TEST RESULTS - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
I2450
Run #:
4
Average Gas Velocity in Dilution Tunnel (ft/sec)
Average Gas Flow Rate in Dilution Tunnel (dscf/hr)
Particulate Concentration, dry-standard (g/dscf)
Difference from Average Total Particulate Emissions (g)
Difference from Average Emissions Factor (g/kg)
Quality Checks
Dual Train Precision
Filter Temps
Face Velocity
Leakage Rate
Ambient Temp
Negative Probe Weight Evaluation
Pro-Rate Variation
PFS-TECO
Burn Rate (kg/hr):
Total Sample Volume (ft
Average Gas Meter Temperature (°F)
Total Sample Volume (dscf)
Average Tunnel Temperature (°F)
Total Time of Test (min)
Total Particulate Catch (mg)
Total PM Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
Final Average Results
Total Particulate Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
HHV Efficiency (%)
LHV Efficiency (%)
CO Emissions (g/min)
Requirement
Each train within 7.5% of average emissions (in
grams), or emission factors within 0.5 g/kg
>80 °F, <90 °F
< 30 ft/min
Less than 4% of average sample rate
55-90 °F
<5% of Total Catch
90% of readings between 90-110%; none greater
than 120% or less than 80%
Page 2 of 50
Job #:
Tracking #:
Technician:
Date:
1.25
Ambient
Sample
Sample
Train A
3
)
53.274
70.888
80.9
91.0
51.997
68.644
0.2
6.3
0.0000038
0.0000918
0.33
7.46
0.04
0.95
-
0.76
-
0.49
-
0.05
6.97
0.89
0.71
66.4%
71.0%
1.35
Observed
See Above
Min: 82 / Max: 89
8.4
0 cfm
Min: 79 / Max: 85
Probe Catch Not
Negative
See Data Tabs
19-469
0025
ADK
4/11/2019
Sample
1st Hour
Train B
Filter
70.227
8.813
16.73
10804.9
104.8
87.1
66.067
8.593
106.8
471
5.3
2.8
0.0000802
0.0003259
6.48
3.48
0.83
3.48
0.66
-
-
0.49
-
0.05
Result
OK
OK
OK
OK
OK
OK
CHECK 10 MIN. INTERVAL
PRO-RATES