WARNING:
If the information in these instructions are not followed ex-
actly, a fi re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed
installer, service agency or the gas supplier.
Tested by:
908-785d
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.regency-fi re.com
U31 Gas Insert
MODELS: U31-NG2 Natural Gas U31-LP2 Propane
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.hampton-fi re.com
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your build-
ing.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you
supplier, call the fi re department.
www.excalibur-fi re.com
Owners &
Installation Manual
cannot reach your gas
03/05/08

Advertisement

Table of Contents
loading

Summary of Contents for FPI U31

  • Page 1 Owners & U31 Gas Insert Installation Manual MODELS: U31-NG2 Natural Gas U31-LP2 Propane FOR YOUR SAFETY WARNING: What to do if you smell gas: If the information in these instructions are not followed ex- Do not try to light any appliance actly, a fi...
  • Page 2: Unit Dimensions

    The FPI Gas Insert Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The models U31-NG2 and U31-LP2 of this series have been approved by Warnock Hersey for both safety and ef- fi...
  • Page 3: Table Of Contents

    Double Door Screen ..........15 Wiring Diagram ............16 Full Screen Front .............17 Hampton Cast Faceplate Installation ......19 Hampton Cast Faceplate Grill .........20 Excalibur Surround ..........21 Optional Wall Thermostat ........23 Optional Remote Control ........23 Final Check .............23 FPI U31-2 Gas Fireplace Insert...
  • Page 4: Safety Label

    This is a copy of the labels that accompany each NOTE: FPI units are constantly being im- U31-2 Gas Insert. We have printed a copy of the proved. Check the label on the unit contents here for your review. The safety label...
  • Page 5: Ma Code - Co Detector (For The State Of Massachuettes Only)

    (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. FPI U31-2 Gas Fireplace Insert...
  • Page 6: Installation

    1) The appliance installation must conform these instructions may also void with local codes or in the absence of local The FPI U31-2 may be installed and vented into your fi re insurance and/or warranty. codes, with CAN/CGA B149 (in Canada) any solid fuel fi...
  • Page 7: Installation Checklist

    Zero Clearance Kit are different. Please 13) Install Optional Remote Control and Optional Width (at front): 29" (737mm) refer to the Zero Clearance Kit Manual for Wall Thermostat, page 20. Depth: 16" (406mm) details. FPI U31-2 Gas Fireplace Insert...
  • Page 8: Conversion To Propane Kit

    INSTALLATION Conversion Kit from Natural Gas to Propane GAS CONNECTION Model #402-969 for: U31-NG2 Units GAS CONNECTION WARNING: Only persons licensed to work THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS with gas piping may make the FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! necessary gas connections to this appliance.
  • Page 9: Venting

    The maximum gas manifold pressure Periodically check that the vent is unrestricted Natural Gas 3.8" w.c. and an adequate draft is present when the unit Propane 11.0" w.c. is in operation. (See page 8 for spillage test.) FPI U31-2 Gas Fireplace Insert...
  • Page 10: Optional Brick Panel

    fl ue is blocked or has no "draw", the switch will automatically shut off the supply of gas within 5 - 10 minutes. Tampering with the switch can result in carbon monoxide (CO) poisoning and possible death. FPI U31-2 Gas Fireplace Insert...
  • Page 11: Log Set Installation

    The logs are fragile, handle with care - do not force into position. 2) Sprinkle the vermiculite around the fi rebox base. Take some of the embers (approx. 1/3 of the bag) and B)02-45 sprinkle over the vermiculite. FPI U31-2 Gas Fireplace Insert...
  • Page 12 C)02-56 and on top of the cutout on Log A)02-43. E)02-47 and push the bottom right edge against the bracket on the burner tray and the front edge of the rear burner. Notch D)02-46 F)02-48 A)02-43 C)02-56 Bracket B)02-45 Cutout FPI U31-2 Gas Fireplace Insert...
  • Page 13 fl ame hesitation, check that area for any blockage of the burner port. 13) Install fl ush glass and optional bay glass as per instruc- tions in this manual. G)02-44 A)02-43 C)02-56 B)02-45 G)02-44 FPI U31-2 Gas Fireplace Insert...
  • Page 14: Log Installation

    Diagram 5. 5) Connect the fan switch wires by taking the 11) Push the Regency logo plate into the two black and red wires with the male ends (in holes in the bottom left corner of the face- plate.
  • Page 15: Flush Louvers

    Hinge screws so the glass Location clips can be turned aside and t h e f l u s h g l a s s r e - B o t t o m moved. FPI U31-2 Gas Fireplace Insert...
  • Page 16: Wiring Diagram

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. FPI U31-2 Gas Fireplace Insert...
  • Page 17: Full Screen Front

    Bracket and slide under unit. Unit should touch tabs on Bottom Trim Bracket. Inside fl ange of Side Trim goes over the inner side of the unit fl ange. Push in Corners Bottom Trim Bracket FPI U31-2 Gas Fireplace Insert...
  • Page 18 6) The Top Frame is held in place by friction fi t, if the frame needs to be adjusted; bend the bracket accordingly. Top Frame FPI U31-2 Gas Fireplace Insert...
  • Page 19: Hampton Cast Faceplate Installation

    10) The power cord should be run behind the aligned. faceplate panel. 4) Use a measuring tape to ensure that the distance between the left and right side pieces is 28" (711mm). 28" FPI U31-2 Gas Fireplace Insert...
  • Page 20: Hampton Cast Faceplate Grill

    Slide side fi ller bracket place. into gap between glass and fi re box. 1) The U31 grill stop bracket is installed in the bottom left corner just under the fi rebox with the screw supplied as shown below. Grill Stop Bracket 2) Place top grill into brackets located inside top of fi...
  • Page 21: Excalibur Surround

    2 screws as shown in diagram 1. Repeat for right side. ON/OFF switch Fan Speed Switch wires to (Rear View) ON/OFF switch wires to Fan switch connectors for gas connection Self-adhesive wire clip Faceplate Trim Bracket Firebox Flange FPI U31-2 Gas Fireplace Insert...
  • Page 22 Faceplate. Push down to secure. Tug on the Sur- round to ensure it is securely locked in place. Faceplate Backside of Sur- round Shown Hooks Left Side Faceplate Bracket Trim Flange Faceplate Slots Faceplate Surround FPI U31-2 Gas Fireplace Insert...
  • Page 23: Optional Wall Thermostat

    10) Close the bottom louver assembly. 8) When lighting the appliance, the inside of 2) Connect the wires as per the wiring diagram the glass may fog up. This will burn off after above. a few minutes of operation. FPI U31-2 Gas Fireplace Insert...
  • Page 24: Shutdown Procedure

    It is not rates which can cause "ticking" and "cracking" unusual for the fan to make a "whirring" sound sounds. You should also be aware that as there FPI U31-2 Gas Fireplace Insert...
  • Page 25: Maintenance

    7/8" fl at glass gasket (Part # 936-243) for the and cleaned. Replace the embers but do Bay Front and for the Flush Front. not block the pilot. Top View of pilot fl ame FPI U31-2 Gas Fireplace Insert...
  • Page 26: Door Glass Replacement

    Flush Glass Replacement Panel in place. Slide old glass out of the side frames and replace 9) Remove the Fan Air Duct by removing 4 with new glass. screws, 2 per side. Aeration Adjustment Rod FPI U31-2 Gas Fireplace Insert...
  • Page 27: Parts List

    Flush Louvers (Set) - Gold/Black 402-920 Flush Louvers (Set) - Black 402-924 Flush Louvers (Set) - Steel/Black 25) 400-992 Bay Louvers (Set) - Gold/Black 400-990 Bay Louvers (Set) - Black 400-993 Bay Louvers (Set) - Steel/Black FPI U31-2 Gas Fireplace Insert...
  • Page 28 Pilot Assemby (LP) - 3 fl ame convertible top 65) * Burner Shroud Cover 67) * Firebox Base 68) * Valve Tray 69) 402-935 Log Set 402-572 Ember Package *Not available as a replacement part. FPI U31-2 Gas Fireplace Insert...
  • Page 29 402-943 Complete Double Screen Door 910-424 Extension Knob - Pilot ON/OFF 171) 512-546 Door Latch 910-426 Extension Knob - Flame HI/LOW 173) 430-133 Handle 402-956 Gold Trim Bay Front *Not available as a replacement part. FPI U31-2 Gas Fireplace Insert...
  • Page 30 Burner ON/OFF Switch 188) 910-330 Fan Speed Control (120 V) 190) * Screw #8 x 1/2" Black self-tapping 191) * Screw #8 x 1/2" Brass self-tapping 199) 948-220 Hampton Logo Plate *Not available as a replacement part. FPI U31-2 Gas Fireplace Insert...
  • Page 31 PARTS LIST FPI U31-2 Gas Fireplace Insert...
  • Page 32 205) * Flush Glass Frame 194) * Mounting Flange 207) 402-981** Cast Grill (Set) - Top & Bottom *Not available as a replacement part. ** Last digit of part number represents colour: 1=Black Metallic, 5=Enamel Brown FPI U31-2 Gas Fireplace Insert...
  • Page 33 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ FPI U31-2 Gas Fireplace Insert...
  • Page 34 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ FPI U31-2 Gas Fireplace Insert...
  • Page 35: Warranty

    It is the general practice of FPI to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect. The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.
  • Page 36 FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product. See the inside back cover for details. Register your Regency online at http://www.regency-fi re.com Register your Hampton online at http://www.hampton-fi re.com Register your Excalibur online at http://www.excalibur-fi...