -2.9 -1.0...
  • Page 22 WOOD HEATER TESTING SUMMARY SECTION 1 – Model Identification Model Name(s)/Number(s) I2450, HI2450 Manufacturer FPI - Regency Fireplaces Products Address 1 6988 Venture St. Address 2 Delta, BC V4G 1H4 Appliance Category(s) (Free-standing, Insert, etc.) Fireplace Insert Usable Firebox Volume - ft 2.24...
  • Page 23 SECTION 2 – Test Conditions Summary Model Name(s)/Number(s) I2450, HI2450 Usable Firebox Volume - ft 2.24 Optional Convection Air Fan (No, Standard, Optional) Test Run # Date Tested 4/9/2019 4/11/2019 4/8/2019 Test Run Category (L, M, H) Average Barometric Pressure - in Hg 30.13 29.96 29.86...
  • Page 24 SECTION 3 – Test Run Results Summary Model Name(s)/Number(s) I2450, HI2450 Usable Firebox Volume - ft 2.24 Optional Convection Air Fan (No, Standard, Optional) Test Run # Date Tested 4/9/19 4/11/19 4/8/19 Test Run Category Burn Rate - kg/h DB 1.10 1.25 2.74...
  • Page 25 SECTION 4 - Weighted Average Summary Model Name(s)/Number(s) I2450, HI2450 Usable Firebox Volume - ft 2.24 Optional Convection Air Fan (No, Standard, Optional) Average for Each Test Run Category Burn Rate - kg/h DB 1.10 1.25 2.74 PM Emission Rate - g/h 0.78 0.89 3.58...
  • Page 26 Emission testing instructions I2450 Volume: 2.24 cu.ft. Low and Medium High before Low and Medium – no sampling. Air set to High Setting Fan on high at 20 min after loading main fuel load Kindling – 3.0lb Startup fuel – 4.0lb Procedure Start with a couple pieces of crumbled paper in between and 1.7 lbs kindling.
  • Page 27 At 13-14 min set to Low setting. Fan on low at 30 min.
  • Page 28 WOOD STOVE TEST DATA PACKET ASTM E3053/E2515 Run 1 Data Summary Client: Model: I2450 Job #: 19-469 Tracking #: 0025 Test Date: 4/8/2019 4/19/2019 Techician Signature Date PFS-TECO Page 1 of 23...
  • Page 29 Run 1 TEST RESULTS - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Burn Rate (kg/hr): 2.74 Ambient Sample Sample 1st Hour Sample Train A Train B Filter Total Sample Volume (ft 22.014 28.203...
  • Page 30 Run 1 B415.1 Efficiency Results Manufacturer: Model: I2450 Date: 04/08/19 Run: Control #: 19-469 Test Duration: Output Category: High Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 66.0% 70.6% Combustion Efficiency 98.0% 98.0% Heat Transfer Efficiency 67.4% 72.1% Output Rate (kJ/h)
  • Page 31 Run 1 HIGH FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 22.40 Total Load Weight Range (lbs): 21.30...
  • Page 32 Run 1 DILUTION TUNNEL & MISC. DATA - ASTM E3053 / E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Test Start Time: Date: 4/8/2019 Test Type: High Fire Pre-Test Post Test Avg. Recording Interval (min): Barometric Pressure (in.
  • Page 33 Run 1 WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Recording Interval (min): Run Time (min): High Fire Test Begins from Cold Start, No Preburn is Performed Temperatures (°F) Elapsed Scale Stove Flue Draft...
  • Page 34 Run 1 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 35 Run 1 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 36 Run 1 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 37 Run 1 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 38 Run 1 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 39 Run 1 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 40 Run 1 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Elapsed Sample Orifice dH Meter Pro.
  • Page 41 Run 1 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Elapsed Sample Orifice dH Meter Pro.
  • Page 42 Run 1 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Elapsed Sample Orifice dH Meter Pro.
  • Page 43 Run 1 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Elapsed Sample Orifice dH Meter Pro.
  • Page 44 Run 1 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Elapsed Sample Orifice dH Meter Pro.
  • Page 45 Run 1 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Elapsed Sample Orifice dH Meter Pro.
  • Page 46 Run 1 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 77.8 78.0...
  • Page 47 Run 1 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 408.4 409.2...
  • Page 48 Run 1 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 428.6 428.6...
  • Page 49 Run 1 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 379.4 377.4...
  • Page 50 Run 1 LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/8/2019 TRAIN A (1st Hour) Weights Filter, Probe, or Sample Component Sample Type O-Ring # Final, mg Tare, mg Particulate, mg A.
  • Page 51 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 1 Test Date: 4/8/2019 Wood Heater Run Notes Test Notes Test Burn Start Time: 11:50 Air Control Setting: Fully Open Time Notes 0:00 Started with 1.7 lbs kindling and torch for 20 sec, door cracked...
  • Page 52 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 1 Test Date: 4/8/2019 Test Photos Kindling Fuel Load Start-up Fuel Load High Fire Fuel Load Residual Start-up Fuel Coal Bed Technician Signature:...
  • Page 53 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 1 Test Date: 4/8/2019 High Fire Fuel Loaded Technician Signature: Date: 4/8/2019 Page 3 of 3...
  • Page 54 WOOD STOVE TEST DATA PACKET ASTM E3053/E2515 Run 2 Data Summary Client: Model: I2450 Job #: 19-469 Tracking #: 0025 Test Date: 4/9/2019 6/24/2021 Techician Signature Date PFS-TECO Page 1 of 53...
  • Page 55 Run 2.xlsm TEST RESULTS - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Burn Rate (kg/hr): 1.10 Ambient Sample Sample 1st Hour Sample Train A Train B Filter Total Sample Volume (ft 61.013 80.013...
  • Page 56 Run 2.xlsm B415.1 Efficiency Results Manufacturer: Model: I2450 Date: 04/09/19 Run: Control #: 19-469 Test Duration: Output Category: Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 68.2% 73.0% Combustion Efficiency 95.0% 95.0% Heat Transfer Efficiency 71.8% 76.8% Output Rate (kJ/h)
  • Page 57 Run 2.xlsm HIGH FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 22.40 Total Load Weight Range (lbs): 21.30...
  • Page 58 Run 2.xlsm LOW & MEDIUM FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 26.88 Total Load Weight Range (lbs): 25.54...
  • Page 59 Run 2.xlsm DILUTION TUNNEL & MISC. DATA - ASTM E3053 / E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Test Start Time: Date: 4/9/2019 Test Type: Low Fire Recording Interval (min): Pre-Test Post Test Avg.
  • Page 60 Run 2.xlsm WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 61 Run 2.xlsm WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 62 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 63 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 64 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 65 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 66 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 67 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 68 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 69 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 70 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 71 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 72 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 73 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 74 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 75 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 76 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 77 Run 2.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 78 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 79 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 80 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 81 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 82 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 83 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 84 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 85 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 86 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 87 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 88 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 89 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 90 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 91 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 92 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 93 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 94 Run 2.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 95 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 432.6 432.4...
  • Page 96 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 416.2 415.0...
  • Page 97 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 379.8 380.0...
  • Page 98 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 352.6 351.4...
  • Page 99 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 333.8 332.6...
  • Page 100 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 304.6 304.4...
  • Page 101 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 302.6 302.6...
  • Page 102 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 295.2 295.4...
  • Page 103 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 285.2 285.0...
  • Page 104 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 272.8 272.8...
  • Page 105 Run 2.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 265.8 265.6...
  • Page 106 Run 2.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/9/2019 TRAIN A (1st Hour) Weights Filter, Probe, or Sample Component Sample Type O-Ring # Final, mg Tare, mg Particulate, mg T136 87.6...
  • Page 107 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 2 Test Date: 4/9/2019 Wood Heater Run Notes Pre-Test Notes Pre-Test Start Time: 08:20 Air Control Setting: Fully Open Time Notes 0:00 Started PB with 1.8 lb, torch for 25 sec...
  • Page 108 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 2 Test Date: 4/9/2019 Test Photos Kindling Fuel Load Start-up Fuel Load High Fire Fuel Load Kindling Loaded Technician Signature: Date: 4/19/2019...
  • Page 109 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 2 Test Date: 4/9/2019 High Fire Fuel Loaded Residual High Fire Load Coal Bed Low Fire Fuel Load Low Fire Fuel Loaded...
  • Page 110 WOOD STOVE TEST DATA PACKET ASTM E3053/E2515 Run 3 Data Summary Client: Model: I2450 Job #: 19-469 Tracking #: 0025 Test Date: 4/10/2019 6/24/2021 Techician Signature Date PFS-TECO Page 1 of 19...
  • Page 111 Run 3.xlsm TEST RESULTS - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Burn Rate (kg/hr): 6.31 Incomplete Test Run - Results could not be computed Ambient Sample Sample 1st Hour Sample...
  • Page 112 Run 3.xlsm B415.1 Efficiency Results Manufacturer: Model: I2450 Date: 04/10/19 Run: Control #: 19-469 Test Duration: Output Category: Medium Test Results in Accordance with CSA B415.1-09 Incomplete Test Run - Results could not be computed HHV Basis LHV Basis Overall Efficiency 63.7% 68.2% Combustion Efficiency...
  • Page 113 Run 3.xlsm HIGH FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 22.40 Total Load Weight Range (lbs): 21.30...
  • Page 114 Run 3.xlsm LOW & MEDIUM FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 26.88 Total Load Weight Range (lbs): 25.54...
  • Page 115 Run 3.xlsm DILUTION TUNNEL & MISC. DATA - ASTM E3053 / E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Test Start Time: 11:43 Date: 4/10/2019 Test Type: Medium Fire Recording Interval (min): Pre-Test Post Test Avg.
  • Page 116 Run 3.xlsm WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 117 Run 3.xlsm WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 118 Run 3.xlsm WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 119 Run 3.xlsm WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 120 Run 3.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 121 Run 3.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 122 Run 3.xlsm BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter...
  • Page 123 Run 3.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 124 Run 3.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 125 Run 3.xlsm BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter...
  • Page 126 Run 3.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 392.2 392.4...
  • Page 127 Run 3.xlsm WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 320.6 318.6...
  • Page 128 Run 3.xlsm LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: ADK/SJB Date: 4/10/2019 TRAIN A (1st Hour) Incomplete Test Run - Results could not be computed, filter samples were not weighed Weights Filter, Probe, or Sample Component...
  • Page 129 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 3 Test Date: 4/10/2019 Wood Heater Run Notes Pre-Test Notes Pre-Test Start Time: 09:30 Air Control Setting: Fully Open Time Notes 0:00 Started PB with 1.8 lb, torch for 20 sec...
  • Page 130 WOOD STOVE TEST DATA PACKET ASTM E3053/E2515 Run 4 Data Summary Client: Model: I2450 Job #: 19-469 Tracking #: 0025 Test Date: 4/11/2019 4/19/2019 Techician Signature Date PFS-TECO Page 1 of 50...
  • Page 131 Run 4 TEST RESULTS - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Burn Rate (kg/hr): 1.25 Ambient Sample Sample 1st Hour Sample Train A Train B Filter Total Sample Volume (ft 53.274 70.888 70.227...
  • Page 132 Run 4 B415.1 Efficiency Results Manufacturer: Model: I2450 Date: 04/11/19 Run: Control #: 19-469 Test Duration: Output Category: Medium Test Results in Accordance with CSA B415.1-09 HHV Basis LHV Basis Overall Efficiency 66.4% 71.0% Combustion Efficiency 95.9% 95.9% Heat Transfer Efficiency 69.2% 74.0% Output Rate (kJ/h)
  • Page 133 Run 4 HIGH FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 22.40 Total Load Weight Range (lbs): 21.30...
  • Page 134 Run 4 LOW & MEDIUM FIRE FUEL LOAD DATA - ASTM E3053 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Nominal Loading Density (lbs/ft , wet basis): Usable Firebox Volume (ft 2.24 Target Load Weight (lbs): 26.88 Total Load Weight Range (lbs): 25.54...
  • Page 135 Run 4 DILUTION TUNNEL & MISC. DATA - ASTM E3053 / E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Test Start Time: Date: 4/11/2019 Test Type: Medium Fire Recording Interval (min): Pre-Test Post Test Avg. Barometric Pressure (in.
  • Page 136 Run 4 WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 137 Run 4 WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 138 Run 4 WOODSTOVE PREBURN DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Recording Interval (min): Run Time (min): Temperatures (°F) Elapsed Scale Stove Flue Draft Time Reading FB Left FB Right FB Back FB Top FB Bottom Surface...
  • Page 139 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 140 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 141 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 142 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 143 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 144 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 145 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 146 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 147 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 148 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 149 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 150 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 151 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 152 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 153 Run 4 BOX A TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Fuel Weight (lb) Temperature Data (°F) Particulate Sampling Data Dilution Orifice Elapsed Meter Gas Meter Sample Meter Pro.
  • Page 154 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 155 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 156 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 157 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 158 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 159 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 160 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 161 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 162 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 163 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 164 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 165 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 166 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 167 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 168 Run 4 BOX B TEST DATA - ASTM E3053 / ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Particulate Sampling Data Flue Gas Data Meter Gas Meter Orifice dH Flue Draft Elapsed Sample Meter Pro.
  • Page 169 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 437.8 438.0...
  • Page 170 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 430.4 429.4...
  • Page 171 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 440.2 442.2...
  • Page 172 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 392.2 390.2...
  • Page 173 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 322.6 321.4...
  • Page 174 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 295.8 295.8...
  • Page 175 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 287.8 287.6...
  • Page 176 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 280.6 280.4...
  • Page 177 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 272.2 272.4...
  • Page 178 Run 4 WOODSTOVE SURFACE TEMPERATURE DATA Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 Temperature Data (°F) Stove Surface Elapsed Time (min) FB Left FB Right FB Back FB Top FB Bottom Catalyst Exit Average 279.8 280.0...
  • Page 179 Run 4 LAB SAMPLE DATA - ASTM E2515 Client: Job #: 19-469 Model: I2450 Tracking #: 0025 Run #: Technician: Date: 4/11/2019 TRAIN A (1st Hour) Weights Filter, Probe, or Sample Component Sample Type O-Ring # Final, mg Tare, mg Particulate, mg T153/T159 175.9...
  • Page 180 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 2 Test Date: 4/9/2019 Wood Heater Run Notes Pre-Test Notes Pre-Test Start Time: 09:30 Air Control Setting: Fully Open Time Notes 0:00 Started PB with 1.8 lb, torch for 20 sec...
  • Page 181 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 2 Test Date: 4/9/2019 Test Photos Kindling Fuel Load Start-up Fuel Load High Fire Fuel Load Residual Start-up Fuel Coal Bed Technician Signature:...
  • Page 182 ASTM E3053 Wood Heater Run Sheets Client: FPI Job Number: 19-469 Tracking #: 0025 Model: I2450 Run Number: 2 Test Date: 4/9/2019 High Fire Fuel Loaded Med Fire Fuel Load Med Fire Fuel Loaded Med Fire Stirred Technician Signature: Date:...
  • Page 195 Run 1 Sample Calculations – ASTM E3053 & E2515 Client: Model: I2450 Run: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
  • Page 196 Run 1 – Weight of test fuel load, dry basis, lb (kg) Fldb ASTM E3053 equation (1) = Σ((M )(100/(100 + MC Fldb FLnwb Where, Weight of each test fuel piece, n, in test fuel load per 8.4.1, wet basis, lb (kg) FLnwb Average fuel moisture of test fuel piece, n, in test fuel load, % dry basis individual test fuel pieces that comprise the test fuel load, as applicable.
  • Page 197 Run 1 – Weight of start-up fuel, dry basis, lb (kg) SUdb ASTM E3053 equation (2) = (M )(100/(100 + MC SUdb SUwb Where, Total weight of start-up fuel pieces, wet basis, lb (kg) SUwb Average fuel moisture of the piece(s) from which start-up fuel was split, % dry basis Sample Calculation: = 4.03 SUwb...
  • Page 198 Run 1 - Weight of kindling, dry basis, lb (kg) ASTM E3053 equation (3) = (M )(100/(100 + MC Where, = Weight of kindling per 8.5.6, wet basis, lb (kg); Average moisture of kindling (may be assumed 10%), % dry basis. Sample calculation: 3.06 10.0...
  • Page 199 Run 1 - Total weight of all remaining fuel at end of high fire test run, lb (kg) FREHdb ASTM E3053 equation (4) FREHdb RSUBdb FLEHdb Where, = Weight of residual start-up fuel bed when high fire test load added, lb (kg) RSUBdb = Weight of unburned portion of test fuel load at the end of the high fire test run, lb (kg) FLEHdb...
  • Page 200 Run 1 – Dry burn rate for high fire test run, from time when test fuel load is added to end of test run, lb/h (kg/h) ASTM E3053 equation (6) = 60 (M )/θ FLdb FLEHdb Where, θ = Total duration of high fire test run, from time when test fuel load is added to end of test run, min. Sample calculation: 18.44 FLdb...
  • Page 201 Run 1 - Total weight of fuel burned during low or medium fire test run, lb (kg), dry basis TFBdb ASTM E3053 equation (7) TFBdb FLdb FREdb Where, = Total weight of fuel burned during low or medium fire test run, lb (kg), dry basis FLdb = Weight of remaining fuel at end of low or medium fire test run, lb (kg) FREdb...
  • Page 202 Run 1 BR - Dry burn rate for low and medium fire test runs, lb/h (kg/h) ASTM E3053 equation (8) 60 M TFBdb BR = θ Where, θ = Total test run duration for low or medium fire test run, min. Sample Calculation: = N/A - Applicable to Low/Medium Fire Tests Only TFBdb...
  • Page 203 Run 1 – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equation (9) Where: strav Adjustment factor for pitot tube center point reading = , ASTM E2515 Equation (1) scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec strav...
  • Page 204 Run 1 – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
  • Page 205 Run 1 – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) ∆�� �� ������ 13.6 �� = �� �� �� ��(������) �� �� �� Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
  • Page 206 Run 1 – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train A (first hour): Using equation for Train A (post-first hour): Train A aggregate: Using equation for Train B:...
  • Page 207 Run 1 - Concentration of particulate matter in tunnel gas, dry basis, corrected to STP, g/dscf ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train 1:...
  • Page 208 Run 1 – Total Particulate Emissions, g ASTM E2515 equation (15) Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr θ Total time of test run, minutes Sample calculation: For Train 1 = ( 0.000349 -...
  • Page 209 Run 1 PR - Proportional Rate Variation ASTM E2515 equation (16) Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith” time interval, dcf = Volume of gas sample as measured by dry gas meter, dcf = Average gas velocity in the dilution tunnel during the "ith"...
  • Page 210 Run 1 - Particulate emission rate for high fire test run, g/hr; ASTM E3053 equation (9) = 60(E /θ Where, Total particulate emissions for high fire test run including kindling and start-up, g θ Total duration of high fire test run, from ignition of kindling to end of test run, min. Sample Calculation: 11.32 θ...
  • Page 211 Run 1 - Particulate emission rate for low or medium fire test runs, g/hr ASTM E3053 equation (12) = 60(E /θ) Where, Total particulate emissions for low or medium fire test runs from Test Method E2515, g Sample Calculation: N/A - Applicable to Low/Medium Fire Tests Only θ...
  • Page 212 Run 2 Sample Calculations – ASTM E3053 & E2515 Client: Model: I2450 Run: Equations used to calculate the parameters listed below are described in this appendix. Sample calculations are provided for each equation. The raw data and printout results from a sample run are also provided for comparison to the sample calculations.
  • Page 213 Run 2 – Weight of test fuel load, dry basis, lb (kg) Fldb ASTM E3053 equation (1) = Σ((M )(100/(100 + MC Fldb FLnwb Where, Weight of each test fuel piece, n, in test fuel load per 8.4.1, wet basis, lb (kg) FLnwb Average fuel moisture of test fuel piece, n, in test fuel load, % dry basis individual test fuel pieces that comprise the test fuel load, as applicable.
  • Page 214 Run 2 – Weight of start-up fuel, dry basis, lb (kg) SUdb ASTM E3053 equation (2) = (M )(100/(100 + MC SUdb SUwb Where, Total weight of start-up fuel pieces, wet basis, lb (kg) SUwb Average fuel moisture of the piece(s) from which start-up fuel was split, % dry basis Sample Calculation: = N/A - Applicable to High Fire Tests Only SUwb...
  • Page 215 Run 2 - Weight of kindling, dry basis, lb (kg) ASTM E3053 equation (3) = (M )(100/(100 + MC Where, = Weight of kindling per 8.5.6, wet basis, lb (kg); Average moisture of kindling (may be assumed 10%), % dry basis. Sample calculation: = N/A - Applicable to High Fire Tests Only = N/A - Applicable to High Fire Tests Only...
  • Page 216 Run 2 - Total weight of all remaining fuel at end of high fire test run, lb (kg) FREHdb ASTM E3053 equation (4) FREHdb RSUBdb FLEHdb Where, = Weight of residual start-up fuel bed when high fire test load added, lb (kg) RSUBdb = Weight of unburned portion of test fuel load at the end of the high fire test run, lb (kg) FLEHdb...
  • Page 217 Run 2 – Dry burn rate for high fire test run, from time when test fuel load is added to end of test run, lb/h (kg/h) ASTM E3053 equation (6) = 60 (M )/θ FLdb FLEHdb Where, θ = Total duration of high fire test run, from time when test fuel load is added to end of test run, min. Sample calculation: = N/A - Applicable to High Fire Tests Only FLdb...
  • Page 218 Run 2 - Total weight of fuel burned during low or medium fire test run, lb (kg), dry basis TFBdb ASTM E3053 equation (7) TFBdb FLdb FREdb Where, = Total weight of fuel burned during low or medium fire test run, lb (kg), dry basis FLdb = Weight of remaining fuel at end of low or medium fire test run, lb (kg) FREdb...
  • Page 219 Run 2 BR - Dry burn rate for low and medium fire test runs, lb/h (kg/h) ASTM E3053 equation (8) 60 M TFBdb BR = θ Where, θ = Total test run duration for low or medium fire test run, min. Sample Calculation: 21.24 TFBdb...
  • Page 220 Run 2 – Average gas velocity in the dilution tunnel, ft/sec ASTM E2515 equation (9) Where: strav Adjustment factor for pitot tube center point reading = , ASTM E2515 Equation (1) scent Dilution tunnel velocity calculated after the multi-point pitot traverse at the center, ft/sec scent Dilution tunnel velocity calculated after the multi-point pitot traverse, ft/sec strav...
  • Page 221 Run 2 – Average gas flow rate in dilution tunnel, dscf/hr ASTM E2515 equation (3) Where: 3600 Conversion from seconds to hours (ASTM method uses 60 to convert in minutes) Water vapor in gas stream, proportion by volume; assume 2% Cross sectional area of dilution tunnel, ft Standard absolute temperature, 528 °R Absolute average gas static pressure in dilution tunnel, = P...
  • Page 222 Run 2 – Volume of Gas Sampled Corrected to Dry Standard Conditions, dscf m(std) ASTM E2515 equation (6) ∆�� �� ������ 13.6 �� = �� �� �� ��(������) �� �� �� Where: 17.64 °R/in. Hg Volume of gas sample measured at the dry gas meter, dcf Dry gas meter calibration factor, dimensionless Barometric pressure at the testing site, in.
  • Page 223 Run 2 – Total Particulate Matter Collected, mg ASTM E2515 Equation (12) Where: mass of particulate matter from probe, mg mass of particulate matter from filters, mg mass of particulate matter from filter seals, mg Sample Calculation: Using equation for Train A (first hour): Using equation for Train A (post-first hour): Train A aggregate: Using equation for Train B:...
  • Page 224 Run 2 - Concentration of particulate matter in tunnel gas, dry basis, corrected to STP, g/dscf ASTM E2515 equation (13) Where: Constant, 0.001 g/mg Total mass of particulate matter collected in the sampling train, mg Volume of gas sampled corrected to dry standard conditions, dscf m(std) Sample calculation: For Train 1:...
  • Page 225 Run 2 – Total Particulate Emissions, g ASTM E2515 equation (15) Where: Concentration of particulate matter in tunnel gas, g/dscf Concentration particulate matter room air, g/dscf Average dilution tunnel gas flow rate, dscf/hr θ Total time of test run, minutes Sample calculation: For Train 1 = ( 0.000076 -...
  • Page 226 Run 2 PR - Proportional Rate Variation ASTM E2515 equation (16) Where: θ = Total sampling time, min θ = Length of recording interval, min = Volume of gas sample measured by the dry gas meter during the “ith” time interval, dcf = Volume of gas sample as measured by dry gas meter, dcf = Average gas velocity in the dilution tunnel during the "ith"...
  • Page 227 Run 2 - Particulate emission rate for high fire test run, g/hr; ASTM E3053 equation (9) = 60(E /θ Where, Total particulate emissions for high fire test run including kindling and start-up, g θ Total duration of high fire test run, from ignition of kindling to end of test run, min. Sample Calculation: N/A - Applicable to High Fire Tests Only θ...
  • Page 228 Run 2 - Particulate emission rate for low or medium fire test runs, g/hr ASTM E3053 equation (12) = 60(E /θ) Where, Total particulate emissions for low or medium fire test runs from Test Method E2515, g Sample Calculation: 6.83 θ...
  • Page 259 Tested and listed to: DO NOT REMOVE THIS LABEL/NE LISTED FACTORY BUILT FIREPLACE INSERT OPTIONAL COMPONENT: FAN (142-917), ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS MINIMUM CLEARANCES TO PAS RETIRER CETTE ÉTIQUETTE CERTIFIED FOR USE IN CANADA AND U.S.A. DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD COMBUSTIBLE MATERIALS (MEASURED Jan Feb Mar Apr May June UNDER OR IN FRONT OF APPLIANCE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLI- MODEL/MODÈLE : I2450M FROM INSERT BODY) ANCE. DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO TESTED & LISTED BY /TESTÉ & APPROUVÉ : ADJACENT NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. RISK OF SMOKE AND FLAME SPILL- ULC-S628-93 (R1997) / UL-1482 - 2011 (R2015) 0219WN026S SIDEWALL A)12 in / 305 mm 2019 AGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. OPEN FEED DOOR TO FEED FIRE ONLY. RE- MANTEL B)14 in / 356 mm U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH 2020 PARTICULATE EMISSION STANDARDS USING CORD WOOD.” TESTED & LISTED PLACE GLASS ONLY WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN...
  • Page 260 CAUTION / ATTENTION Tested and listed to: DO NOT REMOVE THIS LABEL/NE LISTED FACTORY BUILT FIREPLACE INSERT OPTIONAL COMPONENT: FAN (142-917), ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS MINIMUM CLEARANCES TO PAS RETIRER CETTE ÉTIQUETTE CERTIFIED FOR USE IN CANADA AND U.S.A. DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD COMBUSTIBLE MATERIALS (MEASURED Jan Feb Mar Apr May June UNDER OR IN FRONT OF APPLIANCE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLI- MODEL/MODÈLE : HI2450M FROM INSERT BODY) ANCE. DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO TESTED & LISTED BY /TESTÉ & APPROUVÉ : ADJACENT NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD FIRE DIRECTLY ON HEARTH. RISK OF SMOKE AND FLAME SPILL- ULC-S628-93 (R1997) / UL-1482 - 2011 (R2015) 0219WN026S SIDEWALL A)12 in / 305 mm 2019 AGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. OPEN FEED DOOR TO FEED FIRE ONLY. RE- MANTEL B)14 in / 356 mm U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH 2020 PARTICULATE EMISSION STANDARDS USING CORD WOOD.” TESTED & LISTED PLACE GLASS ONLY WITH CERAMIC GLASS (5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN TO ASTM E3053.
  • Page 261 Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 0219WN026S FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 920-082c 06.30.21...
  • Page 262 Tested & listed to ASTM E3053. Model Regency I2450M 1.4 g /hr. “This manual describes the installation and operation of the Regency I2450M wood heater. This heater meets the 2020 U.S. Environmental Pro- tection Agency’s cord wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 14,200 Btu/hr.
  • Page 263 Faceplate and Trim Installation ........11 Flue Collar Removal and Installation ......12 Fan Installation ............14 Main Assembly & Options - I2450M ......25 Floor Protection ............15 Faceplates - I2450M ............26 Flue Baffle &Secondary Air Tube Installation ....15 Brick Panels - I2450M..........27 Glass Replacement .............15...
  • Page 264: Safety Label For I2450M

    Safety Label for I2450M This is a copy of the label that accompanies your Regency Insert. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 265 From back of faceplate (not shown) to fuel door opening 7" (178mm) Regency I2450M...
  • Page 266: Masonry And Factory Built Fireplace Clearances

    Width: 25" (635 mm) Depth: 17" (432 mm) Two faceplates are available to seal the fireplace opening: Standard W 40" (1 016 mm) x H 30" (762 mm) Oversize W 48" (1 219 mm) x H 33" (838 mm) Regency I2450M...
  • Page 267: Installation Into A Masonry Fireplace

    7. Do not connect the insert to a chimney system servicing another appliance or an air distribution duct. When referencing installation or connec- tion to masonry fireplaces or chimneys, the masonry construction must or shall be code complying. Regency I2450M...
  • Page 268: Altering The Fireplace

    9. Inserts that project in front of the fireplace must be supplied with appropriate supporting means. 10. Installer must mechanically attach the supplied label to the inside of the firebox of the fireplace into which the insert is installed. Regency I2450M...
  • Page 269: Installing Your Insert

    (2 per side) as shown in the diagrams. View from Rear of Insert Note: The grill has a front and rear, the holes on the front side have rounded edges and the rear holes have flat edges. Regency I2450M...
  • Page 270: Stainless Steel Smoke Deflector Installation

    WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure deflector is seated so bolts are situated at the top of the keyhole before tightening. 10 | Regency I2450M...
  • Page 271: Faceplate And Trim Installation

    1) Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts 7) The faceplate trim may be installed to the edge of may need to be squeezed with a pair of pliers first, the faceplate at this time. T o permanently mount the to help them stay in position). trim, drill two 5/32" diameter holes through the trim and side panels and screw the trim to the panels 2) Screw the side faceplate panels, (item A in the using the gold plated screws provided. diagram) one to each side. See diagram 1. Note: I t may be easier to install the insulation, faceplate top and faceplate trim with the unit pulled slightly away from the fireplace face. If this is done, be very careful not to disturb the connector when shifting the unit to its final position. 8) Now that your insert is installed, check once more that all the clearances from the unit to any combus- tible materials are correct as listed earlier. Regency I2450M...
  • Page 272: Flue Collar Removal And Installation

    Diagram 3. Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor. Front View 6. Manoeuver the baffle above the air tube and slide out. Diagram 3 Side View 12 | Regency I2450M...
  • Page 273 14. Use the two bolts, washers and lock wash- ers removed in step 7 and install them, tight- en down using the 1/2" socket to ensure the adapter is installed. Diagram 6 15. Reverse steps 6-3 to complete the installation. Regency I2450M...
  • Page 274: Fan Installation

    Wire98gr.eps updated Jan. 27/00 updated: Aug. 09/05 capitalized the word Nut Neutral Manual/ Green Live Ground Auto 120V AC Switch Switch 60 Hz Fan Thermodisc (normally open) Black Black Black Ground Blower/Fan Wiring Diagram 14 | Regency I2450M...
  • Page 275: Floor Protection

    Smoke Deflector 2. Slide the left baffle over the 2 remaining air tubes from the front and then push it to the back. 5. Reverse Step 1. Side View Regency I2450M...
  • Page 276: Wood Door & Handle Assembly

    (Refer to Diagram 1) Door hinges Wood handle Door Door handle Hinge Cap Cover Diagram 2 tooltip Note: Freestanding stove shown. Door as- sembly instructions are no different for the insert models. Diagram 3 16 | Regency I2450M 919-967a 04.03.19...
  • Page 277: Brick Installation

    Firebox Floor - install brick over LyTherm Sheet 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" c) Right and Left Side Firebricks 75) * Brick Partial: 1-1/4 x 4-1/2" x 2" 76) * Brick Partial: 1-1/4" x 2" x 9" Regency I2450M...
  • Page 278: Seasoned Wood

    Two dry pieces banged together sound hollow; wet pieces sound solid and dull. • Dry wood weighs much less than wet wood. • Split a piece of wood. If the exposed surface feels damp, the wood is too wet to burn. 18 | Regency I2450M...
  • Page 279: Operating Instructions

    12. For those units installed at higher elevations or your warranty! Regency I2450M...
  • Page 280: Fan Operation

    14. In the event of component failure, replace parts with only Regency listed parts. 15. Warning: do not abuse glass door such as striking or slamming shut. 20 | Regency I2450M...
  • Page 281: Maintenance

    4. A small hot fire is preferable to a large smoul- from rain or snow, delaying the seasoning process. dering one that can deposit creosote within the system. Regency I2450M...
  • Page 282: Do Not Burn

    FOR SUCH INSTALLATION. fumes. Burning coal, cardboard, or loose paper can produce soot, or large flakes of char or fly ash, causing smoke spillage into the room. Cleaning & Maintaining Your Wood Stove 22 | Regency I2450M...
  • Page 283: Vertical Stainless Deflector Replacement

    2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical deflector. 3. Repeat steps to install new vertical deflector. NOTE: ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO TOP OF FIREBOX. Note that the unit is not exactly as shown. Regency I2450M...
  • Page 284: Annual Maintenance

    When cleaning the chimney system the air tubes, baffles should be removed for ease of cleaning. See manual for details on removal. We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized brush and special vacuum cleaner designed to deal with fine particles. 24 | Regency I2450M...
  • Page 285: Parts List

    Main Assembly & Options - I2450M Part # Description Part # Description Part # Description 850-251 Door Assy - Large Black 23) 142-917 Fan Assembly 42) 163-931 Convection Grill - Nickel (Opt) 850-253 Door Assy - Large Nickel Accent...
  • Page 286: Faceplates - I2450M

    Faceplates - I2450M Part # Description 140-911 Faceplate & Trim Set - Regular 180-570 Black Trim Regular (set of 3) 285) * Trim Right Regular 286) * Trim Top Regular 287) * Trim Left Regular 288) * Faceplate Side Regular...
  • Page 287: Brick Panels - I2450M

    Brick Panels - I2450M Part # Description 180-960 Firebrick - Complete Set 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 75) * Brick Partial: 1-1/4 x 4-1/2" x 2" 76) * Brick Partial: 1-1/4" x 2" x 9"...
  • Page 288 Warranty protects against defect in manufacture or FPI factory assembled components only, unless herein specified otherwise. Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI’s option through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective part is returned to the distributor, dealer or agent for inspection if requested by FPI.
  • Page 289 Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this warranty. FPI is not liable for the removal or replacement of facings or finishing in order to repair or replace any appliance in the field.
  • Page 290 Customers should contact the authorized selling dealer to obtain all warranty and service. In the event the authorized selling dealer is unable to provide warranty / service, please contact FPI by mail at the address listed on the next page. Please include a brief description of the problem and your address, email and telephone contact information.
  • Page 291 Phone: Email: For purchases made in CANADA: For purchases made in the UNITED STATES: For purchases made in AUSTRALIA: FPI Fireplace Products Fireplace Products US, Inc. Fireplace Products Australia Pty PO Box 2189 PMB 125 International Ltd. 6988 Venture St.
  • Page 292 32 | Regency I2450M...
  • Page 293 Regency I2450M...
  • Page 294 34 | Regency I2450M...
  • Page 296 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial #: ____________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd. © Copyright 2021, FPI Fireplace Products International Ltd. All rights reserved.
  • Page 297 Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 0219WN026S FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 920-084e 06.30.21...
  • Page 298 Thank you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. “This wood heater has a manufacturer set minimum low burn rate that must not be altered.
  • Page 299 table of contents safety label operation Safety Label for HI2450 ..........4 Operating Instructions ..........27 Draft Control ..............27 First Fire ..............27 dimensions Fan Operation ..............28 Ash Disposal ..............28 Dimensions with Regular Faceplate ......5 Safety Guidelines and Warnings .........28 Dimensions with Oversize Faceplate ......6 maintenance installation Maintenance ..............29...
  • Page 300: Safety Label For Hi2450

    safety decal Safety Label for HI2450 This is a copy of the label that accompanies your Regency Insert. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
  • Page 301: Dimensions With Regular Faceplate

    dimensions Dimensions with Regular Faceplate " 591mm 11-3/8" [289 mm] " 800mm " " 1079mm 286mm 30" [762 mm] " " 1019mm 161mm ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency HI2450M...
  • Page 302: Dimensions With Oversize Faceplate

    dimensions Dimensions with Oversize Faceplate " 591mm " 800mm " " 1318mm 257mm " " 1229mm 186mm Regency HI2450M...
  • Page 303: Masonry And Factory Built Fireplace Clearances

    installation Masonry and Factory Built Fireplace Clearances The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below. Unit Adjacent Mantle ** Side Minimum Minimum Minimum To Top of Side Wall (to Top of Facing Facing Hearth...
  • Page 304: Installation Into A Masonry Fireplace

    installation Installation into a Masonry Chimney Specifications Draft is the force which moves air from the appliance up through the chimney. The amount of draft in your Fireplace chimney depends on the length of the chimney, local Before installing, check and clean your chimney geography, nearby obstructions and other factors.
  • Page 305: Installation Into A Factory Built Fireplace

    installation 1. When installed in a factory built fireplace, a Installation Into a Factory WARNING full stainless steel rigid or flexible flue liner is Built Fireplace mandatory, for both safety and performance Fire Risk. purposes. When a flue or liner is in use, the When lining air-cooled factory-built Regency inserts are constructed with the highest insert is able to breathe better by allowing a...
  • Page 306: Installing Your Insert

    installation WARNING STOP! PLEASE READ CAREFULLY. DO NOT LIFT OR PUSH THE UNIT FROM THE ASH- LIP, LEFT SIDE CAST or RIGHT SIDE CAST. THE CAST COMPONENTS ARE VERY FRAGILE. CASTING WILL CHIP OR BREAK. USE EXTREME CARE WHEN HANDLING. Installing Your Insert Your insert is very heavy and will require two or three people to move it into position.
  • Page 307: Stainless Steel Smoke Deflector Installation

    installation Stainless Steel Smoke Deflector Installation The stainless smoke deflector is located in the upper front area of the firebox. The deflector is held in place with 2 bolts Prior to the first fire, ensure deflector is seated properly and secured with 2 hand tightened bolts. Smoke deflector installed with 2 bolts.
  • Page 308: Standard Cast Faceplate Installation

    installation CAST FACEPLATE INSTALLATION Standard Cast Faceplate Installation HI300 Secure the Left and Right Side Faceplate to the f i rebox by align- FACEPLATE CONTENTS LIST ing the Mounting Holes with the Side Mounting Brackets taking Description care to align vertically while each side rests on the hearth. Secure using 1 bolt per bracket.
  • Page 309 CAST FACEPLATE INSTALLATION installation HI300 Slowly slide the Mantel Top forward until it stops. Retainer Top Faceplate Slide Mantel Mounting Plates Mount the Top Faceplate by carefully sliding the Mounting Plates on the Left and Right Side Faceplate thru the Retainers in the Top Faceplate.
  • Page 310 CAST FACEPLATE INSTALLATION installation HI300 RECOMMENDED MEASUREMENTS Location of Insulation: FOR SETTING SIDE CASTS Place 1 piece of Insulation behind the Mantel Top. Stop! Read Carefully. Cut the second piece of Insulation in half, then install behind both the Left and Right Sides as shown. Enamel &...
  • Page 311: Oversize Cast Faceplate Installation

    installation HI300 Oversize Cast Faceplate Installation OVERSIZE CAST FACEPLATE INSTALLATION Stop! Read Carefully. Enamel & Cast components are very fragile. Use extreme care when handling. 2) Secure the Left and Right Side Faceplate to the f i rebox by aligning FACEPLATE CONTENTS LIST the Mounting Holes with the Side Mounting Brackets taking care to Description...
  • Page 312 HI300 installation 5) Slowly slide the Mantel Top forward until it stops. 8) Carefully slide the Mantel Top back into position. Slide Mantel Top Slide Mantel Top back. 6) Place supplied gasket to bottom edge of top faceplate - continue gasket up each side at a 45°...
  • Page 313 HI300 installation SIDE CAST ADJUSTMENTS RECOMMENDED MEASUREMENTS FOR SETTING SIDE CASTS If unable to align side faceplate to unit and top Stop! Read Carefully. faceplate further adjustments need to be made, complete one Enamel & Cast components are very fragile. side at a time.
  • Page 314: Cast Grill Installation

    HI300 installation CAST GRILL HI300 Cast Grill Installation (300-981 Cast Black) / (300-985 Enamel Brown) GLASS REMOVAL TO INSTALL OPTIONAL DOOR CAST GRILL 1. To remove the glass, loosen the two 7/16" bottom retainer bolts but do not remove. 2. Remove the sides and top retainer and bolts highlighted in the diagram and carefully remove glass, it will fall towards you at the top.
  • Page 315: Fan Installation

    installation Fan Installation Installer: Please record unit serial number here before installing blower. Serial No.______________________________ Your fan should only be installed once the unit is in place in order to IMPORTANT prevent any damage to the fan. Ensure that the Left and Right Side Fan Facia do not 1.
  • Page 316: Power Outlet Conversion

    installation POWER OUTLET CONVERSION Power Outlet Conversion HI300 1) Remove the Phillips screw, located on the top of the 5) Raising the fan defl ector, pull the wire harness, switch fan housing, which attaches the fan defl ector to the plate, ground wire and thermodisc assembly from main fan body.
  • Page 317 POWER OUTLET CONVERSION installation HI300 9) Remove the wires one at a time from the existing switch plate, and attach each wire to the new switch plate, each wire in the same position as it was on the old switch plate (see wiring diagram). Discard the old switch plate.
  • Page 318: Flue Collar Removal And Installation

    installation Flue Collar Removal and Installation List of Tools required: 7. Take a ½” ratchet and remove the two bolts at back inside of the firebox. These - Pull rod (supplied with unit) bolts are used to secure the flue collar. Keep these and washers for re-install. - 1/2"...
  • Page 319 installation 12. Slide the unit back until the flue adaptor is slightly engaged. At this point it is recommended to level the unit. This will keep the adaptor from binding. 13. Insert the provided pull rod through the hole in the top center of the unit.
  • Page 320: Floor Protection

    installation Floor Protection 3. Tilt the left baffle up on top of the side chan- nel and it will leave enough room to position the right baffle in the same manner as Step Please check to ensure that your floor protection 1) above.
  • Page 321: Brick Installation

    installation Brick Installation Firebrick is included to extend the life of your stove and radiate heat more evenly. Check to see that all firebricks are in their correct positions and have not become misaligned during shipping. Install all firebricks (if bricks were removed at install) per the diagram below and place in their correct positions. Do not use a grate.
  • Page 322: Seasoned Wood

    installation Seasoned Wood Whether you burn wood in a fireplace, stove or insert, good quality firewood is the key to convenience, efficiency and safety. Wet wood and pieces that are not the right size and shape for your wood burner can be frustrating, burn inefficiently and deposit creosote that can fuel a dangerous chimney fire.
  • Page 323: Operating Instructions

    operating instructions Operating into sub-standard masonry fireplaces, drafting First Fire problems may occur. Consult an experienced Instructions dealer or mason on methods of increasing your When your installation is completed and inspected draft. you are ready for your first fire. With your unit now correctly installed and safety THIS UNIT IS DESIGNED TO BURN SEASONED 13.
  • Page 324: Fan Operation

    operating instructions Fan Operation Safety Guidelines 16. Do not store any fuel closer than 2 feet from and Warnings your unit. Do not place wood, paper, furniture, Automatic drapes or other combustibles near the appliance. To operate the fan - ensure switch is in AUTO mode. CAUTION: Do not use chemicals as fluids to start fire.
  • Page 325: Maintenance

    operating instructions Maintenance 5) The chimney and chimney connector should be inspected at least once every two months during the heating season to determine is a creosote It is very important to carefully maintain your fire- buildup has occurred. place stove, including burning seasoned wood and maintaining a clean stove and chimney system.
  • Page 326: Do Not Burn

    maintenance DO NOT BURN: CAUTION: DO NOT BURN GARBAGE • Treated wood OR FLAMMABLE LIQUIDS SUCH AS • Coal GASOLINE, NAPTHA OR ENGINE • Garbage OIL. SOME FUELS COULD GENER- • Cardboard ATE CARBON MONOXIDE AND ARE • Solvents VERY DANGEROUS. •...
  • Page 327: Door Gasket

    maintenance Glass Door Gasket Handle Replacement Replacement If the door gasket requires replacement, 7/8" diameter material must be used. A proper high 1) Open door. 1) Remove handle by unscrewing it from the latch. temperature gasket adhesive is required. A gasket repair kit, Part # 846-570 is available from your local 2) To replace the glass remove the 8 screws 2) Fit new door handle over latch and screw it in...
  • Page 328: Latch Adjustment

    maintenance Latch Adjustment The door latch may require adjustment as the door gasket material compresses after a few fires. Removal of spacers will allow the latch to be moved closer to the door frame, causing a tighter seal. 1) Remove the Latch Assembly from the unit by undoing the outer 2 3) Remove necessary amount of spacers sitting on the Mounting Bracket.
  • Page 329: Annual Maintenance

    maintenance Annual Maintenance Completely clean out entire unit Annually Inspect air tube and bricks Replace any damaged parts. Adjust door catch assembly If unable to obtain a tight seal on the door - replace door gasket seal. Readjust door catch after new gasket installed. Inspect condition and seal of: Glass Gasket Door Gasket...
  • Page 330: Vertical Stainless Deflector Replacement

    installation Vertical Stainless Deflector Replacement 7/16'' Nuts 7/16'' Bolts Slide left + down to remove. Reverse to replace. Vertical Deflector Remove 2 front air tubes 1. Remove 2 front secondary air tubes / vermiculite baffles as per page 24. 2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical baffle. 3.
  • Page 331: Main Assembly

    parts list Main Assembly Part # Description Not Shown in the drawing: 22) 300-551 Door Latch 942-681* Right Side Cast 23) 940-370/P Door Glass 300-981* Cast Grill 936-238 Side Cast Gasket 846-570 Door Gasket Kit 181-039 Wood Damper Handle 300-021 Flange Adaptor Glass Retainer 936-238...
  • Page 332: Standard Cast Faceplate

    parts list Standard Cast Faceplate Part # Description 300-921 Cast Faceplate - Metallic Black 300-925 Cast Faceplate - Timberline Brown 200) * Top Faceplate 201) * Left Side Faceplate 202) * Right Side Faceplate * Not available as a replacement part. 36 | Regency HI2450M...
  • Page 333: Oversize Cast Faceplate

    parts list Oversize Cast Faceplate Part # Description 300-971 Oversize Cast Faceplate - Metallic Black 300-975 Cast Faceplate - Timberline Brown 300) * Top Faceplate 301) * Left Side Faceplate 302) * Right Side Faceplate 303) 300-060 Mounting Plate LH 305) 300-061 Mounting Plate RH Not Shown in the Drawing...
  • Page 334: Brick Panels - Hi2450

    parts list Brick Panels - HI2450 Part # Description 180-960 Firebrick - Complete Set 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 75) * Brick Partial: 1-1/4 x 4-1/2" x 2" 76) * Brick Partial: 1-1/4" x 2" x 9" 38 | Regency HI2450M...
  • Page 335 notes Regency HI2450M...
  • Page 336: Warranty

    Warranty protects against defect in manufacture or FPI factory assembled components only, unless herein specified otherwise. Any part(s) found to be defective during the warranty period as outlined above will be repaired or replaced at FPI’s option through an accredited distributor, dealer or pre-approved and assigned agent provided that the defective part is returned to the distributor, dealer or agent for inspection if requested by FPI.
  • Page 337 Minor movement, expansion and contraction of the steel is normal and is not covered under the terms of this warranty. FPI is not liable for the removal or replacement of facings or finishing in order to repair or replace any appliance in the field.
  • Page 338 Customers should contact the authorized selling dealer to obtain all warranty and service. In the event the authorized selling dealer is unable to provide warranty / service, please contact FPI by mail at the address listed on the next page. Please include a brief description of the problem and your address, email and telephone contact information.
  • Page 339 Phone: Email: For purchases made in CANADA: For purchases made in the UNITED STATES: For purchases made in AUSTRALIA: FPI Fireplace Products Fireplace Products US, Inc. Fireplace Products Australia Pty PO Box 2189 PMB 125 International Ltd. 6988 Venture St.
  • Page 340 warranty 44 | Regency HI2450M...
  • Page 341 notes Regency HI2450M...
  • Page 342 notes 46 | Regency HI2450M...
  • Page 344 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial #: ____________________________________________________________ Printed in Canada Regency and Classic are trademarks of FPI Fireplace Products International Ltd. © Copyright 2021, FPI Fireplace Products International Ltd. All rights reserved.
  • Page 349 Dry Gas Meter Calibration Meter Manufacturer: Apex Model: Apex-AK-600 Lab ID #: Serial #: 810016 Calibration Date: 6/15/2018 Calibration Expiration: 6/15/2019 Barometric Pressure: 29.83 in. Hg Reference Standard DGM Unit Under Test Previous Calibration Manufacturer: Apex Date 1/18/2017 Model: SK25DA γ...
  • Page 355 Bulletin D-57 Model 1430 Microtector Electronic Point Gage ® Installation and Operating Instructions Model 1430 Microtector ® Portable • Three-point mounting, dual leveling Electronic Point Gage combines mod- adjustment, and circular level vial assure rapid setup ern, solid-state integrated circuit elec- •...