FPI I2450M Manual page 128

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 3.xlsm
Client:
FPI
Model:
I2450
Run #:
3
TRAIN A (1st Hour)
Incomplete Test Run - Results could not be computed, filter samples were not weighed
Sample Component
A. Front filter catch
B. Rear filter catch
C. Probe catch*
D. O-Ring catch*
TRAIN A (Post 1st hour)
Sample Component
A. Front filter catch
B. Rear filter catch
C. Probe catch*
D. O-Ring catch*
TRAIN B
Sample Component
A. Front filter catch
B. Rear filter catch
C. Probe catch*
D. O-Ring catch*
AMBIENT
Sample Component
A. Filter catch*
*Particulate catch that results in a negative number, is assumed to be zero for probes and O-rings, negative numbers for
filters are assumed to be part of the O-Ring weight.
PFS-TECO
LAB SAMPLE DATA - ASTM E2515
Filter, Probe, or
Sample Type
Filter
Filter
Probe
O-Ring
Filter, Probe, or
Sample Type
Filter
Filter
Probe
O-Ring
Train A Aggregate Total Particulate, mg:
Filter, Probe, or
Reagent
Filter
Filter
Probe
O-Ring
Filter, Probe, or
Reagent
Filter
Job #:
Tracking #:
Technician:
Date:
O-Ring #
Final, mg
T144
Sub-Total
Total Particulate, mg:
O-Ring #
Final, mg
T145
T146
15A
15A
Sub-Total
Total Particulate, mg:
O-Ring #
Final, mg
T147
T148
15B
15B
Total Particulate, mg:
O-Ring #
Final, mg
T149
Total Particulate, mg:
Page 19 of 19
19-469
0025
ADK/SJB
4/10/2019
Weights
Tare, mg
Particulate, mg
87.1
-87.1
0.0
0.0
0.0
-87.1
Weights
Tare, mg
Particulate, mg
86.3
-173.0
86.7
115628.9
0.0
3565.5
0.0
-173.0
-260.1
Weights
Tare, mg
Particulate, mg
86.4
-173.9
87.5
115903.2
0.0
3566.1
0.0
-173.9
Weights
Tare, mg
Particulate, mg
86.5
-86.5
-86.5

Advertisement

Table of Contents
loading

Table of Contents