FPI I2450M Manual page 30

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 1
Heat Transfer Efficiency
Test Load Weight (dry kg)
VERSION:
PFS-TECO
B415.1 Efficiency Results
Manufacturer:
Model:
Date:
Run:
Control #:
Test Duration:
Output Category:
Test Results in Accordance with CSA B415.1-09
Overall Efficiency
Combustion Efficiency
Output Rate (kJ/h)
Burn Rate (kg/h)
Input (kJ/h)
MC wet (%)
MC dry (%)
Particulate (g )
CO (g)
Test Duration (h)
Emissions
g/MJ Output
g/kg Dry Fuel
g/h
g/min
lb/MM Btu Output
Air/Fuel Ratio (A/F)
2.2
FPI
I2450
04/08/19
1
19-469
163
High
HHV Basis
66.0%
98.0%
67.4%
36,487
2.77
55,274
7.52
18.32
22.43
11.32
257
2.72
Particulate
0.11
1.51
4.17
0.07
0.27
16.13
12/14/2009
Page 3 of 23
LHV Basis
70.6%
98.0%
72.1%
34,612
(Btu/h)
6.10
(lb/h)
52,433
(Btu/h)
16.58
dry lb
CO
2.59
34.16
94.60
1.58
6.03

Advertisement

Table of Contents
loading

Table of Contents