FPI I2450M Manual page 138

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 4
Client:
FPI
Model:
I2450
Run #:
4
Recording Interval (min):
Run Time (min):
Elapsed
Scale
Flue Draft
Time
Reading
(in H
(min)
(lbs)
88
7.3
-0.087
89
7.2
-0.069
90
7.1
-0.092
91
7.0
-0.085
92
6.9
-0.077
93
6.8
-0.077
94
6.7
-0.083
95
6.6
-0.082
96
6.6
-0.074
97
6.5
-0.075
98
6.4
-0.091
99
6.2
-0.076
100
6.0
-0.079
101
5.9
-0.078
102
5.6
-0.079
103
5.6
-0.068
104
5.4
-0.077
105
5.4
-0.080
106
5.3
-0.085
107
5.2
-0.075
108
5.1
-0.084
109
5.2
-0.078
110
4.9
-0.073
111
4.8
-0.077
112
4.9
-0.082
113
4.8
-0.063
114
4.7
-0.077
115
4.7
-0.076
116
4.6
-0.077
PFS-TECO
WOODSTOVE PREBURN DATA
1
116
FB Left FB Right FB Back
O)
2
607
558
604
557
602
556
600
554
597
553
596
552
594
551
592
549
590
548
588
547
586
545
583
544
582
543
581
542
581
542
583
541
584
541
585
540
587
539
588
539
588
537
588
536
588
535
586
533
585
530
584
529
582
527
580
524
578
523
Tracking #:
Technician:
Temperatures (°F)
FB Top
FB Bottom
383
403
382
397
382
391
381
386
381
380
380
373
379
367
379
364
379
358
378
356
377
351
378
346
378
344
378
344
378
347
378
350
379
355
379
359
380
360
380
362
381
364
381
362
382
362
383
359
383
357
383
353
384
348
383
345
383
341
Page 9 of 50
Job #:
19-469
0025
ADK
Date:
4/11/2019
Stove
Surface
Flue
Average
376
465.4
538
376
463.2
536
377
461.6
532
378
459.8
525
379
458.0
521
378
455.8
515
379
454.0
511
379
452.6
508
380
451.0
503
380
449.8
497
380
447.8
491
381
446.4
535
381
445.6
546
383
445.6
548
383
446.2
542
382
446.8
536
382
448.2
530
381
448.8
523
380
449.2
521
378
449.4
515
376
449.2
510
376
448.6
503
374
448.2
500
374
447.0
495
373
445.6
491
371
444.0
488
370
442.2
486
370
440.4
480
369
438.8
474
Ambient
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78

Advertisement

Table of Contents
loading