FPI I2450M Manual page 210

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 1
PM
- Particulate emission rate for high fire test run, g/hr;
RH
ASTM E3053 equation (9)
PM
= 60(E
RH
TH
H2
Where,
E
=
Total particulate emissions for high fire test run including kindling and start-up, g
TH
θ
=
Total duration of high fire test run, from ignition of kindling to end of test run, min.
H2
Sample Calculation:
E
=
11.32
TH
θ
=
190
H2
PM
=
60( 11.32 /
RH
PM
=
3.58 g/hr
RH
PM
- Particulate emission factor for high fire test run, g/dry kg of fuel burned.
FH
ASTM E3053 equation (10)
PM
= E
/M
FH
TH
TFBHdb
Sample Calculation:
E
=
11.32
TH
M
=
9.18
TFBHdb
PM
=
11.32
FH
=
1.23 g/kg
PFS-TECO
)
190 )
/
9.18