Emission testing instructions I2450
Volume: 2.24 cu.ft.
Low and Medium
High before Low and Medium – no sampling. Air set to High Setting
Fan on high at 20 min after loading main fuel load
Kindling – 3.0lb
Startup fuel – 4.0lb
Procedure
Start with a couple pieces of crumbled paper in between and 1.7 lbs kindling. Adjust the door opening
for less smoke and establish a good fire. Keep the door open in that position for 2 – 3 min.
At ~0.8lb load the remainder of the kindling fuel and 1.5lbs of start-up fuel close door soon after
loading.
At ~1b load remaining SU fuel and close the door right away after loading.
At low end of coal bed range load the high load. Close the door right away.
At 20 min turn on the fan on high.
Around 6 lbs adjust the load. Lift the unburned pieces out from the coals and bring unburned pieces to
center front to ensure full charcoalization.
Around 4.5 lbs, when everything is burned, and almost no flames left rake the coals, zero the scale and
follow the standard loading procedure.
Low and Medium test load
Load heavier logs to the sides.
Keep the door open a couple seconds so there is a strong fire going.
Air adjustment
Medium
At 8 min, close air ~halfway, at 11 min set the air to medium air setting.
Fan on low at 30 min