FPI I2450M Manual page 153

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 4
BOX A TEST DATA - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
I2450
Run #:
4
Elapsed
Gas Meter
Sample
Time
3
Rate (cfm)
(ft
)
(min)
462
69.520
0.153
463
69.674
0.154
464
69.823
0.149
465
69.977
0.154
466
70.127
0.150
467
70.282
0.155
468
70.432
0.150
469
70.584
0.152
470
70.735
0.151
471
70.888
0.153
Avg/Tot
70.888
0.151
PFS-TECO
Particulate Sampling Data
Dilution
Orifice
Meter
Tunnel dP
dH
Temp (°F)
(in H
O)
(in H
O)
2
2
0.070
2.28
91
0.068
2.28
91
0.066
2.29
91
0.067
2.29
91
0.068
2.28
91
0.068
2.29
91
0.070
2.29
91
0.073
2.27
91
0.071
2.28
91
0.067
2.29
91
0.069
2.25
91
Job #:
19-469
Tracking #:
0025
Technician:
ADK
Date:
4/11/2019
Fuel Weight (lb)
Meter
Pro. Rate
Scale
Vacuum
(%)
Reading
(in Hg)
-0.51
100
0.2
-1.48
102
0.2
-1.83
100
0.2
-2.82
103
0.1
-2.94
99
0.1
-0.45
103
0.1
-1.59
98
0.2
-2.4
97
0.1
-2.98
98
0.1
-1.93
102
0.0
-1.62
100
Page 24 of 50
Temperature Data (°F)
Weight
Dilution
Flue
Filter
Change
Tunnel
0
97
241
86
0
96
241
86
0
95
240
86
-0.1
95
239
86
0
97
238
86
0
96
238
86
0.1
95
239
86
-0.1
95
238
85
0
95
238
85
-0.1
95
237
85
107
327
86
Ambient
79
79
80
80
80
79
79
81
80
80
80.9

Advertisement

Table of Contents
loading